5 in 1 Weather Meter with Cable Wind Speed Wind Direction Temperature Humidity Air Pressure Multifunction Wired Weather Sensor

2 sold in last 8 hours
mickcara
8575213294079
In stock
$259.00
Size Guide
$259.00
customers are viewing this product
Tags:
Features 1??Mini Design: The weather meter is a compact and highly integrated integrated sensor, which is smaller in design and equally powerful compared to traditional integrated environmental sensors. 2??Multifunction Monitoring: Measures 5 weather elements, including wind speed, wind direction, air temperature, humidity, and air pressure in a compact and lightweight design. 3??Wide Environmental Adaptability: Tested in harsh environments for temperature, waterproof, and salt spray resistance, suitable for various applications including agriculture, meteorology, forestry, and more. 4??Highly Accurate Data: Utilizes efficient filtering algorithm and special compensation technology for rain and fog weather, ensuring stable and consistent data readings. 5??Versatile Application: Ideal for wind monitoring in agriculture, meteorology, forestry, power plants, chemical factories, ports, railways, highways, and more, enabling appropriate response measures to be taken. Specifications Item Type: Wired Weather Meter Product Size: Approx. 165x70mm / 6.5x2.8in Gross Weight: 457g/16.1oz Material: ABS, Aluminum Alloy Communication Type: TTL (for Modbus RTU) Cable Length: 2 Meters Operating Environment: 0?100%RH, ?40?? to +60?? Protecting Grade: IP64 Built in Sensors: Wind Speed, Wind Direction, Temperature, Humidity, Air Pressure Widely Used: Wind Direction Measurement in Greenhouse, Environmental Protecting, Ship, Wharf, Aquaculture, Advertisement Gate, Meteorology, Ocean, Environment, Airport, Harbor, Laboratory, Industry, Agriculture and Transportation Environment. Wind Speed: 0 to 45m/s range, start wind speed ??0.8m/s, ??(0.5+0.02V)m/s accuracy, 0.1m/s resolution, 40mW power consumption Wind Direction: 0 to 359?? range, ??3?? accuracy, 1?? resolution, 40mW power consumption Atmospheric Temperature: -40 to 80??C range, ??0.3??C accuracy, 0.1??C resolution, 1mW power consumption Atmospheric Humidity: 0 to 100%RH range, ??5%RH accuracy, 0.1%RH resolution, 1mW power consumption Atmospheric Pressure: 300 to 1100hPa range, ??0.5 hPa (25??C) accuracy, 0.1 hPa resolution, 0.1mW power consumption Sensor Total Power Consumption: <150mW Wiring Diagram: TTL signal output, the sensor wire sequence is defined as follows: Red: power positive VCC Green: power negative GND Black: TXD Yellow: RXD Note: Make sure the wiring is correct before sending power. Communicating Protocol: All commands in the manual of weather meter are RTU protocol format commands. All have been configured at the factory, if you need to modify the protocol, refer to the relevant commands or ask for help. Baud rate 9600, 8 data bits, 1 stop bit, no check. 2 frames of data communicating interval of at least 500ms. The default address is 1, and the RTU communicating format is as follows: Number of address bytes: 1 byte Number of command bytes: 1 byte Number of register address bytes: 2 bytes Number of data bytes: N bytes Number of CRC check bytes: 2 bytes I.Register address: The weather meter can integrate five modes, namely wind speed, wind direction, air temperature, air humidity, and atmospheric pressure. Each sensor has its own register address. II.Configuration address and baud rate: The commands to write the device address are the same for the weather meter. III.CRC verification steps: 1. Preset the 16 bit register to hex FFFF, call this register the CRC register 2. Isolate the first 8 bit data with the lower bit of the CRC register, and put the result in the CRC register 3. Check the lowest bit by shifting the contents of the register one bit to the right (toward the lower bit) and filling the highest bit with a 0 4. If the lowest bit is 0: repeat step 3 (shift again) if the lowest bit is 1: the CRC register is iso orthogonal to the polynomial A001 (1010 0000 0000 0001) 5. Repeat steps 3 and 4 until it is shifted right 8 times so that the entire 8 bit data is all processed 6. Repeating steps 2 through 5 for the other 8 bit data 7. The final CRC register obtained is the CRC code (the CRC code obtained is low before high). Troubleshooting: The meter displays an incorrect value when TTL is output. The meter may not be able to acquire data correctly due to wiring problems or communicating serial port failure. Please check whether the wiring is correct and firm, whether the serial port is occupied, and whether the serial port setting is correct. Package List 1 x Wired Weather Meter

RETURNS POLICY

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

SHIPPING

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

How to choose the correct size:

Step 1 Please measure your foot length carefully.

Step 2 Please choose the correct size according to your foot length and chinese size.

For example, If your foot length is 255 mm , you should choose the size 8.

Step 3 If you\'re not sure of the correct size, you can click chat with us!

WHATSAPP:+8613625959351

Have Questions?Ask An Expert
5 in 1 Weather Meter with Cable Wind Speed Wind Direction Temperature Humidity Air Pressure Multifunction Wired Weather Sensor
You have successfully subscribed!