{"product_id":"100-new-original-electromagnetic-radiation-detector-tes-593r-tes593r-emf-meter-triaxial-data-logger-updated-from-tes-593","title":"100% New Original  Electromagnetic Radiation Detector TES-593R TES593R EMF Meter Triaxial Data Logger Updated from TES-593","description":"\u003cdiv\u003e\u003cspan\u003e\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     10 MHz to 8.0 GHz Frequency Range.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      For isotropic measurements of electromagnetic fields.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Non-directional (isotropic ) measurement with three-channel measurement probe.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      High dynamic range due to three-channel digital results processing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Configurable alarm threshold and memory function.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Easy to use\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     High frequency (RF) electromagnetic wave field strength measurement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Mobile phone base station antenna radiation power density measurement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Wireless communication applications (CW , TDMA , GSM , DECT).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Wireless LAN (Wi-Fi) detection, installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Camera, wireless bug finder.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Cellular\/Cordless phone radiation safety level.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Microwave oven leakage detection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Personal living environment EMF safety.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      RF power measurement for transmitters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   ELECTRICAL SPECIFICATIONS: \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Sensor Type\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Electric Field (E)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Frequency Range\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     10MHz to 8.0 GHz\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Directional Characteristic\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Isotropic, 3-dimensional\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Measurement Range (CW signal\u0026amp;gt;50MHz)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     20mV\/m to 108.0V\/m\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Absolute Error(@1V\/m and 50MHz)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     ± 1.0dB\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Frequency Response (taking into account typ. CAL factor)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     ± 1.0dB (50MHz to 1.9 GHz) , ±2.4dB(1.9GHz to 35GHz)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Isotropy Deviation\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Type. ±1.0dB f\u0026amp;gt;50 MHz\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Overload Limit\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     4.2W\/m2 (40 V\/m)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Temperature Response(0 to 50 )\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     ± 1.5dB\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Note\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Unless otherwise stated, all specifications hold under the following assumptions:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSinusoidal signals; device in far-field of a source; probe head pointing toward source; ambient temperature +23 ±3 ;relative air humidity 25% to 75%.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   GENERAL SPECIFICATIONS: \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Measurement Method\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Digital , triaxial measurement\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Directional Characteristic\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Isotropic, triaxial\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Measurement Range Selection\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     One continuous range\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Display Resolution\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     0.1mV\/m, 0.1 μA\/m, 0.1 μW\/m², 0.001 μW\/cm²\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Setting Time\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Typically 1s ( 0 to 90% of meas. value)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Display Refresh Rate\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Typically 400mS\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Display Type\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     LCD 4 digit\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Audible Alarm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Buzzer\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Measurement Units\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     mV\/m , V\/m , μA\/m , mA\/m , μW\/m² , mW\/m² , μW\/cm²\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Measurement Display Value\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Instantaneous measured value, maximum value or average value since power-on.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Measurement Average Time (In Per-set Steps)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     4s to 15 minutes\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Measurement Alarm Function\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Adjustable threshold with ON\/OFF\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Measurement Calibration Factor CAL\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Adjustable\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Manual Data Memory and Read Storage\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     99 sets ( only recall by meter )\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Battery\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     9V\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Battery Life\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u0026amp;gt;15 Hours\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Accessory\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Built-in Lithiumbatteries,Power Adapter,carrying case \u0026amp;amp; manual\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003c\/span\u003e\u003c\/div\u003e","brand":"mickcara","offers":[{"title":"TES593R","offer_id":41382252871817,"sku":"03028-1","price":699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0365\/2131\/2393\/files\/b714b5e47048c2df9b904cc0a9d0e935.jpg?v=1694853984","url":"https:\/\/mickcara.com\/fr\/products\/100-new-original-electromagnetic-radiation-detector-tes-593r-tes593r-emf-meter-triaxial-data-logger-updated-from-tes-593","provider":"mickcara","version":"1.0","type":"link"}