{"product_id":"10a-12v-24v-lcd-display-digital-temperature-controller-regulator-thermocouple-thermostat-sensor-with-ntc-10k-b3950-probe-cable","title":"10A 12V 24V LCD Display Digital Temperature Controller Regulator Thermocouple Thermostat Sensor With NTC-10K B3950 Probe Cable","description":"\u003cdiv\u003e\u003cspan\u003e\u003cp\u003e     \u003c\/p\u003e\n\u003cp\u003e             \u003c\/p\u003e\n\u003cp\u003e             \u003c\/p\u003e\n\u003cp\u003e   \u003c\/p\u003e\n\u003cp\u003e  \u003c\/p\u003e\n\u003cp\u003e           10A 12V 24V LCD Display Digital Temperature Controller Regulator Thermocouple Thermostat Sensor With NTC-10K B3950 Probe Cable\u003c\/p\u003e\n\u003cp\u003e           \u003c\/p\u003e\n\u003cp\u003e     \u003c\/p\u003e\n\u003cp\u003e     1.Description:\u003c\/p\u003e\n\u003cp\u003e     It is a digital temperature controller module.LCD display, very clear, easy to use, powerful.It can be widely used at Smart home,Industrial control,Automatic irrigation,Indoor ventilation.Protection equipment.\u003c\/p\u003e\n\u003cp\u003e     \u003c\/p\u003e\n\u003cp\u003e     2.Features:\u003c\/p\u003e\n\u003cp\u003e     1\u0026amp;gt;.LCD display;\u003c\/p\u003e\n\u003cp\u003e     2\u0026amp;gt;.Power-down memory function;\u003c\/p\u003e\n\u003cp\u003e     3\u0026amp;gt;.Emergency stop function;\u003c\/p\u003e\n\u003cp\u003e     4\u0026amp;gt;.Real-time display temperature;\u003c\/p\u003e\n\u003cp\u003e     5\u0026amp;gt;.Automatically save parameters;\u003c\/p\u003e\n\u003cp\u003e     6\u0026amp;gt;.Support UART Set;\u003c\/p\u003e\n\u003cp\u003e     7\u0026amp;gt;.Support Heating and Cooling work mode;\u003c\/p\u003e\n\u003cp\u003e     8\u0026amp;gt;.High temperature buzzer alarm;\u003c\/p\u003e\n\u003cp\u003e     9\u0026amp;gt;.Work status indicator;\u003c\/p\u003e\n\u003cp\u003e     10\u0026amp;gt;.Independent of parameters;\u003c\/p\u003e\n\u003cp\u003e     11\u0026amp;gt;.With case, beautiful and practical;\u003c\/p\u003e\n\u003cp\u003e     12\u0026amp;gt;.High precision;\u003c\/p\u003e\n\u003cp\u003e     13\u0026amp;gt;.Multiple parameters are displayed simultaneously.\u003c\/p\u003e\n\u003cp\u003e     \u003c\/p\u003e\n\u003cp\u003e     3.Parameters:\u003c\/p\u003e\n\u003cp\u003e     1\u0026amp;gt;.Product Name:Digital Temperature Controller\u003c\/p\u003e\n\u003cp\u003e     2\u0026amp;gt;.Product Number:XY-WT01\u003c\/p\u003e\n\u003cp\u003e     3\u0026amp;gt;.Working Voltage:DC 6V-30V\u003c\/p\u003e\n\u003cp\u003e     4\u0026amp;gt;.Control Load Current:10A(Max)\u003c\/p\u003e\n\u003cp\u003e     5\u0026amp;gt;.LCD refresh rate:0.5 second\u003c\/p\u003e\n\u003cp\u003e     6\u0026amp;gt;.Temperature Sensor:NTC-10K B3950\u003c\/p\u003e\n\u003cp\u003e     7\u0026amp;gt;.Test temperature: -50~110℃\u003c\/p\u003e\n\u003cp\u003e     8\u0026amp;gt;.Control precision:0.1℃\u003c\/p\u003e\n\u003cp\u003e     9\u0026amp;gt;.Sensor length: 0.5 meter\u003c\/p\u003e\n\u003cp\u003e     10\u0026amp;gt;.Sensor probe specifications:4*30mm Stainless steel\u003c\/p\u003e\n\u003cp\u003e     11\u0026amp;gt;.Physical dimension:79*44*26mm\u003c\/p\u003e\n\u003cp\u003e     12\u0026amp;gt;.Operating Humidity:5%~95%RH\u003c\/p\u003e\n\u003cp\u003e     \u003c\/p\u003e\n\u003cp\u003e     4.Work Mode:\u003c\/p\u003e\n\u003cp\u003e     1\u0026amp;gt;.’ H ’: Heating mode.\u003c\/p\u003e\n\u003cp\u003e     Relay will turn ON and the heating device starts to work when Current Temperature Value is less than Setting Temperature Value - Return Temperature Value.\u003c\/p\u003e\n\u003cp\u003e     Relay will turn OFF and the heating device stops to work when Current Temperature Value is more than Setting Temperature Value.\u003c\/p\u003e\n\u003cp\u003e     2\u0026amp;gt;.’ C ’: Cooling mode.\u003c\/p\u003e\n\u003cp\u003e     Relay will turn ON and the cooling device starts to work when Current Temperature Value is more than Setting Temperature Value + Return Temperature Value.\u003c\/p\u003e\n\u003cp\u003e     Relay will turn OFF and the cooling device stops to work when Current Temperature Value is less than Setting Temperature Value.\u003c\/p\u003e\n\u003cp\u003e     3\u0026amp;gt;.’ OPH ’: ON\/OFF delayed start.\u003c\/p\u003e\n\u003cp\u003e     The system starts timing 'T' when a normal heating or cooling operation is completed.The system will begin the next round of heating or cooling only after 'T'\u0026amp;gt;'OPH'.\u003c\/p\u003e\n\u003cp\u003e     4\u0026amp;gt;.’ OFE ’: Temperature correction function(-10.0~10.0℃).\u003c\/p\u003e\n\u003cp\u003e     If the module works for a long time, there may be deviations. Corrected by this function.\u003c\/p\u003e\n\u003cp\u003e     Actual Temperature Value = Current Temperature Value + Calibration Value.\u003c\/p\u003e\n\u003cp\u003e     5\u0026amp;gt;.’ ALA ’: Set high temperature alarm.\u003c\/p\u003e\n\u003cp\u003e     Module will turn on the sound and light alarm and relay will OFF at the same time when Current Temperature Value is more than Set Alarm Temperature Value.Any button to stop the sound and light alarm.\u003c\/p\u003e\n\u003cp\u003e     \u003c\/p\u003e\n\u003cp\u003e     5.Additional Features:\u003c\/p\u003e\n\u003cp\u003e     1\u0026amp;gt;. Set or read data by UART.\u003c\/p\u003e\n\u003cp\u003e     The parameters such as start temperature, stop temperature, temperature correction, etc. can be set through the UART.\u003c\/p\u003e\n\u003cp\u003e     2\u0026amp;gt;.Temperature real-time reporting.\u003c\/p\u003e\n\u003cp\u003e     The module transmits the detected temperature to the terminal through the UART at intervals of 1 s to facilitate data acquisition if the temperature reporting function is turned on.\u003c\/p\u003e\n\u003cp\u003e     3\u0026amp;gt;.Relay enable (default on).\u003c\/p\u003e\n\u003cp\u003e     If the relay enable is turned off, the relay remains off.\u003c\/p\u003e\n\u003cp\u003e     That is, the output state will never change, no matter what the measured temperature is.\u003c\/p\u003e\n\u003cp\u003e     4\u0026amp;gt;.Reset.\u003c\/p\u003e\n\u003cp\u003e     Press button ‘STOP’ and ‘SET’ for more than 3second at the same time to restore the factory settings.\u003c\/p\u003e\n\u003cp\u003e     \u003c\/p\u003e\n\u003cp\u003e     6.Set Parameter :\u003c\/p\u003e\n\u003cp\u003e     Long press:keep press button for more than 3second.\u003c\/p\u003e\n\u003cp\u003e     1\u0026amp;gt;.Set Working mode\/Setting temperature\/Return Temperature Value\u003c\/p\u003e\n\u003cp\u003e     1.1\u0026amp;gt;.Short press button 'SET' and enter the quick setting interface;\u003c\/p\u003e\n\u003cp\u003e     1.2\u0026amp;gt;.Switch the parameters that need to be set for Working mode\/Setting temperature\/Return Temperature Value by short press button 'SET'.\u003c\/p\u003e\n\u003cp\u003e     1.3\u0026amp;gt;.Modify the parameter value by button 'UP' or 'DOWN' after select parameter.Support short press\/long press;\u003c\/p\u003e\n\u003cp\u003e     1.4\u0026amp;gt;.Exit the quick setting interface and save the parameters by long press button 'SET' for 3second or continue 6S without any button operation.\u003c\/p\u003e\n\u003cp\u003e     NOTE:The Return Temperature Value display in the first line where the Current Temperature Value display position.\u003c\/p\u003e\n\u003cp\u003e     The Setting Temperature Value display in the second line after ‘H’ or ‘C’.\u003c\/p\u003e\n\u003cp\u003e     2\u0026amp;gt;.Set OPH\/OFE\/ALA\u003c\/p\u003e\n\u003cp\u003e     2.1\u0026amp;gt;.Long press button 'SET' and enter the parameter setting interface.\u003c\/p\u003e\n\u003cp\u003e     2.2\u0026amp;gt;.Switch the parameters that need to be set for OPH\/OFE\/ALA by short press button 'SET'.\u003c\/p\u003e\n\u003cp\u003e     2.3\u0026amp;gt;.Modify the parameter value by button 'UP' or 'DOWN' after select parameter.Support short press\/long press;\u003c\/p\u003e\n\u003cp\u003e     2.4\u0026amp;gt;.Exit the parameter setting interface and save the parameters by long press button 'SET' for 3second or continue 6S without any button operation.\u003c\/p\u003e\n\u003cp\u003e     2.5\u0026amp;gt;How to turn on the high temperature alarm ‘ALA’ (default off).Select ‘ALA’ interface,short press button ‘STOP’ to ON or OFF ‘ALA’.Set high temperature value by button ‘UP’ or ‘DOWN’ if turn ON ‘ALA’.If the high temperature alarm function is turned OFF, ‘ALA’ displays ‘----’ as a reminder.LCD will display ‘W’ if turn ON ‘ALA’.\u003c\/p\u003e\n\u003cp\u003e     2.6\u0026amp;gt;.How to enable delayed start ‘ OPH ’(default off).Select ‘ OPH ’ interface,short press button ‘STOP’ to ON or OFF ‘ OPH ’.Set delay time value by button ‘UP’ or ‘DOWN’ if turn ON ‘ OPH ’.If the delayed star function is turned OFF, ‘ OPH ’ displays ‘----’ as a reminder.LCD will display ‘h’ in last line and last bit if turn ON delayed start.\u003c\/p\u003e\n\u003cp\u003e     \u003c\/p\u003e\n\u003cp\u003e     7.Use steps:\u003c\/p\u003e\n\u003cp\u003e     1\u0026amp;gt;.Connect NTC sensor to Digital Temperature Controller;\u003c\/p\u003e\n\u003cp\u003e     2\u0026amp;gt;.Connect voltage to module;\u003c\/p\u003e\n\u003cp\u003e     3\u0026amp;gt;.Set parameters;\u003c\/p\u003e\n\u003cp\u003e     4\u0026amp;gt;.Remove input voltage;\u003c\/p\u003e\n\u003cp\u003e     5\u0026amp;gt;.Connect to load;\u003c\/p\u003e\n\u003cp\u003e     6\u0026amp;gt;.Connect voltage to module;\u003c\/p\u003e\n\u003cp\u003e     \u003c\/p\u003e\n\u003cp\u003e     8.UART communication and parameter settings\u003c\/p\u003e\n\u003cp\u003e     \u003c\/p\u003e\n\u003cp\u003e     The system supports UART data upload and parameter setting functions (TTL level);\u003c\/p\u003e\n\u003cp\u003e     UART: 9600, 8, 1\u003c\/p\u003e\n\u003cp\u003e     \u003c\/p\u003e\n\u003cp\u003e     9.Application:\u003c\/p\u003e\n\u003cp\u003e     1\u0026amp;gt;.Smart home\u003c\/p\u003e\n\u003cp\u003e     2\u0026amp;gt;.Industrial control\u003c\/p\u003e\n\u003cp\u003e     3\u0026amp;gt;.Automatic irrigation\u003c\/p\u003e\n\u003cp\u003e     4\u0026amp;gt;.Indoor ventilation\u003c\/p\u003e\n\u003cp\u003e     5\u0026amp;gt;.Self-made thermostatic control box\u003c\/p\u003e\n\u003cp\u003e     6\u0026amp;gt;.Equipment cabinet\u003c\/p\u003e\n\u003cp\u003e     7\u0026amp;gt;.Air conditioning system\u003c\/p\u003e\n\u003cp\u003e     8\u0026amp;gt;.Temperature control protection\u003c\/p\u003e\n\u003cp\u003e     9\u0026amp;gt;.Refrigerator\u003c\/p\u003e\n\u003cp\u003e     10\u0026amp;gt;.Freezer\u003c\/p\u003e\n\u003cp\u003e     11\u0026amp;gt;.Water heater\u003c\/p\u003e\n\u003cp\u003e     12\u0026amp;gt;.Hosts\u003c\/p\u003e\n\u003cp\u003e     13\u0026amp;gt;.Hatch control\u003c\/p\u003e\n\u003cp\u003e     \u003c\/p\u003e\n\u003cp\u003e     10.Note:\u003c\/p\u003e\n\u003cp\u003e     It is a relay output mode and cannot be used as a power module. It cannot output voltage. The load needs to be connected to a separate power supply.\u003c\/p\u003e\n\u003cp\u003e     \u003c\/p\u003e\n\u003cp\u003e    \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003c\/span\u003e\u003c\/div\u003e","brand":"mickcara","offers":[{"title":"000","offer_id":40750143307913,"sku":"02486-1","price":22.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0365\/2131\/2393\/products\/43a1ca596815fb0adfd149849b4b59c8.jpg?v=1662639660","url":"https:\/\/mickcara.com\/fr\/products\/10a-12v-24v-lcd-display-digital-temperature-controller-regulator-thermocouple-thermostat-sensor-with-ntc-10k-b3950-probe-cable","provider":"mickcara","version":"1.0","type":"link"}