{"product_id":"dso5102p-digital-oscilloscope-100mhz-2-channels-1gsa-s-7inch-tft-lcd-3","title":"DSO5102P Digital Oscilloscope 100MHz 2 Channels 1GSa\/s 7Inch TFT LCD","description":"Features:\n100MHz bandwidths.\n1GSa\/s Real Time sample rate.\nLarge (7.0-inch) color display, WVGA(800x480).\nRecord length up to 40K.\nTrigger mode: edge\/pulse width\/line selectable video\/slop\/overtime etc.\nUSB host and device connectivity, standard.\nMultiple automatic measurements.\nFour math functions, including FFTs standard.\nProvides software for PC real-time analysis.\nSpecifications:\nSize: 14 x 11x 32cm\/5.51 x 4.33 x 12.60inch\nWeight: 2900g\nModel\nDSO5102P\nAcquisition\nSample Rate\nReal-Time Sample: 1GS\/s\nEquivalent Sample: 25GS\/S\nAcquisition Modes\nNormal\nNormal data only\nPeak Detect\nHigh-frequency and random glith capture\nAverage\nWaveform Average, selectable 4.8.16.32,64,128\nInputs\nInputs Coupling\nAC, DC. GND\nInputs Impedance\n1M????2%ll20pF??3pF\nProbe Attenuation\n1X,10X\nSupported Probe Attenuation Factor\n1X,10X,100X,1000X\nMaximum Input Voltage\nCAT I and CAT II: 300VRMS (10x), Installation Category;\nCAT III: 150VRMS(1x);\nInstallation Category II: derate at20dB\/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.\nHorizontal\nSample Rate Range\n500MS\/S - 1GS\/S\nWaveform Interpolation\n(sin x)\/x\nRecord Length\n40K\nSEC\/DIV Range\nSample Rate and Delay Time Accuracy\n??50ppm (at over any ??1ms time interval)\nPosition Range\n20ns\/div to 80us\/div; (-8divx s\/div) to 40ms;\n200us\/div to 40s\/div; (-8divx s\/div) to 400s\nDelta Time Measurement\nAccuracy\n(Full Bandwidth)\nSingle-shot. Normal mode:?? (1 sample interval +100ppm x reading + 0.6ns); \u0026gt;16 averages:\n (1 sample interval + 100ppm x reading + 0.4ns);\nSample interval = s\/div \/ 200\nVertical\nVertical Resolution\n8-bit resolution, all channel sampled simultaneously\nPosition Range\n2mV\/div to 200mV\/div, ??2V 200mV\/div to 5V\/div, ??50V\nBandwidth\n100MHz\nRise Time at BNC( typical)\n3.5ns\nAnalog Bandwidth in Normal and Average modes at BNC or with probe. DC Coupled\n2mV\/div to 20mV\/div, ??400mV; 50mV\/div to 200mV\/div,??2V 500mV\/div to 2V\/div, ??40V; 5V\/div, ??50V\nMath\n+, - ,x,  \/, FFT\nFFT\nWindows: Hanning. Flatop. Rectamgular, Bartlett. Blackman; 1024 sample point\nBandwidth Limit\n20MHz\nLow Frequency Response (-3db)\n??10Hz at BNC\nDC Gain Accuracy\n??3%for Normal or Average acquisition mode. 5V\/div to 10mV\/div;\n??4% for Normal or Average acquisition mode. 5mV\/div to 2mV\/div\nDC Measurement Accuracy, Average Acquisition Mode\nWhen vertical displacement is zero, and N s16:?? (3% x reading + 0.1div+ 1mV)only 10mV\/div or greater is selected;\nWhen vertical displacement is not zero, and Ns16: ?? (3% x (reading + vertical position) +1% of vertical position + 0.2div); Add 2mV for settings from 2mV\/div to 200mV\/div; add 50mV for settings from 200mV\/div to 5V\/div\nVolts Measurement Repeatability, Average Acquisition Mode\nDelta volts between any two averages of si 6 waveforms acquired under same setup and ambient conditions\nTrigger System\nTrigger Types\nEdge. Video. Pulse. Slope. Overtime. Alternative\nTrigger Source\nCH1f CH2, EXT, EXT\/5, AC Line\nTrigger Modes\nAuto, Normal, Single\nCoupling Type\nDC, AC, Noise Reject, HF Reject. LF Reject\nTrigger Sensitivity (Edge Trigger Type)\nDC(CH1.CH2):\n1 div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full; DC(EXT):\n200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;\nDC(EXT\/5):\n1Vfrom DC to 100MHz; 1.75V from 100MHz to 200MHz;\nAC: Attenuates signals below 10Hz;\nHF Reject: Attenuates signals above 80kHz;\nLF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz\nTrigger Level Range\nCH1\/CH2: ??8 divisions from center of screen; EXT:??1.2V;\nEXT\/5:??6V\nTrigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ??20ns\nCH1\/CH2:0.2div x volts\/div within ??4 divisions from center of screen; EXT: ?? (6% of setting + 40mV);\nEXT\/5: ?? (6% of setting + 200mV);\nSet Level to 50%(typical)\nOperates with input signals ??50Hz\nVideo Trigger\nVideo Trigger Type\nCH1, CH2: Peak-to-peak amplitude of 2 divisions;\nEXT: 400mV;\nEXT\/5:2V\nSignal Formats and Field Rates. Video Trigger Type\nSupports NTSC, PAL and SECAM broadcast systems for any field or any line","brand":"mickcara","offers":[{"title":"Default Title","offer_id":44322772189321,"sku":"8795135327864","price":658.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0365\/2131\/2393\/files\/13xi7z.jpg?v=1750149182","url":"https:\/\/mickcara.com\/fr\/products\/dso5102p-digital-oscilloscope-100mhz-2-channels-1gsa-s-7inch-tft-lcd-3","provider":"mickcara","version":"1.0","type":"link"}