{"product_id":"etcr8100b-transformer-core-grounding-current-tester-large-diameter-clamp-ammeter-current-measuring-instrument","title":"ETCR8100B Transformer Core Grounding Current Tester Large Diameter Clamp Ammeter Current Measuring Instrument","description":"\u003cdiv\u003e\u003cspan\u003e\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e1.Technical Specifications:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFunction: transformer core grounding current test; AC leakage current, current, frequency, line test\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePower: DC6V alkaline dry battery LR6 1.5V × 4 (not included package)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTest method: clamping CT\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eJaw size: 80mm × 80mm (can be clipped φ80mm line, or 96mm × 4mm flat)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eRange: AC 0.00mA~30.0A\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eResolution: AC 0.01mA\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAccuracy: ±1.5%±3dgt (50Hz \/ 60Hz, 23°C±2°C, wire in the center)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFrequency: 20Hz~200Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDisplay mode: LCD: 128 points × 64 points\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eInstrument size: host 170mm × 75mm × 30mm; current clamp 194mm × 145mm × 40mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWeight: host 240g (with battery); current clamp 780g\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDisplay field: 44mm × 27mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eElectric field interference: about 10mA when the external electric field is close to 100A 10mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSampling rate: 3 times \/ sec.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eData storage: 100 groups (turn off or replace the battery without losing data)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWaveform indication: Yes, the display waveform is automatically amplified and cannot be judged based on the amplitude of this waveform.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eNumber setting: Test points can be numbered, for example: #001\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAuto power off: The instrument has five minutes to work without automatically turning off and selecting the function. The default is auto power off mode.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAlarm setting: Alarm threshold setting range: 10mA~30.0A\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAlarm indication: When the measured value exceeds the alarm threshold, the test data flashes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLine voltage: AC 600V or lower line test\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eOverflow display: Overrange overflow function: \"OL\" symbol display\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBattery voltage: When the battery voltage drops to 4.8V ± 0.1V, a low battery symbol appears, reminding you to replace the battery.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eRated current: 5mA in save mode, up to 20mA\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLead length: current clamp lead length is 2 m\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWorking temperature and humidity: -10 ° C ~ 40 ° C; 80% rh or lower\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eStorage temperature and humidity: -10 ° C ~ 60 ° C; 70% rh or lower\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDielectric strength: (between screw and housing) AC 2kV \/ rms\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor safety: IEC1010-1, IEC1010-2-032, pollution degree 2, CATIII 600V, IEC61326 (EMC standard)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAccessories: host: 1; current clamp: 1; RS232 communication line: one; software CD: 1; cloth: 1\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eNotes:the batteries not included package\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003c\/span\u003e\u003c\/div\u003e","brand":"mickcara","offers":[{"title":"ETCR1800B","offer_id":41383209468041,"sku":"03239-1","price":555.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0365\/2131\/2393\/files\/3a2828c82487781d98b8c41e6006bb6c.jpg?v=1694933892","url":"https:\/\/mickcara.com\/fr\/products\/etcr8100b-transformer-core-grounding-current-tester-large-diameter-clamp-ammeter-current-measuring-instrument","provider":"mickcara","version":"1.0","type":"link"}