{"product_id":"etcr8700-remote-power-off-leakage-alarm-monitor-with-485-communication-interface","title":"ETCR8700 Remote Power-off\/Leakage Alarm Monitor With 485 Communication Interface","description":"\u003cdiv\u003e\u003cspan\u003e\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     1.Brand introduction:  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  ETCRGuangzhou Iridium Tai Electronic Technology Co., Ltd., founded in 2000, is located in Zhixing Industrial Zone, Baiyun District, Guangzhou. At present, it has more than 70 employees and more than 3000 square meters of production plant. The company is committed to the development and production of high-end non-contact intelligent power testing instruments. The main products are: clamp grounding resistor, grounding resistance on-line tester, power quality analyzer, non-contact phase sequence meter, high-precision leakage current meter, high-voltage clamp current meter, phase volt-ampere meter, high-voltage transformer ratio tester, wireless clamp leakage current recorder, high-precision current clamp, open-close DC leakage current sensor, etc. The products are widely used in power, communications, and other fields. Military, petroleum, chemical, meteorological, railway, industrial and mining enterprises and other fields.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Iridium Technologies has a high-level technology research and development team, actively comply with IEC 1010 standards in product development and manufacturing, focusing on the development of safe, durable and accurate high-end digital detection products, and constantly upgrade existing products. The company also has an effective management team and dedicated excellent staff to ensure that our products are technologically advanced and of good quality. Enterprises have obtained dozens of national patents, such as clamp grounding resistor, ISO 9001:2008 quality management system certification, measuring instrument manufacturing license, is the National Metrology Verification regulations: JJG105410-2009 [clamp grounding resistor] participating in the formulation of units\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  2.Technical specifications:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e              Gong Neng\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Long-distance on-line current\/leakage current monitoring, leakage alarm, power outage alarm, power recovery power supply notification, active 10:00 a.m. to the administrator mobile phone to send daily information; other signals, equipment remote monitoring and alarm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Tong Dao\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     One current, one power supply, three extended input signals (DC0-12V analog voltage), three extended output control signals (on\/off: DC12V\/0V), a single maximum load of 500 mA, and three total output loads of the largest.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Power Source\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     External power adapter power supply: AC110V-240V to DC12V\/2A\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Built in battery\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Rechargeable lithium-ion batteries: 3.7V, 3000mAh, cycle charging times about 1000 times\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBatteries are charged continuously for about 15 hours\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Power reset\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     The GSM\/GPRS coMmunication module automatically resets and restarts the power supply once a day at 24 o'clock, and automatically passes the short message calibration time after restart. The starting time is about 1-3 minutes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             current range\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     0.00 mA~60.0 A AC (customized range 0~1000A according to demand)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Current resolution\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Minimum 0.01 mA AC\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Electric currentaccuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     2% RDG + 5 DGT\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Current shifting\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Fully automatic switching\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Detection speed\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     About 2 times \/ sec.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             CoMmunication mode\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     GSM, RS485\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             SIM card slot\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     External, easy to insert card\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             SIM card type\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     move2G,3G,4G\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             SIM card size\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Standard sizeCard:Big card\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             GSM antenna\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     50 Euro SMA Antenna\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Host size\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     100Mm* 73Mm* 35Mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             CT caliber\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     40mm (you can choose 10mm, 25mm, 80mm, etc.)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             CT size\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     95mm * 88mm * 31mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             CT leads\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Line length: 1mInterface: Three point fivemm audio plug\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Installation mode\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Guide rail fixed or screw fixed installation\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Installation dimension\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     The width of guide rail is 35 mm and the fixed screw hole is Three point five mm.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             RS485 interface\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     3.5mm- 3P Plug-in Terminal\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Extended interface\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     3.5mm- 12P Plug-in Terminal\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Extended input\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     IN1-IN3: Allow DC0-12V Analog Voltage Access\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Extended output\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Output voltage DC12V (on), or low voltage 0V (off)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Power failure alarm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     When the power supply of the monitored point is cut off or restored, the host of the monitored point sends a short message to the answering mobile phone.NumberSend out short message of power off alarm or resume power supply notification\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Leakage alarm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     When the current or leakage current of the monitored point exceeds the set alarm threshold, the host of the monitored point sends a short message to the answering mobile phone.NumberSend out Leakage Alarm SMS\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             LCD\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Display current or leakage current\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             CHARGE lamp\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Charging indicator light, red light when charging, green light when full\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             POWER OFF ALARM Lamp\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Power alarm indicator, always on when connected with external power supply, turn off external power supply to flicker\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             NET lamp\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     GSMNetwork indicator light, GSM module initially flickers slowly, GSM module always lights up when it works normally, and it flickers fast for 2 seconds when receiving and sending short messages.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Host power consumption\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Less than 2W\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Insulation strength\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     AC 2kV\/rms (between shell and screw)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Suitable for safety regulations\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     CAT III (600V)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Random attachment\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Host: 1 piece; CT sensor: 1 piece; Power adapter 12V\/2A: 1 piece; GSM antenna: 1 piece; Software CD: 1 piece\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003c\/span\u003e\u003c\/div\u003e","brand":"mickcara","offers":[{"title":"ETCR8700","offer_id":41382246809737,"sku":"03171-1","price":1322.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0365\/2131\/2393\/files\/81831ee6904590b53cb91972d4b7d05f.jpg?v=1694853677","url":"https:\/\/mickcara.com\/fr\/products\/etcr8700-remote-power-off-leakage-alarm-monitor-with-485-communication-interface","provider":"mickcara","version":"1.0","type":"link"}