{"product_id":"etcr9000b-current-leakage-high-voltage-clamp-current-meter","title":"ETCR9000B Current Leakage High Voltage Clamp Current Meter","description":"\u003cdiv\u003e\u003cspan\u003e\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e ETCR9000B Current Leakage High Voltage Clamp Meter\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Features:  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     ETCR9000B H\/L Voltage Clamp Meter has unique features of automatic plug function, specially designed and manufactured for high voltage current measurement; use the latest CT technology and integrated mask digital technology; composed of special high voltage detector, wireless receiver and high voltage insulation rods. Wireless transmission can receive the measured data by penetrating storey building barriers or 300 meters. If not use insulated rods, it can also used as high-precision low-voltage clamp meter and leakage current meter, can accurately measure the 0.0mA ~1000A current or leakage current.    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     The integrated design of clamp and lead zone of ETCR9000B H\/L Voltage Clamp Meter ensures uninterrupted year-round high precision, high reliability and high stability test.   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     The connection rods of ETCR9000B wireless high and low voltage clamp ammeter can be applied in high voltage line current measurement and online current measure below 60KV, also with the functions of peak value maintaining, data maintaining, data memory and infrared transmission, etc.  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     The special clamp ammeter can facilitate clamp to exit the tested lead by pressing or pulling back insulation bar, which is time efficient and convenient; widely used in power plant, substation, industrial and mining enterprise, inspection station, electrician maintenance department for current sensing and field working. It can also be used as high and low voltage changing ratio tester, that is, respectively test the first loop and secondary loop high and low voltage current, and then obtain the voltage change through manually calculation. Insulation rod has the characteristics of moisture resistance, high temperature resistance, impact resistance, bending resistance, high insulation and scalability, etc.     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Technical Specifications:  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                           Function      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  High voltage AC current measurement, low voltage AC current, current leakage measurement, online AC current measurement       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Power Supply      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  DC6V alkaline dry battery(1.5V AAA×4)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Test Mode      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Clamp CT, integral approach      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Transmission Mode      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Wireless transmission, the maximum distance of straight line transmission is about 30m      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Display Mode      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  4 bit LCD display, with backlight function      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          LCD Dimension      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  47mm×28.5mm      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Meter Dimension      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Width, height, thickness: 76mm×255mm×31mm      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Clamp Dimension      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  48mm      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Sampling Rate      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  2 times\/second      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Measurement Scope      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.0mA-1000A (50\/60Hz automatic)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Resolution      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.1mA      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Shift      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.0mA-1000A automatic shift      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Accuracy      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             (23C±5C, below 70%RH)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.0mA-299mA:      ±1%±3dgt       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          0.30A-9.99A:      ±1.5%±5dgt       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          10.0A-199.9A:     ±2%±5dgt      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          200A-399A:        ±2.5%±5dgt         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          400A-600A:        ±3%±5dgt         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          601A-1000A:       ±4%±5dgt        \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Line Voltage      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Below 60KV line test (with 5 insulation rods operation)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Data Memory      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  99 sets, memory process is shown by  MEM , full storage is shown by blinking  “FULL”      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          PEAK value maintaining      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Automatically maintain the high test value, in usual testing mode, press key HOLD till the lighting of PEAK, that is, start PEAK to maintain this function.        \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Data Hold      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  In usual testing mode, press HOLD key to keep data, shown by “HOLD”      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Data Access      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                   “MR” indication, can access to all data      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Overflow Display      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Over-range overflow function: shown in “OL  A”      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          No Signal Indication      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                   “no- -” is shown when receiver does not receive the dynamic display of signal transmission      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Automatic Shutdown      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  15 minutes after boot      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Battery Voltage      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  When battery voltage is lower than 4.8V, battery voltage is shown in low symbol to remind battery replacement      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Meter mass      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Detector: 335g (with battery), the total mass of meter: 2.5kg (including insulation rod and battery)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Working Temperature and Humidity      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  -25C-40C; below 80%Rh      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Storage Temperature and Humidity      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  -10C-60C; below 70%Rh      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Insulation Rod Dimension      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  φ32mm, 1m\/piece (5pieces)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Insulation Strength      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  AC 100kV\/rms (between the 5th insulation rod and high voltage current clamp core)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Structure      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Anti-drip type II      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Safety Provisions      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     IEC1010-1, IEC1010-2-032, Pollution Class 2, CAT III (600V), IEC61326(EMC standard)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Accessories      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Clamp: 1 piece; receiver: 1 piece; meter box: 1 piece; insulation rod (1m): 5 pieces; battery (alkaline battery AAA): 8 pieces (not included package)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003c\/span\u003e\u003c\/div\u003e","brand":"mickcara","offers":[{"title":"ETCR9000B","offer_id":41382254084233,"sku":"03072-1","price":1222.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0365\/2131\/2393\/files\/7d683b31f684b440243d77ac297ff96a.jpg?v=1694854125","url":"https:\/\/mickcara.com\/fr\/products\/etcr9000b-current-leakage-high-voltage-clamp-current-meter","provider":"mickcara","version":"1.0","type":"link"}