{"product_id":"etcr9100b-wireless-h-l-voltage-clamp-current-meter","title":"ETCR9100B Wireless H\/L Voltage Clamp Current Meter","description":"\u003cdiv\u003e\u003cspan\u003e\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eETCR9100B Wireless H\/L Voltage Clamp Current Meter\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIntroduction\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e ETCR9100B H\/L Voltage Clamp Meter specially designed and manufactured for high precision high voltage current measurement; use the latest CT technology and integrated mask digital technology; composed of special high voltage detector, wireless receiver and high voltage insulation rods. Wireless transmission can receive the measured data by penetrating storey building barriers or 30 meters. If not use insulated rods, it can also used as high-precision low-voltage clamp meter and leakage current meter, can accurately measure the 0.00mA ~600A current or leakage current. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e The integrated design of clamp and lead zone of ETCR9100B H\/L Voltage Clamp Meter ensures uninterrupted year-round high precision, high reliability and high stability test. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e The connection rods of ETCR9100B wireless high and low voltage clamp ammeter can be applied in high voltage line current measurement and online current measure below 69KV, also with the functions of peak value maintaining, data maintaining, data memory, etc. The special clamp ammeter can facilitate clamp to exit the tested lead by pressing or pulling back insulation bar, which is time efficient and convenient; widely used in power plant, substation, industrial and mining enterprise, inspection station, electrician maintenance department for current sensing and field working. It can also be used as high and low voltage changing ratio tester, that is, respectively test the first loop and secondary loop high and low voltage current, and then obtain the voltage change through manually calculation. Insulation rod has the characteristics of moisture resistance, high temperature resistance, impact resistance, bending resistance, high insulation and scalability, etc.  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e Technical Specifications\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Function      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               High voltage AC current measurement, low voltage AC current, current leakage measurement, online AC current measurement      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Power Supply     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               DC6V alkaline dry battery(1.5V AAA×4)(not included)     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Test Mode     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Clamp CT, integral approach     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Transmission Mode     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Wireless transmission, the maximum distance of straight line transmission is about 30m     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                      Display Mode     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               4 bit LCD display, with backlight function     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     LCD Dimension     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               47mm×28.5mm     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Meter Dimension     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               LWH: 68mm×245mm×40mm     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Clamp Dimension     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               33mm     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Sampling Rate     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               2 times\/second     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Measurement Scope     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               0.00mA-600A (50\/60Hz automatic)     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Resolution     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               0.01mA     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Shift     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               0.00mA-600A automatic shift     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Accuracy     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e           (23C±5C, below 70%RH)     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               0.00mA-100.0A:      ±1%±5dgt      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     100.0A-600.0A:      ±2%±5dgt     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Line Voltage     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Below 60KV line test (with 5 insulation rods operation)     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Data Memory     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               99 sets, memory process is shown by MEM , full storage is shown by blinking  FULL     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     PEAK value maintaining     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Automatically maintain the high test value, in usual testing mode, press key HOLD till the lighting of PEAK, that is, start PEAK to maintain this function.      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Data Hold     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               In usual testing mode, press HOLD key to keep data, shown by “HOLD”     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Data Access     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                “MR” indication, can access to all data     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Overflow Display     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Over-range overflow function: shown in “OL  A”     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Automatic Shutdown     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               15 minutes after boot     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Battery Voltage     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               When battery voltage is lower than 4.8V, battery voltage is shown in low symbol to remind battery replacement     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Meter Weight     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Detector: 335g (with battery), the total mass of meter: 2.5kg (including insulation rod and battery)     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Working Temperature and Humidity     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               -25C-40C; below 80%Rh     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Storage Temperature and Humidity     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               -10C-60C; below 70%Rh     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Insulation Rod Dimension     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               φ32mm, 1m\/piece (5pieces)     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Insulation Strength     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               AC 100kV\/rms (between the 5th insulation rod and high voltage current clamp core)     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Structure     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Anti-drip type II     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Safety Provisions     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    IEC1010-1, IEC1010-2-032, Pollution Class 2, CAT III(600V), IEC61326(EMC standard)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Accessories     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Clamp Meter : 1 piece; receiver: 1 piece; meter box: 1 piece; insulation rod (1m): 5 pieces; battery (alkaline battery AAA): 4 pieces(not included package)     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003c\/span\u003e\u003c\/div\u003e","brand":"mickcara","offers":[{"title":"ETCR9100B","offer_id":41382247596169,"sku":"03142-1","price":1211.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0365\/2131\/2393\/files\/86fbfdb3bb79e128299bd03174aba3a5.jpg?v=1694853679","url":"https:\/\/mickcara.com\/fr\/products\/etcr9100b-wireless-h-l-voltage-clamp-current-meter","provider":"mickcara","version":"1.0","type":"link"}