{"product_id":"fluke-568-2-2-in-1-ir-and-contact-thermometers-industial-ir-infrared-thermometer-35c-to-850c-fluke-568","title":"FLUKE 568-2 2-in-1 IR And Contact Thermometers Industial IR Infrared Thermometer -35C To 850C Fluke 568","description":"\u003cdiv\u003e\u003cspan\u003e\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFeature：\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e 1. Measurement range: -35°C-850°C\/-31°F to 1562°F (568-2) or -35°C-750°C\/-31°F to 1382°F (566-2)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e 2. Easy access to advanced features with softkey buttons and dot matrix display\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e 3. Can measure objects with longer distance and smaller volume, D:S ratio 55:1 (568-2) or 35:1 (566-2)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e 4. Compatible with all standard mini-connectors Type K thermocouples, with investment reserved for thermocouples\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e 5, adjustable emissivity function (built-in material table), allowing users to feel comfortable measuring a variety of surfaces\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e 6, storage of multiple data points (568-2 up to 99, 566-2 up to 50) for later download and call\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e 7, 2 levels of backlight brightness, easy to adapt to a variety of lighting conditions\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e 8. Audible and visual alarms timely prompt the user whether the measured value exceeds the set limit value\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e 9, quickly identify the problem through the minimum, maximum, average and DIF function\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e 10. The supplied K-type thermocouple bead probe facilitates immediate contact measurement\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e 11.1% accuracy of measurement allows users to rest assured to repair equipment\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e 12, multi-function interface is available in 6 languages\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e 13, adjustable emissivity settings improve the accuracy of the measurement\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e 14. Use the included FlukeView® Forms software to easily view data trends and analyze\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e 15, fast download the stored data through the USB interface\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e 16, no need to leave the scene, you can use the USB interface and laptop to immediately view the data\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e 17, digital thermometer through the USB interface to obtain power from the laptop, extending battery life\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e 18. The Fluke 568-2 can be mounted on a tripod and the infrared readings can be locked (equivalent to keeping the trigger pressed)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e 19. Comes with software and USB cable\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003especifications：\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Infrared Temperature Range    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            -40 to 1472°F (-40 to 800°C)    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Infrared Accuracy    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            \u0026amp;lt;32°F (0°C): ±(2.0°F (±1.0°C) + 0.1°\/1°C or °F)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u0026amp;gt;32°F (0°C): ±1% or ±2.0°F (±1.0°C), whichever is greater    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Display Resolution    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            0.1°F (0.1°C)    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Infrared Spectral Response    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            8 to 14 µm    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Infrared Response Time    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            \u0026amp;lt;500 msec    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Thermocouple Type-K Input Temperature Range    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            -454 to 2501°F (-270 to 1372°C)    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Thermocouple Type-K Input Accuracy    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            -454 to -40°F (-270 to -40°C): ±2°F + 0.2°\/1°F (±1°C + 0.2°\/1°C)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e-40 to 2501.6°F (-40 to 1372°C): ±1% or 2°F (±1% or 1°C)    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                D:S (Distance to Measurement Spot Size)    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            50:1    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Laser Sighting    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            Single-point laser \u0026amp;lt;1 mw output Class 2 (II) operation, 630 to 670 nm    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Minimum Spot Size    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            0.75\" (19 mm)    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Emissivity Adjustment    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Data Storage with Date\/Time Stamp    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            99 points    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                PC Interface and Cable    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            USB 2.0 with FlukeView® Forms software    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Hi\/Low Alarms    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            Audible and two-color visual    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Min\/Max\/Avg\/Dif    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            Yes    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Display    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            Dot matrix 98 x 96 pixels with function menus    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Backlight    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            Two levels, normal and extra bright for darker environments    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Trigger Lock    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            Yes    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Switchable Celsius and Fahrenheit    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            Yes    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Power    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            2 x AA\/LR6 Batteries and USB when used with a PC    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Battery Life    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            Laser and backlight on,12 hours used continuously\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLaser and backlight off, 100 hours used continuously    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Operating Temperature    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            32 to 122°F (0 to 50°C)    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Storage Temperature    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            -40 to 140°F (-20 to 60°C)    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Bead Thermocouple Type-K Range    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            -40 to 500°F (-40 to 260°C)    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Bead Thermocouple Type-K Accuracy    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            ±2.0°F (1.1°C) from 32 to 500°F (0 to 260°C), typically within 2.0°F (1.1°C) from -40 to 32°F (-40 to 0°C)    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003c\/span\u003e\u003c\/div\u003e","brand":"mickcara","offers":[{"title":"FLUKE 568-2","offer_id":41382146932873,"sku":"02953-1","price":999.0,"currency_code":"USD","in_stock":true}],"url":"https:\/\/mickcara.com\/fr\/products\/fluke-568-2-2-in-1-ir-and-contact-thermometers-industial-ir-infrared-thermometer-35c-to-850c-fluke-568","provider":"mickcara","version":"1.0","type":"link"}