   High Bandwidth 70MHz Oscilloscope, 1GS/s sample rate, and 6000 Counts DMM with analog bargraph.

  2M Memory Depth.

  Large 5.6 inch TFT Color LCD Display; High Resolution(640*480); Dual-Window Design --More clear, More Detailed

  One-touch automatic setup optimizes the position, range, timebase, and triggering to assure a stable display of virtually any waveform.

  Easy-to-use pop-up menu with built-in multi-language help system.

  32 Automatic Measurements.

  Waveform Math: Add, Subtract, Multiply, and Divide.

  Store and recall over.

  Automatic cursor tracking measurements.

  XY Mode.

  Built-in FFT function converts a time-domain signal into its frequency components to measure harmonic content and distortion in systems.

  Waveform Recorder to capture/replay input waveforms from CH1 and CH2 with a maximum record length of 1000 frames.

  Pass/Fail function compares a stored waveform to an unknown input.

  Average Mode for smoothing waveforms.

  Square Wave Output (2V, 1kHz) for probe adjustment.

  USB Host/Device 2.0 full-speed interface; support removeable disk;  LAN Option, easy to control by PC or long-distance.

  Dimensions (mm): 260(L)x220(W)x75(H), be carried easily.

 

 Specifications:

          Model

    DSO1072E

          Acquisition

          Sample Modes

    Real-Time Sample

          Acquisition Modes

    

          Normal

    Normal data only

          Peak Detect

    High-frequency and randon glith capture

          Average

    Wavefom Average, selectable 4,8,16,32,64,128

          Inputs

          Inputs Coupling

    AC, DC, GND

          Inputs Impendance

    1MΩ±2% 20pF±3pF

          Probe Attenuation

    1X, 10X

          Supported Probe Attenuation Factor

    1X, 10X, 100X, 1000X

          Maximum Input Voltage

    CAT I and CAT II: 300VRMS (10×), Installation Category;

CAT III: 150VRMS (1×)

          Horizontal System

          Sample Rate Range

    1GS/s

          Waveform Interpolation

    (sin x)/x

          Record Length

    2M

          SEC/DIV Range

    4ns/div~2000s/div, in a  2, 4, 8 sequence

          Sample Rate and

Delay Time Accuracy

    ±50ppm over any ≥1ms time interval

          Scanning Speed Range

    4ns/div to 8ns/div; (-8div x s/div) to 40ms;

20ns/div to 80μs/div;(-8div×s/div) to 40ms

200μs/div to 40s/div; (-8div×s/div) to 400s

          Delta Time Measurement Accuracy

(Full Bandwidth)

    Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);

>16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);

Sample interval = s/div ÷ 200

          Vertical System

          Vertical Resolution

    8-bit resolution, all channel sampled simultaneously

          Volts Range

    2mV/div to 100V/div at input BNC

          Bandwidth

    70MHz

          Rise Time at BNC( typical)

    5ns

          Analog Bandwidth in

Normal and Average

modes at BNC or with probe,

DC Coupled

    ±400V(100V/div-20V/div);

±50V(10V/div-5V/div)

±40V(2V/div-500mV/div);

±2V(200mV/div-50mV/div)

±400mV(20mV/div-2mV/div)

          Math

    +, -, *, /, FFT

          FFT

    Windows:Hanning, Flatop, Rectamgular, Bartlett, Blackman; 1024 sample point

          Bandwidth Limit

    20MHz

          Low Frequency Response (-3db)

    ≤10Hz at BNC

          DC Gain Accuracy

    ±3% for Normal or Average acquisition mode, 100V/div to 10mV/div.

±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div.

          DC Measurement Accuracy,

Average Acquisition Mode

    Measurement Type: Average of ≥16 waveforms with vertical position at zero

Accuracy: ± (3% × reading + 0.1div + 1mV) when 10mV/div or greater is selected.

Measurement Type: Average of ≥16 waveforms with vertical position not at zero

Accuracy: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div].

          Volts Measurement Repeatability,

Average Acquisition Mode

    Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions

      















RETURNS POLICY

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

SHIPPING

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

How to choose the correct size:

Step 1 Please measure your foot length carefully.

Step 2 Please choose the correct size according to your foot length and chinese size.

For example, If your foot length is 255 mm , you should choose the size 8.

Step 3 If you\'re not sure of the correct size, you can click chat with us!

WHATSAPP:+8613625959351

Avoir des questions? Demandez à un expert
HANTEK DSO1072E Oscilloscope/Recorder/DMM High Bandwidth 70MHz Oscilloscope 1GS/s Sample Rate
You have successfully subscribed!