Hantek Multifunction Process Calibrator HT824 High-precision Five And A Half Signal Source Multimeter Voltage Flow Resistance

2 sold in last 8 hours
mickcara
02950-1
In stock
$2,333.00
Size Guide
Color *
000
$2,333.00
customers are viewing this product
Tags:


Features:

      HT824 multifunctional process calibrator has high accuracy, high stability, can be widely used in site calibration of industry instruments and equipment in laboratory. Powerful functions, it can simulate to output voltage in millivolt and volt, current in milliampere, and many types of electric signals needed by the measurement and control during industry control process. It can also test or simulate kinds of TC and RTD signals.

   5 1/2 digit input/output display.

   Manual/auto cold junction compensation and setting.

   The temperature value can be directly measured/output.

   Auto power off when the voltage of battery is low.

   Apply advanced built-in battery management system. 7.4V/7800mAh lithium battery, which can easily last for over 8 hours during site measurement work.

   Auto triangular wave/step wave signal output.

   It can store 8 sets of measurement and output data, and recall it to display. All the setting value and the function in the last operation can be saved automatically after power-off.

   The screen shows the connection diagram of probes and plugs to avoid wrong operation. It has backlight.

   The output has manual/auto step and slope output function. It can arbitrarily set the value of 0%, 25%, 100% in the range of signal output to test the response speed of transmitter.

   Application field: measurement and calibration of instruments, maintenance and overhaul of temperature instruments, automatically maintenance and overhaul, project construction debugging, detection and diagnosis of control system signal source, configuration of site instrument repairmen room, matching of the thermal engineering laboratory in electric power industry.

  

 

          Model

    HT824

          DC Voltage Measurement

          Range

    0-30.000V(Upper part of screen)*1

    0-24.000V(Bottom of screen)*2

    0-90.000mV

          Resolution

    0.001V

    0.001V

    0.001mV

          Accuracy

    0.1%+5

    0.05%+5

    0.05%+5

          *1和*2:Input resistance is greater than 1MΩ

          DC Voltage Output

          Range

    0—20.000V

    0—90.000mV

          Resolution

    0.001V

    0.001mV

          Accuracy

    0.05%+5

    0.05%+5

          Millivolt measurement and output*1

          Range

    -10.000mV—80.000mV

          Resolution

    0.001mV

          Accuracy

    0.05%+5

          *1 Press TC(16) to select this function. Signal is at thermocouple micro input/output TC port.

          DC Current (milliampere) Measurement

          Range

    0—24.000mA(Upper part of screen)*1

    0—24.000mA(Bottom of screen)*2

          Resolution

    0.001mA

    0.001mA

          Accuracy

    0.05%+5

    0.05%+5

          DC Current (milliampere) Output

          Range

    0—24.000mA

          Resolution

    0.001mA

          Accuracy

    0.05%+5

          SIMU(Simulation)When outputting current, external voltage is greater than 12V, less than 28V.

          SOUR(Source)When outputting current, signal driving ability is 1000Ω in 20mA.

          Resistance Measurement

          Ohm Range

    

    0—400.00Ω

    400.0—4000.0Ω

          Accuracy ±Ω

    4 Wire(4W)

    0.02%+5

    0.02%+5

          2 Wire(2W)and 3 Wire(3W)

    0.05%+5

    0.05%+5

          Excitation current:0.2mA。

          Maximum input voltage:30V。

          2 Wire:Do not include wire resistance.

          3 Wire:Assume to use the matched testing wire, the total resistance cannot be greater than 100Ω.

      

          Resistance output

          Range

    5.00Ω―400.00Ω

    400.0―1500.0Ω

          Excitation current from the measurement instrument

    0.15mA-2mA

    0.05mA-0.8mA

          Accuracy ±Ω

    0.05%+5

    0.05%+5

          Resolution

    0.1Ω

    0.1Ω

          Temperature - Thermocouple

          Type

    Range

    Resolution

    Measurement and output accuracy ±℃

          S

    -50.0℃ to 0℃

    0.1℃/0.1℉

    2℃

          0℃ to 500.0℃

    0.1℃/0.1℉

    1.5℃

          500.0℃ to 1760.0℃

    0.1℃/0.1℉

    1.3℃

          R

    -50.0℃ to 0℃

    0.1℃/0.1℉

    2℃

          0℃ to 500.0℃

    0.1℃/0.1℉

    1.5℃

          500.0℃ to 1760.0℃

    0.1℃/0.1℉

    1.3℃

          B

    200℃ to 800℃

    1℃/1℉

    2.5℃

          800℃ to 1800℃

    1℃/1℉

    2.3℃

          K

    -200.0℃ to 1370.0℃

    0.1℃/0.1℉

    1.3℃

          N

    -200.0℃ to 1300.0℃

    0.1℃/0.1℉

    1.3℃

          E

    -200.0℃ to 1000.0℃

    0.1℃/0.1℉

    1℃

          J

    -200.0℃ to 1200.0℃

    0.1℃/0.1℉

    1℃

          T

    -200.0℃ to 400.0℃

    0.1℃/0.1℉

    1℃

          Thermocouple adopts ITS-90

          If open cold junction compensation, there should be additional ±0.5℃

      

          Temperature – Thermal resistance

          Type

    

    Accuracy ±℃

          Range

    Testing 4 wire ℃

    Testing 2 wire and 3 wire ℃

    Output ℃

          Pt100-385

    -200.0℃-850.0℃

    0.8℃

    1℃

    0.8℃

          Pt100-3926

    -200.0℃-850.0℃

    0.8℃

    1℃

    0.8℃

          Pt100-JIS

    -200.0℃-850.0℃

    0.8℃

    1℃

    0.8℃

          Pt200-385

    -200.0℃-250.0℃

    0.7℃

    0.8℃

    0.7℃

          250.0℃-630.0℃

    1.3℃

    2.1℃

    1.3℃

          Pt500-385

    -200.0℃-500.0℃

    0.8℃

    1.1℃

    0.8℃

          500.0℃—630.0℃

    1℃

    1.5℃

    1℃

          Pt1000-385

    -200.0℃-100.0℃

    0.7℃

    0.7℃

    0.8℃

          100.0℃-630.0℃

    0.7℃

    0.8℃

    0.8℃

          Cu100

    -50.0℃-150.0℃

    1℃

    1.2℃

    1℃

          Cu50

    -50.0℃-150.0℃

    1℃

    1.2℃

    1℃

          Resolution: 0.1°C, 0.1°F

          Allowable excitation current(output): Pt100-385, Pt100-392, Pt100-JIS, Pt200-385:0.15 to 3.0 mA

          Pt500-385:0.05 to 0.80mA;Pt1000-385:0.05 to 0.40mA

          2 Wire:Do not include wire resistance.

          3 Wire:Assume to use the matched testing wire, the total resistance cannot be greater than 100Ω.

          Comprehensive Index

          Operation temperature

    0℃ to 50℃

          Storage temperature

    -20℃ to 70℃

          Operation  height

    Average elevation 3000 meters below.

          Relative humidity (No condensation relative work humidity %)

    75%(30℃ to 40℃)

          45%(40℃ to 50℃)

          35%(50℃ to 55℃)

          <10℃, no control

          Stability

    Out of the range 23±5℃, each degree increase ±0.005% of the range.

          Vibration

    The random vibration, 2g,5 to 500Hz

          Security

    EN 61010-1:1992

          Protection Level

    Pollution grade Ⅱ


RETURNS POLICY

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

SHIPPING

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

How to choose the correct size:

Step 1 Please measure your foot length carefully.

Step 2 Please choose the correct size according to your foot length and chinese size.

For example, If your foot length is 255 mm , you should choose the size 8.

Step 3 If you\'re not sure of the correct size, you can click chat with us!

WHATSAPP:+8613625959351

Avoir des questions? Demandez à un expert
Hantek Multifunction Process Calibrator HT824 High-precision Five And A Half Signal Source Multimeter Voltage Flow Resistance
You have successfully subscribed!