HVP-40 Digital Multimeter High Voltage Probe 0~40KV 1000:1


 Specification:

               

           Before taking any measurements, first connect the alligator clip of this probe to earth ground and make sure connection is electrically good.     

           Input impedance: 1000Mohm     

           Division Ratio: 1000: 1     

           MAX. Test Voltage     

           DC : 0 ~ 40KV     

           AC : 1 ~ 28KV ( 50 / 60 Hz )     

           Safety APPL.     

           EN61010 UL3111-1 TUV / GS     

           IEC 1010 CAT II Pollution 2     

           Polarity: Positive / Negative     

           Accuracy     

           DC :+/- 1% to 20KV     

           +/- 2 % to 40KV     

           AC : - 5 % to - 10 % ( 1 ~ 28KV ; 50 / 60Hz )     

           Temperature Coefficient:<= 200ppm /C     

           Maximum loading Current:<= 40μA ( at 40KV DC )     

           Maximum loading power:<= 1.6 watt     

           Operating temperature:0 ~ + 50 C     

           Storage temperature:- 20 ~ + 70C     

           Ground Lead length:90cm ( 3ft )     

           Output cable length:100cm ( 3.3ft )     

           For:DMM     

           Output Division:1V / 1KV     

           Dimensions:340mm x 80ψ     

           Weight: about 300g     

           Remark: For 10Mohm input impedance     

           DMM ( Accuracy < 0.5 % ) only.     

    

      



      Model number

    HVP-40

       Input Resistance

    1000MΩ;

       Attenuation Ratio

    1000:1

       Max. Operation Voltage

    DC  0~ ± 40KV

        AC  1~ 28KV(50/60Hz)

       Safety APPL

    EN61010 , UL3111-1 , TUV-GS

        IEC1010 CAT II Pollution 2

       Polarity 

    Positive/negative are measurable

       Accuracy

    DC:± 1% to 20  KV , ± 2% to 40  KV

        AC:- 5% to - 10% at 50 ~ 60Hz

       Temperature Coefficient

    ≤ 200ppm /°C

       Maximum Loading Current

    ≤ 40μA ( at 40KV DC )

       Maximum Loading Power 

    ≤ 1.6 watt

       Operating Temperature

    0°C ~ + 50°C

       Designated link

         

    

    10MΩ input impedance DMM

       Meter output instructions

    X 1000,     1V→1000V

       10V→10KV

   



 


RETURNS POLICY

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

SHIPPING

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

How to choose the correct size:

Step 1 Please measure your foot length carefully.

Step 2 Please choose the correct size according to your foot length and chinese size.

For example, If your foot length is 255 mm , you should choose the size 8.

Step 3 If you\'re not sure of the correct size, you can click chat with us!

WHATSAPP:+8613625959351

Avoir des questions? Demandez à un expert
HVP-40 Digital Multimeter High Voltage Probe 0~40KV 1000:1
You have successfully subscribed!