HW-300S Auto Digital Thickness Gauge Car Paint Thickness Meter Coating Thickness Gauge Measuring Tool Accessories 40%Off

2 sold in last 8 hours
mickcara
a01248-1
In stock
$38.00
Size Guide
Color *
Orange
Black
$38.00
customers are viewing this product
Tags:

 

   This product is mainly used to measure the thickness of non-conductive coating on metal surface, as well as the thickness of non-ferromagnetic coating on ferromagnetic metal (such as iron, nickel, cobalt, etc.), such as paint thickness on automobile surface, coating thickness of metal parts and so on. This product also has built-in magnetic induction and vortex double principle probe, can 

  automatically identify the measured metal substrate, only need to be placed on the measured surface, can automatically calculate the thickness of the coating.

     

  

  Specifications:

  Probe: F probe, N probe

  Magnetic induction: Measuring principle(F), Eddy current effect(N)

  Measuring range: 0-2000um

  Precision: ±(3%+1um)

  Resolution: 0um-99.9um(0.1um) 100um-999um(1um) >1000um(0.01mm)

  Zero calibration: Support

  Statistics: Average, minimum, maximum, number

  Unit: um,mm,mils

  Minimum convex Radian: 5mm

  Minimum concave Radian: 25mm

  Minimum measured area: Diameter 20mm

  Minimum substrate thickness: 0.2mm 0.05mm

  Maximum measuring speed: 2 readings per second

  Power supply: 2*1.5V AAA battery(not included)

  Operating environment: Temperature 0-50°C, 20-90% rh (non-condensed)

  Preservation environment: Temperature:-10-60°C, 20-90% rh (non-condensation)

  Size /weight/material: 113mmX53mmX24mm/80g/ABS

     

  

  Measurement step:

  Step 1. Prepare the parts to be tested. 

  Step 2. Stay away from the metal object at least 2 cm, press the switch key to turn on. 

  Note: it is suggested that the instrument should be zeroed with reference to "zero calibration" before 

  testing. 

  Step 3. The probe is placed vertically and quickly on the surface to be measured until the drop is heard, 

  and the measured value is displayed on the screen, and then the probe is lifted at least 2 cm away from 

  the part to be measured, and the next measurement can be carried out. 

  Note: if the automatic shutdown function is turned on and there is no operation within 3 minutes, the 

  instrument will automatically shut down

     

  

  This machine has two calibration methods:

  1. Basic calibration: the base calibration should be carried out when it is used for the first time, or has 

  not been used for a long time, or when replacing the tested substrate material. There are 7 calibration 

  points in the basic calibration, and the calibration unit is mm.. 

  a. Prepare 6 pieces of standard film, the thickness of which is in0. 04 ~ 0.06,0.09 ~ 0. 11, 0.22 ~ 0.28, 

  0. 45 ~ 0.55,1. 90 ~ 1.05,1.90 ~ 2.00. 

  b. First hold down the up key to hold, then press the on key, LCD full screen kettle display, and then 

  hear a BI, LCD display Display 00mm, the lower right corner of the LCD displays the CAL character,ʺRelease 

  the up buttonʺ indicating that the calibration screen is entered. 

  c. Press the probe lightly on the uncoated aluminum base, at which point the LCD displays 0.00, and 

  then BI-BI calibrates twice. 

  d. Get rid of the probe and show the number of 0.05mm on the LCD. The second number calibration is 

  carried out, and the probe is gently pressed on the aluminum base where the calibration sheet is placed. 

  After adjusting the value displayed on the LCD and the thickness of the calibration sheet by pressing the 

  upper and lower keys, remove the probe and Bi-Bi-Sound, the second calibration point has been calibrated.

     

  

  Zero calibration:

  In order to improve the test accuracy, it is suggested that the instrument should be calibrated to zero. 

  a. Preparation of uncoated substrate to be tested 

  b. Hold down the right hand until you hear the drop, and the "zero calibration (ZERO)" on the screen 

  will begin to flicker. 

  c. The probe is placed vertically and quickly on the surface of the uncoated substrate to be tested. 

  After hearing the dripping sound, the screen will display "0", and the probe can be lifted at least 2 cm 

  away from the substrate, that is, to return to zero once.

  

     

  

 



 


RETURNS POLICY

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

SHIPPING

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

How to choose the correct size:

Step 1 Please measure your foot length carefully.

Step 2 Please choose the correct size according to your foot length and chinese size.

For example, If your foot length is 255 mm , you should choose the size 8.

Step 3 If you\'re not sure of the correct size, you can click chat with us!

WHATSAPP:+8613625959351

Avoir des questions? Demandez à un expert
HW-300S Auto Digital Thickness Gauge Car Paint Thickness Meter Coating Thickness Gauge Measuring Tool Accessories 40%Off
You have successfully subscribed!