{"product_id":"hw-300s-auto-digital-thickness-gauge-car-paint-thickness-meter-coating-thickness-gauge-measuring-tool-accessories-40-off","title":"HW-300S Auto Digital Thickness Gauge Car Paint Thickness Meter Coating Thickness Gauge Measuring Tool Accessories 40%Off","description":"\u003cdiv\u003e\u003cspan\u003e\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   This product is mainly used to measure the thickness of non-conductive coating on metal surface, as well as the thickness of non-ferromagnetic coating on ferromagnetic metal (such as iron, nickel, cobalt, etc.), such as paint thickness on automobile surface, coating thickness of metal parts and so on. This product also has built-in magnetic induction and vortex double principle probe, can \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  automatically identify the measured metal substrate, only need to be placed on the measured surface, can automatically calculate the thickness of the coating.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Specifications:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Probe: F probe, N probe\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Magnetic induction: Measuring principle(F), Eddy current effect(N)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Measuring range: 0-2000um\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Precision: ±(3%+1um)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Resolution: 0um-99.9um(0.1um) 100um-999um(1um) \u0026amp;gt;1000um(0.01mm)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Zero calibration: Support\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Statistics: Average, minimum, maximum, number\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Unit: um,mm,mils\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Minimum convex Radian: 5mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Minimum concave Radian: 25mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Minimum measured area: Diameter 20mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Minimum substrate thickness: 0.2mm 0.05mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Maximum measuring speed: 2 readings per second\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Power supply: 2*1.5V AAA battery(not included)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Operating environment: Temperature 0-50°C, 20-90% rh (non-condensed)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Preservation environment: Temperature:-10-60°C, 20-90% rh (non-condensation)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Size \/weight\/material: 113mmX53mmX24mm\/80g\/ABS\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Measurement step:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Step 1. Prepare the parts to be tested. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Step 2. Stay away from the metal object at least 2 cm, press the switch key to turn on. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Note: it is suggested that the instrument should be zeroed with reference to \"zero calibration\" before \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  testing. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Step 3. The probe is placed vertically and quickly on the surface to be measured until the drop is heard, \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  and the measured value is displayed on the screen, and then the probe is lifted at least 2 cm away from \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  the part to be measured, and the next measurement can be carried out. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Note: if the automatic shutdown function is turned on and there is no operation within 3 minutes, the \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  instrument will automatically shut down\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  This machine has two calibration methods:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  1. Basic calibration: the base calibration should be carried out when it is used for the first time, or has \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  not been used for a long time, or when replacing the tested substrate material. There are 7 calibration \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  points in the basic calibration, and the calibration unit is mm.. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  a. Prepare 6 pieces of standard film, the thickness of which is in0. 04 ~ 0.06,0.09 ~ 0. 11, 0.22 ~ 0.28, \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  0. 45 ~ 0.55,1. 90 ~ 1.05,1.90 ~ 2.00. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  b. First hold down the up key to hold, then press the on key, LCD full screen kettle display, and then \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  hear a BI, LCD display Display 00mm, the lower right corner of the LCD displays the CAL character,ʺRelease \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  the up buttonʺ indicating that the calibration screen is entered. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  c. Press the probe lightly on the uncoated aluminum base, at which point the LCD displays 0.00, and \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  then BI-BI calibrates twice. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  d. Get rid of the probe and show the number of 0.05mm on the LCD. The second number calibration is \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  carried out, and the probe is gently pressed on the aluminum base where the calibration sheet is placed. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  After adjusting the value displayed on the LCD and the thickness of the calibration sheet by pressing the \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  upper and lower keys, remove the probe and Bi-Bi-Sound, the second calibration point has been calibrated.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Zero calibration:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  In order to improve the test accuracy, it is suggested that the instrument should be calibrated to zero. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  a. Preparation of uncoated substrate to be tested \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  b. Hold down the right hand until you hear the drop, and the \"zero calibration (ZERO)\" on the screen \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  will begin to flicker. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  c. The probe is placed vertically and quickly on the surface of the uncoated substrate to be tested. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  After hearing the dripping sound, the screen will display \"0\", and the probe can be lifted at least 2 cm \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  away from the substrate, that is, to return to zero once.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003c\/span\u003e\u003c\/div\u003e","brand":"mickcara","offers":[{"title":"Orange","offer_id":40867857301641,"sku":"a01248-1","price":38.0,"currency_code":"USD","in_stock":true},{"title":"Black","offer_id":40867857334409,"sku":"a01248-2","price":38.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0365\/2131\/2393\/products\/57da425f5d66729103e78bedd4f3ee8f.jpg?v=1665455221","url":"https:\/\/mickcara.com\/fr\/products\/hw-300s-auto-digital-thickness-gauge-car-paint-thickness-meter-coating-thickness-gauge-measuring-tool-accessories-40-off","provider":"mickcara","version":"1.0","type":"link"}