{"product_id":"medical-hospital-sick-bed-alternating-pressure-air-mattress-with-pump-prevent-bedsores-and-decubitus-pneumatic-massage-cushion","title":"Medical Hospital Sick Bed Alternating Pressure Air Mattress with Pump Prevent Bedsores and Decubitus Pneumatic Massage Cushion","description":"\u003cdiv\u003e\u003cspan\u003e\u003cbr style=\"white-space: normal;\"\u003eFirst, the product name:\u003cbr style=\"white-space: normal;\"\u003eAnti-decubitus mattress\u003cbr style=\"white-space: normal;\"\u003e\u003cbr style=\"white-space: normal;\"\u003eSecond, the scope of application:\u003cbr style=\"white-space: normal;\"\u003eThis product is suitable for bedridden patients, to prevent patients from acne due to long-term bed.\u003cbr style=\"white-space: normal;\"\u003e\u003cbr style=\"white-space: normal;\"\u003eThird, the product structure consists of:\u003cbr style=\"white-space: normal;\"\u003eThis product is composed of inflatable cushion and air pump. The inflatable cushion is made of high frequency heat-sealable PVC cloth. It has a spherical air chamber. The air pump is connected to the inflatable cushion through joints, air pipes, air inlets, etc. Inflate the air chamber.\u003cbr style=\"white-space: normal;\"\u003e\u003cbr style=\"white-space: normal;\"\u003eV. Working principle:\u003cbr style=\"white-space: normal;\"\u003eThrough the inflator pump, the odd and even air chambers of the inflatable cushion are alternately filled and deflated, so that the patient's body bed part is in intermittent contact with the cushion surface to achieve an anti-acne effect. When the inflation pressure reaches 3 kPa, the cushioned micro-jet holes are evenly distributed. Emissions of gases outside the body improve air circulation under the body of the patient and enhance anti-acne effects.\u003cbr style=\"white-space: normal;\"\u003e\u003cbr style=\"white-space: normal;\"\u003eSixth, the main technical indicators:\u003cbr style=\"white-space: normal;\"\u003e1, when filling and deflation: single pump air pump inflation 5min ± 5%, deflation 5min ± 5%, dual pump air pump 9min ± 5%, deflation 9min ± 5%;\u003cbr style=\"white-space: normal;\"\u003e2. Inflatable air pressure: 12kPa ± 0.5kPa (can be adjusted between 0 and maximum air pressure);\u003cbr style=\"white-space: normal;\"\u003e3, the most weight bearing: 120kg;\u003cbr style=\"white-space: normal;\"\u003e4, working noise: \u0026lt;60dB\u003cbr style=\"white-space: normal;\"\u003e5, continuous working time: \u0026gt;24h\u003cbr style=\"white-space: normal;\"\u003e6. Inflatable pump power consumption: \u0026lt;20VA\u003cbr style=\"white-space: normal;\"\u003e\u003cbr style=\"white-space: normal;\"\u003eVII. Working conditions:\u003cbr style=\"white-space: normal;\"\u003e1, bad environment temperature: 5-40 °C;\u003cbr style=\"white-space: normal;\"\u003e2. Relative humidity: \u0026lt;85%\u003cbr style=\"white-space: normal;\"\u003e3, power conditions: 220V ± 22V, 50hz\u003cbr style=\"white-space: normal;\"\u003e\u003cbr style=\"white-space: normal;\"\u003eEight, use method:\u003cbr style=\"white-space: normal;\"\u003e1. Place the air mattress on the sickbed or single bed (the surface of the bed surface cannot be pointed or hard to prevent the air cushion from being damaged) so that the air intake hole is located on the patient's foot;\u003cbr style=\"white-space: normal;\"\u003e2. Take the air pump out of the foam box, according to the situation, it can be placed on the desktop or under the bed with a solid position more than 20cm above the ground, and the use environment should be clean and dry;\u003cbr style=\"white-space: normal;\"\u003e3. Turn on the air pump power, turn on the power switch, and turn the pressure adjusting knob clockwise to the maximum state. The air outlet of the air pump has gas discharge, which is suitable for single pump air pump;\u003cbr style=\"white-space: normal;\"\u003e4. Connect one end of the airway tube to the air nozzle on the mattress, and connect the other end to the air outlet on the right side of the air pump. The connection should be firmly in place and no air leakage can occur.\u003cbr style=\"white-space: normal;\"\u003e5. The air mattress enters into the inflation work state. After inflating for 15-20 minutes, the pressure in the air bed can reach the normal state of use. If necessary, a bed sheet can be laid on the air mattress and the patient can be moved to the air cushion according to the needs of the patient. Adjust the air pump pressure adjustment knob to change the softness of the air heat;\u003cbr style=\"white-space: normal;\"\u003e6. Unfasten the snaps on both sides when you are in urine and excretion, and open the small air cushion at the hole. Then you can use it conveniently. Then return to the original position to restore the fluctuating state.\u003cbr style=\"white-space: normal;\"\u003e7, according to the needs of the patient can be used for 24 hours continuous inflation, or use as directed\u003cbr style=\"white-space: normal;\"\u003e\u003cbr style=\"white-space: normal;\"\u003eNine, contraindications:\u003cbr style=\"white-space: normal;\"\u003eAnti-decubitus gas bed has a thermal fluctuation function, the fracture surgery can not use this product.\u003cbr style=\"white-space: normal;\"\u003e\u003cbr style=\"white-space: normal;\"\u003eTenth, safety precautions:\u003cbr style=\"white-space: normal;\"\u003e1. If abnormal operation of the air pump (such as loud noise, odor, etc.) is found during use, cut off the power immediately and stop using it.\u003cbr style=\"white-space: normal;\"\u003e2. Patients with a resting weight exceeding 120KG cannot use this mattress.\u003cbr style=\"white-space: normal;\"\u003e3. The mattress cannot be used by patients who do not heal the surgical incision.\u003cbr style=\"white-space: normal;\"\u003e4, in the use of the process should avoid contact with sharp hard objects, so as not to scratch the mattress.\u003cbr style=\"white-space: normal;\"\u003e5. Care should be taken to keep the mattress clean, and often use neutral detergents to avoid contact with contaminants.\u003cbr style=\"white-space: normal;\"\u003e6. In case of failure during use, the air mattress should be repaired by a trained professional to notify the manufacturer of maintenance.\u003cbr style=\"white-space: normal;\"\u003e7. When not in use, the gas in the mat should be drained, folded into the original crates, stored in a dry, well-ventilated, ambient temperature -20°- + 55°C, relative humidity not exceeding 90%, non-corrosive substances Indoors, and into strong sunlight.\u003cbr style=\"white-space: normal;\"\u003e8. This product should be used under the guidance of a doctor.\u003cbr style=\"white-space: normal;\"\u003e\u003cbr style=\"white-space: normal;\"\u003eEleven, quality assurance instructions:\u003cbr style=\"white-space: normal;\"\u003e1, Within six months of purchasing this product,\u003cbr style=\"white-space: normal;\"\u003e2. For products that last more than half a year, the company shall be responsible for free maintenance. Only freight and accessories fees will be charged for maintenance.\u003cbr style=\"white-space: normal;\"\u003e3. Damage caused by improper use or due to improper storage is not within the scope of service.\u003cbr style=\"white-space: normal;\"\u003e4. If you find the quality problem of this product, please contact us as soon as possible so as to serve you in time.\u003cbr style=\"white-space: normal;\"\u003eTwelve, storage method:\u003cbr style=\"white-space: normal;\"\u003e\u003cbr style=\"white-space: normal;\"\u003eWhen using, keep it clear, store it in a dry and ventilated place, pay attention to moisture.First, the product name:\u003cbr\u003eAnti-decubitus mattress\u003cbr\u003e\u003cbr\u003eSecond, the scope of application:\u003cbr\u003eThis product is suitable for bedridden patients, to prevent patients from acne due to long-term bed.\u003cbr\u003e\u003cbr\u003eThird, the product structure consists of:\u003cbr\u003eThis product is composed of inflatable cushion and air pump. The inflatable cushion is made of high frequency heat-sealable PVC cloth. It has a spherical air chamber. The air pump is connected to the inflatable cushion through joints, air pipes, air inlets, etc. Inflate the air chamber.\u003cbr\u003e\u003cbr\u003eV. Working principle:\u003cbr\u003eThrough the inflator pump, the odd and even air chambers of the inflatable cushion are alternately filled and deflated, so that the patient's body bed part is in intermittent contact with the cushion surface to achieve an anti-acne effect. When the inflation pressure reaches 3 kPa, the cushioned micro-jet holes are evenly distributed. Emissions of gases outside the body improve air circulation under the body of the patient and enhance anti-acne effects.\u003cbr\u003e\u003cbr\u003eSixth, the main technical indicators:\u003cbr\u003e1, when filling and deflation: single pump air pump inflation 5min ± 5%, deflation 5min ± 5%, dual pump air pump 9min ± 5%, deflation 9min ± 5%;\u003cbr\u003e2. Inflatable air pressure: 12kPa ± 0.5kPa (can be adjusted between 0 and maximum air pressure);\u003cbr\u003e3, the most weight bearing: 120kg;\u003cbr\u003e4, working noise: \u0026lt;60dB\u003cbr\u003e5, continuous working time: \u0026gt;24h\u003cbr\u003e6. Inflatable pump power consumption: \u0026lt;20VA\u003cbr\u003e\u003cbr\u003eVII. Working conditions:\u003cbr\u003e1, bad environment temperature: 5-40 °C;\u003cbr\u003e2. Relative humidity: \u0026lt;85%\u003cbr\u003e3, power conditions: 220V ± 22V, 50hz\u003cbr\u003e\u003cbr\u003eEight, use method:\u003cbr\u003e1. Place the air mattress on the sickbed or single bed (the surface of the bed surface cannot be pointed or hard to prevent the air cushion from being damaged) so that the air intake hole is located on the patient's foot;\u003cbr\u003e2. Take the air pump out of the foam box, according to the situation, it can be placed on the desktop or under the bed with a solid position more than 20cm above the ground, and the use environment should be clean and dry;\u003cbr\u003e3. Turn on the air pump power, turn on the power switch, and turn the pressure adjusting knob clockwise to the maximum state. The air outlet of the air pump has gas discharge, which is suitable for single pump air pump;\u003cbr\u003e4. Connect one end of the airway tube to the air nozzle on the mattress, and connect the other end to the air outlet on the right side of the air pump. The connection should be firmly in place and no air leakage can occur.\u003cbr\u003e5. The air mattress enters into the inflation work state. After inflating for 15-20 minutes, the pressure in the air bed can reach the normal state of use. If necessary, a bed sheet can be laid on the air mattress and the patient can be moved to the air cushion according to the needs of the patient. Adjust the air pump pressure adjustment knob to change the softness of the air heat;\u003cbr\u003e6. Unfasten the snaps on both sides when you are in urine and excretion, and open the small air cushion at the hole. Then you can use it conveniently. Then return to the original position to restore the fluctuating state.\u003cbr\u003e7, according to the needs of the patient can be used for 24 hours continuous inflation, or use as directed\u003cbr\u003e\u003cbr\u003eNine, contraindications:\u003cbr\u003eAnti-decubitus gas bed has a thermal fluctuation function, the fracture surgery can not use this product.\u003cbr\u003e\u003cbr\u003eTenth, safety precautions:\u003cbr\u003e1. If abnormal operation of the air pump (such as loud noise, odor, etc.) is found during use, cut off the power immediately and stop using it.\u003cbr\u003e2. Patients with a resting weight exceeding 120KG cannot use this mattress.\u003cbr\u003e3. The mattress cannot be used by patients who do not heal the surgical incision.\u003cbr\u003e4, in the use of the process should avoid contact with sharp hard objects, so as not to scratch the mattress.\u003cbr\u003e5. Care should be taken to keep the mattress clean, and often use neutral detergents to avoid contact with contaminants.\u003cbr\u003e6. In case of failure during use, the air mattress should be repaired by a trained professional to notify the manufacturer of maintenance.\u003cbr\u003e7. When not in use, the gas in the mat should be drained, folded into the original crates, stored in a dry, well-ventilated, ambient temperature -20°- + 55°C, relative humidity not exceeding 90%, non-corrosive substances Indoors, and into strong sunlight.\u003cbr\u003e8. This product should be used under the guidance of a doctor.\u003cbr\u003e\u003cbr\u003eEleven, quality assurance instructions:\u003cbr\u003e1, Within six months of purchasing this product,\u003cbr\u003e2. For products that last more than half a year, the company shall be responsible for free maintenance. Only freight and accessories fees will be charged for maintenance.\u003cbr\u003e3. Damage caused by improper use or due to improper storage is not within the scope of service.\u003cbr\u003e4. If you find the quality problem of this product, please contact us as soon as possible so as to serve you in time.\u003cbr\u003eTwelve, storage method:\u003cbr\u003e\u003cbr\u003eWhen using, keep it clear, store it in a dry and ventilated place, pay attention to moisture.\u003c\/span\u003e\u003c\/div\u003e","brand":"mickcara","offers":[{"title":"A","offer_id":40475353841801,"sku":"002245-1","price":188.0,"currency_code":"USD","in_stock":true},{"title":"B","offer_id":40475353874569,"sku":"002245-2","price":188.0,"currency_code":"USD","in_stock":true},{"title":"C","offer_id":40475353907337,"sku":"002245-3","price":188.0,"currency_code":"USD","in_stock":true},{"title":"D","offer_id":40475353940105,"sku":"002245-4","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0365\/2131\/2393\/products\/d7a469f30cde46bbb40a0771a6a839a3.jpg?v=1656334794","url":"https:\/\/mickcara.com\/fr\/products\/medical-hospital-sick-bed-alternating-pressure-air-mattress-with-pump-prevent-bedsores-and-decubitus-pneumatic-massage-cushion","provider":"mickcara","version":"1.0","type":"link"}