 I.Introduction:

   Analysis for 3P4W, 3P3W, 1P2W, 1P3W

  True RMS Value(V 123 and L 123 )

  Active Power(W, KW, MW, GW)

  Apparent and Reactive Power (KVA, KVAR)

  Power Factor (PF), Phase Angle (Φ)

  Energy (WH, KWH, KVARH, PFH)

  Current Measurement from 0.1mA to 3000A, Capable of Analyzing IT Standby Power Consumption to the Maximum Demand of a Factory

  Display of 35 Parameters in One Screen(3P4W)

  rogrammable CT (1 to 600) and PT (1 to 3000) Ratios

  Display of Overlapped Voltage and Current Waveform

  2.4M Memory with Programmable Interval (1 to 6000 seconds, 17000 Records for 3P4W System)

  Output of Waveform, Power Parameters and Harmonics at Command

  Large Dot Matrix LCD Display with Backlight

  Average Demand (AD in W, KW, MW)

  aximum Demand (MD in W, KW, MW) with Programmable Period

  Harmonic Analysis to the 99th Order

  Display of 50 Harmonics in One Screen with Waveform

  Display of Waveform with Peak Values (1024 Samples/Period)

  Analysis of Total Harmonic Distortion (%THD-F)

  Graphic Phasor Diagram with 3 Phase System Parameters

  Capture 28 Transient Events (Time+Cycles) with Programmable Threshold(%)

  3 Phase Voltage Unbalance Ratio (VUR)

  3 Phase Voltage Unbalance Factor (d0%, d2%)

  Calculated Unbalance Current through Neutral Line (In)

  Optical isolated USB Interface

  Built-in Timer and Calendar for Data Logging

  onductor Size: -Model 6801 30mm(approx) -Model 6802 5

         55mm(approx),64*24mm(bus bar) -Model 3007 170mm(approx) 

   

II.Specification

 

                                    * Please refer to users manual for more detailed and up-to-date description of specification  

                  

                                    AC Watt (50 or 60 Hz, PF 0.5 to 1, CT=1)

                  

                                             Range         

                           Resolution         

                           Accuracy of Readings         

                      6800+6801

        6800+6802

                           6800+3007         

                                         5.0 – 999.9W         

                           0.1W         

                           ±1% ± 8dgts         

                           ±1% ± 8dgts         

                           ±1% of VA Range ±8dgts         

                                         1.000 – 9.999 KW         

                           0.001 KW         

                           ±1% ± 8 dgts         

                           ±1% ± 8 dgts         

                           ±1% of VA Range ±8dgts         

                                         10.00 – 99.99 KW         

                           0.01 KW         

                           ±1% ± 8 dgts         

                           ±1% ± 8 dgts         

                           ±1% of VA Range ±8dgts         

                                         100.0 – 999.9 KW         

                           0.1 KW         

                           ±1% ± 8dgts         

                           ±1% ± 8dgts         

                           ±1% of VA Range ±8dgts         

                                         1000 – 9999 KW         

                           1 KW         

                           ±1% ± 8dgts         

                           ±1% ± 8dgts         

                           ±1% of VA Range ±8dgts         

                                         0.000 – 9.999MW         

        0.001MW

                           –         

                           ±1% ± 8 dgts         

                           ±1% of VA Range ±8dgts         

                  

                                    AC Current( 50 or 60Hz, Auto Range,True RMS,Crest Factor<4,CT=1)

                  

                          

                           Range         

                           Resolution         

                           Accuracy of Readings         

                      6830+6801

(Overload Protection AC200A)

                           0.050 – 9.999A         

                           0.001A         

                           ±0.5% ± 5dgts         

                                         10.00 – 60.00A         

                           0.01A         

                           ±0.5% ± 5dgts         

                                         60.00 – 99.99A         

                           0.01A         

                           ±1.0% ± 5dgts         

                      6830+6802

(Overload Protection AC2000A)

                           0.04 – 10.00A         

                           0.01A         

                           –         

                                         0.4A – 100.0A         

                           0.1A         

                           ±0.5% ± 5dgts         

                                         4.0 – 1000.0A         

                           1A         

                           ±0.5% ± 5dgts         

                                         6830+3007         

(Overload Protection AC3500A)

                           4 – 300A         

                           0.1A         

                           ±1% of Range ±5dgts         

                                         300.0 – 999.9A         

                           0.1A         

                           ±1% of Range ±5dgts         

                                         1000 – 3000A         

                           1A         

                           ±1% of Range ±5dgts         

                  

                                    AC Voltage (50 or 60 Hz, Auto Range, True RMS, Crest Factor<4)

                  

                                             Range         

                           Resolution         

                           Accuracy of Readings         

                           Range         

                           Resolution         

                           Accuracy of Readings         

                      4.0V – 500.0 (Phase to Neutral)

        0.1V

        ± 0.5% ± 5dgts

        4.0V –600.0V (Phase to phase)

        0.1V

        ± 0.5% ± 5dgts

                  

                                    Harmonics of AC Voltage in % and in Magnitude (1 to 99th order, minimum voltage at the 50 or 60 Hz>AC 80V)

                  

                                             Range         

                           In Percentage         

                           In Magnitude         

                                         Resolution         

                           Accuracy of readings         

                           Resolution         

                           Accuracy of readings         

                                         1 – 20 th         

        0.1%

                           ±2%         

        0.1 V

                           ±2% ±0.5V         

                                         21 – 49 th         

                           4% of reading ±2.0%         

                           4% of reading ±0.5A         

                                         50 – 99 th         

                           6% of reading ±2.0%         

                           6% of reading ±0.5A         

                  

                                    Harmonics of AC Current in % and in Magnitude

Model 6830+6801(100A)(1 to 99th order, minimum current at 50 or 60 Hz is greater than 10% of the range)

                  

                                             Range         

                           In Percentage         

                           In magnitude         

                                         Resolution         

                           Accuracy of reading         

                           Resolution         

                           Accuracy of reading         

                                         1 – 10 th         

        0.1%

                           ±0.2 of reading ±1%         

                           0.1mA / 0.1A         

                           ±0.2% of reading ±7dgts         

                                         11 – 20 th         

                           ±2% of reading ±1%         

                           ±2% of reading ±7dgts         

                                         2 1 – 50 th (A range)         

                           ±5% of reading ±1%         

                           ±5% of reading ±7dgts         

                                         2 1 – 50 th (mA range)         

                           ±10% of reading ±1%         

                           ±10% of reading ±7dgts         

                                         5 1 – 99 th         

                           ±35% of reading ±1%         

                           ±35% of reading ±7dgts         

                  

                                    Model 6830+6802(1000A);6830+3007(3000A)(1 to 99th order, minimum current at the 50 or 60 Hz>20A)

                  

                                             Range         

                           In Percentage         

                           In Magnitude         

                                         Resolution         

                           Accuracy of reading         

                           Resolution         

                           Accuracy of reading         

                                         1 – 20 th         

                           0.1%         

                           ±2%         

        0.1A(6802) / 0.3A(3007)

                           ±2% of reading ±0.4A/0.6A         

                                         21 – 49 th         

                           4% of reading ±2.0%         

                           ±4% of reading ± 0.4A/0.6A         

                                         50 – 99 th         

                           6% of reading ±2.0%         

                           ±6% of reading ± 0.4A/0.6A         

                  

                                    Total Harmonic Distortion

                  

                                             Range         

                           Resolution         

                           Accuracy(6801)         

                           Accuracy(6802)         

                           Accuracy(3007)         

                                         0.0 – 20%         

                           0.1%         

                           ±1%         

                           ±2%         

                           ±2%         

                                         20 – 100%         

                           0.1%         

                           ±3% of reading ±5%         

                           ±6% of reading ±1%         

                           ±6% of Range ±1%         

                                         100 – 999.9%         

                           0.1%         

                           ±10% of reading ±10%         

                           ±10% of reading ±1%         

        ±10% of Range ±1%

                  

                                    Peak Value of Ac Voltage or AC Current ,VT=1

                  

                                             Range         

                           Sampling Time         

                           Accuracy of reading         

                                         50Hz         

                           39 μS         

                           ±5% ±30digits         

                                         60Hz         

                           33 μS         

                           ±5% ±30 digits         

                  

                                    Crest Factor (C.F.) of ACV or ACA ,VT=1

                  

                                             Range         

                           Resolution         

                           Accuracy of reading         

                                         1.00 – 99.99         

                           0.01         

                           ±5% ±30digits         

                  

                                    Frequency in AUTO mode

                  

                                             Range         

                           Resolution         

                           Accuracy of reading         

                                         45 – 65Hz         

                           0.1Hz         

                           0.1Hz         

                  

                                    Power Factor (PF)

                  

                                             Range         

                           Resolution         

                           Accuracy of reading         

                                         0.00 – 1.00         

                           0.01         

                           ± 0.04         

                  

                                                       Range         

                           Resolution         

                           Accuracy of reading         

                                         -180 to 180         

                           0.1         

                           ± 1         

                  

                                    

                  

                          Conductor Size (6801)

        30mm (approx)

                      Conductor Size (6802)

        55mm(approx.), 64 X 24mm(Bus Bar)

                      Battery Type

        1.5V SUM-3 x 8

                      Display

        Dot Matrix LCD with backlight

                      Power Consumption

        140mA (approx.)

                      External DC Input

        DC 12V adaptor (for safety purpose, the adaptor must be certified with 600Visolation protection)

                      LCD update rate

        1 times / sec

                      No. Of Samples/Period

        1024

                      Operating Humidity

        < 85% relative

                      Operating Temperature

        -10°C to 50°C

                      Storage Humidity

        < 75% relative

                      Storage Temperature

        - 20°C to 60°C

                      Weight(6830)

        1160g

                      Weight(6801)

        200g

                      Weight(6802)

        600g

                      Dimension(6830)

        257 (L) x 155 (W) x 57 (H) mm ,10.1"(L) x 6.1" (W) x 2.3" (H)

                      Dimension(6801)

        210 (L) x 62 (W) x 36 (H) mm ,8.3 " (L) x 2.5" (W) x 1.4" (H)

                      Dimension(6802)

        244 (L) x 97 (W) x 46 (H) mm ,9.6 " (L) x 3.8" (W) x 1.8" (H)

                      Accessories

        Test leads x 4,alligator clips x 4,Carrying bag x 1,Users manual x 1,Batteries 1.5V x 8

                  


RETURNS POLICY

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

SHIPPING

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

How to choose the correct size:

Step 1 Please measure your foot length carefully.

Step 2 Please choose the correct size according to your foot length and chinese size.

For example, If your foot length is 255 mm , you should choose the size 8.

Step 3 If you\'re not sure of the correct size, you can click chat with us!

WHATSAPP:+8613625959351

Avoir des questions? Demandez à un expert
Power And Harmonics Analyzer PROVA-6830A With 3000A Current Clamp
You have successfully subscribed!