{"product_id":"tds-100f-ultrasonic-liquid-flow-meter-s2-m2-l2-dn15-6000mm-separate-fixed-wall-mount-type-flowmeter-with-aluminum-cover","title":"TDS-100F Ultrasonic Liquid Flow Meter S2 M2 L2 ( DN15-6000mm ) Separate Fixed Wall-mount Type Flowmeter with Aluminum Cover","description":"\u003cdiv\u003e\u003cspan\u003e\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTransducer Selection:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e          Transducer\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    Standard S2 type\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    Standard M2 type\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    Standard L2 type\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e          Suitable pipe diameter\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    DN15-DN100mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    DN50-DN700mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    DN300-DN6000mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e          Fluid temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    0°c-160°c\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    0°c-160°c\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    0°c-160°c\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e          Outer size\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    45×30×30mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    60×45×45\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    80×70×55\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e          Quality\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    75g\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    250g\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    528g\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSpecification:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Linearity\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Better than ±1%.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Accuracy \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   ±1% of reading at rates \u0026amp;gt;0.6 ft\/s (0.2m\/s). Assume a fully developed flow profile.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Repeatability\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   ±0.2%.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Velocity\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   ±0.03 ~ ±105 ft\/s \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e(±0.01 ~ ±30 m\/s), bi-directional\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Measurement Period\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   0.5s\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Display\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   LCD with backlight.  2x20 letters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Keypad\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   4x4-key membrane keypad with \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003etactile feedback\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Units\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   English (U.S.) or metric.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Outputs\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Analogue output: 4-20mA or 0-20mA current output. Impedance 0~1kW. Accuracy 0.1%. .\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Isolated OCT output: for frequency output (0~9,999Hz), alarm driver, or totaliser pulse output, ON\/OFF control, etc.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eRelay output 1A@125VAC or 2A@30VDC. For ON\/OFF control, alarm driver, totaliser output, etc.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Internal Alarm (Buzzer): user programmable.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eExternal Alarm Driver: alarm signal can be transmitted to Relay or OCT output terminals to drive an external alarm. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       RS-232 serial port. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Input\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Five channel 4-20mA current inputs for signals such as temperature, pressure, liquid level, and etc.. Accuracy 0.1%.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTwo of the five input channels are wired to terminal blocks. The remaining three channels are optional.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Enclosure\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Die-cast aluminum enclosure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Protection Class:  IP65 (NEMA 4X).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Size: 9.88x7.56x3.15 (251x192x80mm3) for standard version\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Clamp-on\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   S2-type: for pipe size  (DN15~DN100mm)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       M2-type: for pipe size (DN50~DN700mm)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       L2-type: for pipe size (DN300~DN6,000mm)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Liquid Types \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Virtually all commonly used clean liquids.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Liquids with small quantity of tiny particles may also be applicable. Particle size should be less than 75um, particle concentration less than 10,000ppm. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Liquids should contain no or very minor air bubbles.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Examples are chilled\/hot water, sea water, waste water, chemical liquids, oil, crude oil, alcohol, beer, etc.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Liquid Temp\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   (0C - 160C) for clamp-on transducer. Higher temperatures can be accommodated. Consult us for assistance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       (0C - 160C) for wetted transducer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Pipe Size \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   1 ~ 240 (DN15mm ~ DN6,000mm).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Pipe Material\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   All metals, most plastics, fiber glass, etc.  Allow pipe liner.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Shielded transducer cable. Standard length 15 (5m). Can be extended to 1640 (500m).  Contact us for longer cable requirement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Power\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   AC: 240V DC: 8VDC~36VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Power consumption: \u0026amp;lt; 2W\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Weight\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Standard main unit: 6.6lb (3kg) \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eStandard Packing:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTDS-100F Ultrasonic Flowmeter\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eClamp Fixture\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eStandard M2 Transducer\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e2 x 5m Signal Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003c\/span\u003e\u003c\/div\u003e","brand":"mickcara","offers":[{"title":"host with S2","offer_id":41380374872201,"sku":"02848-1","price":666.0,"currency_code":"USD","in_stock":true},{"title":"host with M2","offer_id":41380374904969,"sku":"02848-2","price":666.0,"currency_code":"USD","in_stock":true},{"title":"host with L2","offer_id":41380374937737,"sku":"02848-3","price":666.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0365\/2131\/2393\/files\/472ab2da04dd27cacf5bded818913ce1.jpg?v=1694748066","url":"https:\/\/mickcara.com\/fr\/products\/tds-100f-ultrasonic-liquid-flow-meter-s2-m2-l2-dn15-6000mm-separate-fixed-wall-mount-type-flowmeter-with-aluminum-cover","provider":"mickcara","version":"1.0","type":"link"}