UA6013L Auto Range Digital LCD Capacitor Capacitance Test Meter Multimeter Measurement Tester Meter
Features:
6013L type digital capacitance meter is pocket, convenient operation, accurate numerical reading, low-consumption, driven by battery, and showing numbers in a big LCD.
Being accurate in measuring, it covers 9 measuring sections, a wide rang from 0.1pF to 20,00μF.
It can be used in testing error testing, numerical analysis, selecting capacitance, measuring unknown capacitance, matching capacitance, and measuring the capacitance of cable, switch and printing electrocircuit.
Wide measuring range, covering 9 measuring sections from 0.1pF to 20,00μF that includes nominal value of any capacitance.
Descriptions:
Biggest display value: 1999(3 1/2).
Reading: 2-3 readings/sec.
Zeroing: There is a zeroing knob on the front, easy for operation.
Data hold: Put the “HOLD” switch to "ON" and the DH sign will appear on the display.
Temperature for accurate measuring: 25±5°C
Temperature range: working temperature: 0 to 40°C
Storage temperature: -10 to 50°C
Relative humidity: <80%
Power supply: 9V laminated battery(Not included)
Specifications:
Accuracy: ±(%reading±dig)
Quality guarantee: one year
Environment temperature: 25°±5°
Relative humidity:<80%
Rang Accuracy Definition Testing frequency
200pF ±0.5% ±20digit 0.1pF 800Hz
2nF ±0.5%±20digit 1pF 800Hz
20nF ±0.5%±20digit 10pF 800Hz
200nF ±0.5%±20digit 0.1μF 800Hz
2μF ±0.5%±20digit 1nF 800Hz
20μF ±0.5%±20digit 10nF 80Hz
200μF ±0.5%±20digit 0.1μF 8Hz
2000μF ±2.0%±20digit 1μF 8Hz
Color:Grey+Red
Dimension:148 x 75 x 33 mm
Operation:
Firstly, check a 9V battery whether electric voltage is short that will show signal on the left-upper of the LCD. Secondly, pay attention to the polarity or the capacitance to be tested. Thirdly, recharge the capacitance before measuring.
1. Select proper measuring section according to the capacitance to be tested.
2. Check and use the zeroing knob on the front of the meter to adjust the value to zero before measuring.
3. Insert the black sensor into the jack with “-”signal and the red sensor into the jack with “+”.
4. Connect the capacitance to be tested with the two sensors. Pay attention to the polarity of the capacitance ! Read capacitance numerical value displayed.
Notes
a. If you don't know the approximate value of a capacitance, you should select measuring section of 200nF and then make relevant adjusting according to practical situation.
b. If the capacitance is in short circuit, the meter shows "beyond measuring range". If the capacitance is in electric leakage, the meter shows "beyond measuring range" or "much bigger than the normal value". If the capacitance is open-circuit, the meter shows "Zero" or "several pF ".
c. In testing small capacitance, directly insert the capacitance into the jack instead of using the sensors for better accuracy.
Maintenance
The meter is of highly accurate electronic apparatus. Don't change internal circuit rashly for no damage to the meter.
1. Don't exert electric voltage upon the jack parts of the meter for no damage to the meter.
2. Don't test the sensors in short circuit , or the battery will be consumed out quickly.
3. Don't use a meter whose back cover doesn't cover the meter well.
4. Always replace battery and fuse after taking sensors out of a meter that is switched off. First, screw bolts in the back cover out. Second, take off the back cover. Third, replace battery and fuse according to specification provisioned in the operation manual. Suitable fuse for this meter is 200mA/250V, which external dimension is φ5×20㎜.
5. Please take out the battery when not using for a long time.
Package included:
1 x Capacitance Tester
2 x Probes
Logistics information
Our products are located in Hong Kong, China, and the logistics speed depends on your specific location. According to our experience, it usually takes about 15-20 days of transportation time
CONTACT US
RETURNS POLICY
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.
Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.
Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.
SHIPPING
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.
Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.
Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

How to choose the correct size:
Step 1 Please measure your foot length carefully.

Step 2 Please choose the correct size according to your foot length and chinese size.
For example, If your foot length is 255 mm , you should choose the size 8.