Feature
With bandwidth of 200MHz and real-time sampling rate of 1GSa/s, more than 1000 waveforms and other information can be stored
Large and clear screen (7.0-inch LCD, 800x480 resolution), humanized operation interface,Powerful trigger function
Integrated USB Host, support U disk storage, USB interface system upgrade
The 7-inch 64K TFT real color LCD display is clear and lifelike
Ultra-thin design, compact size, easy to carry
Specification:
Brand
Hantek
Model
DSO5202P
Voltage
110-240V
Plug
EU plug
Acquisition
Sample Rate
Real-Time Sample: 1GS/s
Acquisition Modes
Normal
Normal data only
Peak Detect
High-frequency and randon glith capture
Average
Wavefom Average, selectable 4,8,16,32,64,128
Inputs
Inputs Coupling
AC, DC, GND
Inputs Impendance
1M????2% I 20pF??3pF
Probe Attenuation
1X, 10X
Supported Probe Attenuation Factor
1X, 10X, 100X, 1000X
Maximum Input Voltage
CAT I and CAT II: 300VRMS (10x), Installation Category;
CAT III: 150VRMS (1x);
Installation
Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz*
and above. For non-sinusoidal waveforms, peak value must be less than
450V. Excursion above 300V should be of less than 100ms duration. RMS
signal level including all DC components removed through AC coupling
must be limited to 300V. If these values are exceeded, damage to the
oscilloscope may occur.
Horizontal System
Sample Rate Range
500MS/s--1GS/s
Waveform Interpolation
(sin x)/x
Record Length
40K
SEC/DIV Range
2ns/div to 40s/div
Sample Rate and
Delay Time Accuracy
??50ppm(at over any ??1ms time interval)
Position Range
2ns/div to 10ns/div; (-4div x s/div) to 20ms;
Delta Time Measurement Accuracy
(Full Bandwidth)
Single-shot, Normal mode:?? (1 sample interval +100ppm x reading + 0.6ns);
>16 averages:?? (1 sample interval + 100ppm x reading + 0.4ns);
Sample interval = (s/div) /200
Vertical System
Vertical Resolution
8-bit resolution, all channel sampled simultaneously
Position Range
2mV/div to 10V/div
Bandwidth
200MHz
Rise Time at BNC( typical)
1.8ns
Analog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled
2mV/div to 20mV/div, ??400mV; 50mV/div to 200mV/div, ??2V
500mV/div to 2V/div, ??40V; 5V/div, ??50V
Math
+, -, x, /, FFT
FFT
Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman;
1024 sample point
Bandwidth Limit
20MHz
Low Frequency Response (-3db)
??10Hz at BNC
DC Gain Accuracy
??3% for Normal or Average acquisition mode, 5V/div to 10mV/div;
??4% for Normal or Average acquisition mode, 5mV/div to 2mV/div
DC Measurement Accuracy,
Average Acquisition Mode
When vertical displacement is zero, and N ??16:?? (3% x reading + 0.1div + 1mV) only 10mV/div or greater is selected;
When
vertical displacement is not zero, and N??16: ?? (3% x (reading +
vertical position) + 1% of vertical position + 0.2div); Add 2mV for
settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div
to 5V/div
Volts Measurement Repeatability,
Average Acquisition Mode
Delta volts between any two averages of ??16 waveforms acquired under same setup and ambient conditions
Trigger System
Trigger Types
Edge, Video, Pulse, Slope, Over time, Alternative
Trigger Source
CH1, CH2, EXT, EXT/5, AC Line
Trigger Modes
Auto, Normal, Single
Coupling Type
DC, AC, Noise Reject, HF Reject, LF Reject
Trigger Sensitivity
(Edge Trigger Type)
DC(CH1,CH2):
1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;
DC(EXT):
200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;
DC(EXT/5):
1V from DC to 100MHz;1.75V from 100MHz to 200MHz;
AC: Attenuates signals below 10Hz;
HF Reject: Attenuates signals above 80kHz
LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz
Trigger Level Range
CH1/CH2: ??8 divisions from center of screen;
EXT: ??1.2V;
EXT/5:??6V
Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ??20ns
CH1/CH2: 0.2div x volts/div within ??4 divisions from center of screen;
EXT: ?? (6% of setting + 40mV);
EXT/5: ?? (6% of setting + 200mV);
Set Level to 50%(typical)
Operates with input signals ??50Hz
Video Trigger
Video Trigger Type
CH1, CH2: Peak-to-peak amplitude of 2 divisions;
EXT: 400mV;
EXT/5: 2V
Signal
Logistics information
Our products are located in Hong Kong, China, and the logistics speed depends on your specific location. According to our experience, it usually takes about 15-20 days of transportation time
CONTACT US
If you have questions or concerns then please do not hesitate to get in contact with us.
We would love to hear from you, contact us on:
whatsapp:+8613625959351
RETURNS POLICY
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.
Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.
Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.
SHIPPING
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.
Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.
Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.
How to choose the correct size:
Step 1 Please measure your foot length carefully.
Step 2 Please choose the correct size according to your foot length and chinese size.
For example, If your foot length is 255 mm , you should choose the size 8.
Step 3 If you\'re not sure of the correct size, you can click chat with us!
WHATSAPP:+8613625959351