    EC-316 is a new high-precision EC tester, which can be used to measure soil EC and check the condition of the soil. With automatic temperature compensation function, it is less affected by ambient temperature. Widely used, suitable for aquariums, swimming pools, laboratory soils, hydroponics, food processing and animal husbandry.

    Too high or too low soil EC will hinder the growth of crops, different plants have different suitable soil EC according to the characteristics of fertilizer demand and growth stage

         

    

    Specification:

         Measuring range: 0-4.00 mS / cm

     Resolution: 0.01 mS/cm

     Accuracy: ±2% FS

     Display: 4-digit LCD

     Environment: Humidity: <95%

     Automatic temperature compensation: 0℃-50℃

     Power supply: 4×1.5V (AG13) (not include)

     Size: 260mm×22mm×20mm

     Weight: 90 grams

    

         

    

    Packing list:

    1 * EC-316 soil EC tester

    1 *English manual

    1 *Small screwdriver

         

    

    Steps:

    1.Press the ON/OFF button to turn on the meter.

    2.Place the probe to the required depth and soak the soil as needed

 Use deionized water.

    3.Wait for the reading to stabilize.

    4.After use, rinse the electrode with water to reduce pollution.

Press the OFF button to turn off the meter

.

         

    

    Calibration:

    1. Immerse the meter in distilled water. Activate it after a few hours.

    2. Immerse the meter in the calibration solution of 1413 u s/cm. Stir gently

    3. Let the reading stabilize, and turn the calibration trimmer with a small screwdriver until the display shows "1.41"

    4. Rinse the electrode with distilled water, and then absorb the electrode with filter paper.

         

    

    FAQ

    Q: Can the product be calibrated by itself? Do you provide calibration fluid?

    Answer: Yes, you can calibrate the product yourself, but EC calibration fluid is not distributed. You need to purchase EC calibration solution yourself. The more you pursue accuracy, the more frequently you need to calibrate the product in a short period of time.

         

    

    Q: Does the product distribute batteries? What type of battery?

    Answer: No(pls buy it on your local store ,thanks), the battery type is 4x1.5V (AG13)

    

         

    

         

     

    

   

  

  

 



 


RETURNS POLICY

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

SHIPPING

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

How to choose the correct size:

Step 1 Please measure your foot length carefully.

Step 2 Please choose the correct size according to your foot length and chinese size.

For example, If your foot length is 255 mm , you should choose the size 8.

Step 3 If you\'re not sure of the correct size, you can click chat with us!

WHATSAPP:+8613625959351

Have Questions?Ask An Expert
EC-316 Digital Direct Soil EC Tester ATC Conductivity Meter EC Meter Aquarium Swimming Pool Hydroponic Laboratory 0-4.00 mS/cm
You have successfully subscribed!