      Functions:

  

 

 Measurement of AC leakage current, higher harmonic current, phase, power energy, power factor.

      

  

  Features:

     1.Split type structure design, no need to interrupt the power supply and disconnect the circuit in testing, easy to carry and especially suitable for on-site online testing. Non-contact measurement, easy to operate, fast, safe and reliable. 

   2.Adopts Permalloy core and CT double-layer shielding technology, with high performance and high accuracy, high anti-interference ability, suitable for complex interference environment. 

   3.Measure the leakage current of cable and electrical equipment when clamping the hot wire and zero wire together at the same time 

   4.Output current or voltage signal. 

   5.The range, transformation ratio, output interface of the sensor can be customized according to customer requirements. 

   6.Insulating strength: AC3700V/ms ( between the core and coil) 

   7.Safety class: CATⅢ600V 

   8.Working temperature: -15°C~50°C

  

 



Specifications:

      Function

   Measurement of AC current, leakage current, high order harmonic current, phase, power energy, power, power factor

       Test mode

   Split Type CT

       CT Size

   Φ40mm((Through the heart of wires by 40mm)

       Range

   0.00mA~60A (AC)

       Resolution

   0.01mA (AC)

       Accuracy

   ±1.0%FS(23℃±2℃, below 70%RH, keep the wire be in the center of clamp)

       Coils Turn

   Standard 800:1(Customize is allowed)

       Phase Error

   ≤2℃(50Hz/60Hz; 23℃±2℃)

       Reference Load

   RL: 0~100mA≤500Ω; 0-1A≤50Ω; 0-10A≤5Ω; 0~60A≤0.5Ω

       Sheild

   Double shielded, for complex interference environment

       Output Mode

   Current induction output(Take the voltage can be an external load resistance (RL)

       Output Interface

   Output terminals (S1, S2 coil tap end, GND screen)

       Output Wire Length

   2m(Customize is allowed)

       Electric Field Interference

   About 5mA when the external electric field 100A, 10mm nearby

       Measured Wire Position

   Approximately in the center of the closed core

       Current Frequency

   45HZ-60Hz(when measuring big current)

       Frequency Feature

   10Hz~100kHz

       Voltage of circuit

   Below AC 600V

       Dimension

   95mmx98mmx31mm 

       Weight

   About 200g

       Working Environment

   -20℃ ~ 50℃; below 80%rh

       Storage Environment

   -10℃ ~60℃; below 70%rh

       Insulation Strength

   AC 2KV/rms.(between the core and shell)

       Safety Rules

   IEC1010-1,IEC1010-2-032,Pollution degree:2 CAT Ⅲ(600V)  

   


RETURNS POLICY

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

SHIPPING

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

How to choose the correct size:

Step 1 Please measure your foot length carefully.

Step 2 Please choose the correct size according to your foot length and chinese size.

For example, If your foot length is 255 mm , you should choose the size 8.

Step 3 If you\'re not sure of the correct size, you can click chat with us!

WHATSAPP:+8613625959351

Have Questions?Ask An Expert
ETCR040K 60A Current Meter Split Core Transformer Clamp Sensor
You have successfully subscribed!