{"product_id":"etcr2800c-non-contact-grounding-resistance-online-tester-circuit-resistance-tester","title":"ETCR2800C Non-Contact Grounding Resistance Online Tester, Circuit Resistance Tester","description":"\u003cdiv\u003e\u003cspan\u003e\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e Features:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   *ETCR2800C Multifunction Non-Contact Resistance Online Tester is our company devotes ourselves to Grounding resistance test technical research’s another new high-tech product for more than ten years. Detector adopts weather fastness material manufacture, temperature resistance, cold-resistant, corrosion prevention, fire prevention. Detector’s structure is rigorous and firm, against rain, dustproof, installation and use outdoors. Non-contact measurement, safe and reliable, Ease of installation. Grounding down lead is directly through the detector perforation, Will not affect lightning protection grounding effect and the normal operation of the facilities. Ensure high-accuracy, high stability and high reliability of long time on-line monitoring outdoors, underground mine and indoors. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   *ETCR2800C Multifunction Non-Contact Resistance Online Tester is equipped with LCD display and alarm light, which can observe grounding resistance value at any times and set the alarm critical val. Alarm light will flash when measured value is beyond pre-set critical value. Detector applies to electric transmission line pole ground connection, underground mine device ground connection, meteorological lightning protection grounding connection, petrochemical engineering ground connection, communication ground connection, rail facility ground connection, building the warehouse ground connection, electrical equipment ground connection etc.. Detector provides power supply and RS485 signal interface, and standard MODBUS-RTU communication protocol，which user can do secondary development to realize remote monitoring. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   *ETCR2800C’s LCD shows measured value directly, also sets up Detector’s alarm critical value, and possess audible and visual alarming function, which is very suitable to Independent installation and use when it needn’t form a network. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Technical Specifications:  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                   Functions       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Return circuit ground resistance, metallic return connection resistance, grounding conditions on-line monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Power Supply       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      6VDC~9VDC, 50mA Max.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Resistance Range       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      0.01Ω~200Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Resolution       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      0.001Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Display Range       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      0.00Ω～500Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Accuracy       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      ±2%rdg±3dgt(20℃±5℃, below70%RH)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Grounding Wire Perforation Size       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      60mm×30mm, closed mode (60mm×4mm steel flat or external diameterФ30mm electric cable)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Overflow Indication       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     When show value is beyond 500Ω, systems software and LCD show “OLΩ” sign.       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Connecting Line       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      A one meter long wire (5cores shielded wire)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Connection Identifier       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Red\/brown---power supply input anode;       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Black--- power supply input cathode.       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Blue---RS485 signal anode;       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Grey---RS485 signal cathode;       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               White--- analog grounding (power supply input cathode can connects with analog grounding by short circuit connection)       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Communication Protocol       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      RS485 standard MODBUS-RTU communication protocol\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Alarm Indication       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Detector Audible and visual alarm instructions\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Alarm Setting       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Detector panel setting\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Data Display       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      4digits LCD direct indication\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               LCD Dimensions       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      47mm×28.5mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Detector Dimensions       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      175mm×170mm×130mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Installing Screw Hole Size       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Φ8mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Quality       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Detector: 960g\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Working Temperature and Humidity       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      -10℃~ 45℃; 20％RH ~ 90％RH\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Humiture Error       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Within 5%\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Shift       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Automatic shift\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               GND Interference Current       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Prohibited\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               External Magnetic Field       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      ＜40A\/m\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               External Electric Field       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      ＜1V\/m\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Single Measurement Of Time       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      About 0.5 second\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Power Consumption       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      50mA Max.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Installation       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Grounding wire through Detector centre bore\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Level Of Protection       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      IP65\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Installation Requirements       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Avoid rain and water logging\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Power Supply Mode       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      External power supply (Equipped by user)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003c\/span\u003e\u003c\/div\u003e","brand":"mickcara","offers":[{"title":"ETCR2800C","offer_id":41383210254473,"sku":"03208-1","price":544.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0365\/2131\/2393\/files\/d83e4211c63987b764b291e513b93882.jpg?v=1694933968","url":"https:\/\/mickcara.com\/products\/etcr2800c-non-contact-grounding-resistance-online-tester-circuit-resistance-tester","provider":"mickcara","version":"1.0","type":"link"}