{"product_id":"etcr2900-online-earth-resistance-tester-contact-line-ground-resistance-tester","title":"ETCR2900-Online Earth Resistance Tester Contact-line Ground Resistance Tester","description":"\u003cdiv\u003e\u003cspan\u003e\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   1.ETCR2900 Online Earth Resistance Tester is our company devotes ourselves to Grounding resistance test technical research’s another new high-tech product for more than ten years. Adopting precise 3-wire or simple 2-wire method for ground resistance measurement, average value rectification method for ground voltage measurement online testing and real-time monitoring. The user can select RS232 or RS485 communication, according to the protocol MODBUS, the user also can proceed secondary development, build network, realization of remote multipoint online monitoring etc. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   2.ETCR2900 Online Earth Resistance Tester composed of the detector and the monitoring software. The large LCD display of the detector is very intuitive. Setting the alarm thresholds and audible and visible alarm indicator are available. The material of the shell has the characteristic of resistance to high low temperature, corrosion prevention, inflaming retarding etc, ensure high-accuracy, high stability and high reliability of long time on-line monitoring outdoors, underground mine and indoors. The monitor software can real-time display the values of measured ground resistance and voltage. The user also can set the automatic monitoring interval time by the detector or the monitor software, the range of interval time is 1-999 hours. The automatic recording data can be generated reports, it is convenient to preservation, historical data query, print, analysis. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   3.ETCR2900 Online Earth Resistance Tester apply to transmission line tower grounding, underground mine equipment grounding, meteorological lightning proof grounding, petrochemical grounding, communication grounding, distribution substation grounding, railway equipment grounding, building warehouse grounding, electrical equipment grounding etc. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   II. Technical Specification \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Function     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               On-line monitoring ground resistance, ground voltage, equipotential connection resistance, low resistance.     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Power Supply     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Standard: 12V±1VDC, 150mA Max.     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e           Optional: 24V±1VDC.     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                           \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Range     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Accuracy     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Resolution     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Resistance     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               0.01Ω~20Ω     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               ±1%rdg±3dgt     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e           (auxiliary ground resistance 100Ω±5%, voltage to ground\u0026amp;lt;10V)     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               0.01Ω     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     0.1Ω~200Ω     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               0.1Ω     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     1Ω~2000Ω     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               1Ω     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Voltage     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               0~600V AC     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               ±1%rdg±3dgt     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               1V     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Measure Mode     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Precise 3-wire measurement, simple 2-wire measurement.     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Measure Method     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Ground resistance: rated current change-pole method, measured current 3mA Max, 820Hz;     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e           Voltage to ground: average value rectification method.     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Data Mode     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Mean.     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Display Mode     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               4-digital super-large LCD.     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Measuring Indicator     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               During measurement, LCD count down display.     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     LCD Size     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               128mm×75mm;     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e           Display field: 124mm×67mm.     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Dimension     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               L×W×H: 190mm×117mm×54mm.     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Measure Rate     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Voltage to ground: about 2 times\/second; ground resistance: about 30 seconds\/time.     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Measure Times     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Over 5000 times(Measuring 10Ω for one time and take a pause for 30s).     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Line Voltage     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Measuring voltage to ground: measuring below AC 600V.     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Instrument Interface     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Pluggable terminal blocks: 9 pin connector.     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Communication Method     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               RS485 (or optional RS232).     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Communication Line     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               USB to RS485 communication line( or optionalUSB to RS232 communication line).     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Range Shift     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Automatically.     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Data Storage     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               400 sets, flash display FULL icon to indicate storage is full.     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Interval Time     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Range of automatic monitoring interval time: 1-999 h.     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Data Access     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Data read function: READ icon display.     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Overflow Display     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Exceeding measuring range overflow function: OL icon display.     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Power Consumption     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Backlit : 20mA Max.     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Standby: 25mA Max.     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Measurement: 70mA Max.     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Alarm     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Audible and visible alarm.     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Power supply Voltage     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               When power supply voltage decreases to about 7.8V, will display, reminding to replace the power.     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Weight     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Detector: 450g.     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Working Humiture     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               -10°C~40°C; below 80%rh.     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Storage Humiture     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               - -20°C~60°C; below 70%rh.     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Overload Protection     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Measurement ground resistance: E-P, E-C between each interfaces AC 280V\/3 sec.     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Insulation Value     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Over 10MΩ(between circuit and enclosure 500V).     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Withstand Voltage     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               AC 3700V\/rms. (Between circuit and enclosure).     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Electromagnetism     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               IEC61010-4-3,Radio frequency electromagnetic field≤1V\/m.     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     Applicable Safety Rules     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               IEC61010-1, IEC1010-2-31, IEC61557-1,5, IEC60529(IP54), Pollution degree 2, CAT III 300V.     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   The batteries not included package \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003c\/span\u003e\u003c\/div\u003e","brand":"mickcara","offers":[{"title":"ETCR2900","offer_id":41383213072521,"sku":"03178-1","price":555.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0365\/2131\/2393\/files\/c670be4e86a4e7e3fd442a13e02bd4ef.jpg?v=1694934189","url":"https:\/\/mickcara.com\/products\/etcr2900-online-earth-resistance-tester-contact-line-ground-resistance-tester","provider":"mickcara","version":"1.0","type":"link"}