{"product_id":"etcr3200-double-clamp-earth-resistance-meter-ground-resistance-multifunction-ground-resistance-tester-earth-resistance-tester","title":"ETCR3200 Double Clamp Earth Resistance Meter Ground Resistance Multifunction Ground Resistance Tester Earth Resistance Tester","description":"\u003cdiv\u003e\u003cspan\u003e\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e ETCR3200 Double Clamp Grounding Resistance Tester is specially design for the measurement of earth resistance, soil resistivity, earth voltage, leakage current of grounding line, AC current, DC resistance. Adopting the latest digital technology, precise 4-pole, 3-pole and simple 2-pole method, selection method, double clamp method to measure grounding resistance, for earth resistance measurement; large caliber clamp design, can use to measure the grounding system which adopt large-scale down conductor; can flexibly and precisely measure the value of grounding resistance in every complicated situation like single point grounding, grounding mesh; it is not need to disconnect any parallel connection pole when measuring parallel-grounding, and massively improve the convenience when measuring. Importing FFT and AFC technology, with a unique function of anti-interference capability and the ability to adapt to the environment, consistency of repeat testing, to ensure high precision, high stability and reliability for prolonged measure, which is widely used in electric power, telecommunications, meteorology, oil field, construction, lightning protection, industrial electrical equipment and other earth resistance, soil resistivity, earth voltage, AC voltage measurement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e ETCR3200 Double Clamp Grounding Resistance Tester is composed of host machine, monitoring software, testing wires, auxiliary ground pillars, communication wires and others. The large LCD display of host machine is with blue backlight and bar graph indicating that can be seen clearly. At the same time it can store 2000 sets of data, fulfilling historical inquiry and online real-time monitoring through monitoring software, dynamic display, and alarm indicator, auto-shut down and with the functions like historical data access, reading, preservation, report forms, printing and so on.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e Specifications:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e Base Conditions and Working Conditions\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Influence Quantity    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            Base Condition    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            Working Conditions    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            Remark    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Ambient Temp    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            23C±1C    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            -10C-40C    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            ----    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Ambient Humidity    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            40%-60%    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            \u0026amp;lt;80%    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            ----    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Working Voltage    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            9V±0.1V    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            9V±1.5V    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            rC.rP    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Auxiliary Earth Resistance    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            \u0026amp;lt;100Ω    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            \u0026amp;lt;30kΩ    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            ----    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Interference Voltage    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            None    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            \u0026amp;lt;20V    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            ----    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Interference Current    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            none    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            \u0026amp;lt;2A    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                 \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Electrode Distance when measuring R    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            a\u0026amp;gt;5d    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            a\u0026amp;gt;5d    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            ----    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Electrode Distance when measuring ρ    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            a\u0026amp;gt;20h    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            a\u0026amp;gt;20h    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            ----    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e              \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Function    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   4-pole, 3-pole and simple 2-pole, selection, double clamp method measure grounding resistance, soil resistivity; Measurement of earth voltage, AC voltage, leakage current of AC current\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Power Supply    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   DC 9V(Zn-Mn dry battery R14S 1.5V 6 PCS, continuous standby for 300 hours )\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Caliber of clamp    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Φ68mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Measurement Range    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Selection method: 0.00Ω-3000Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Double clamp method: 0.00Ω-9000kΩ\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       2\/3\/4 pole method:0.00Ω~30.00kΩ\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Soil resistivity:0.00Ω~9000kΩ\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       DC resistance:0.00Ω~30.00kΩ\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Earth voltage:0.0V~100.0V\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       AC current:0.00mA~600A\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Measuring Mode    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Precise 4-pole measurement, 3-pole measurement, simple 2-pole measurement, selection method, double clamp method measure grounding resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Measuring Method    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            2\/3\/4 pole method: change-pole method, measurement current 20mA Max    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         Selection method: change-pole method, measurement current 20mA Max    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         Double clamp method: disconnect mutual inductance method, measurement current 1mA Max    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         Soil Resistivity: 4-pole measurement (Wenner method)    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         Earth Voltage: average rectification(between P(S)-ES)    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         AC current: mutual inductance method    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Test Frequency    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   128Hz\/111Hz\/105Hz\/94Hz(AFC)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Short-circuit Test Current    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   AC 20mA max\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Open-circuit Test Current    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   AC 40V max\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Test Voltage Wave    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Sine wave\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Electrode Distance Range    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Can be set 1m-100m\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Shift    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   automatic shift\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Backlight    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Blue screen backlight, suitable for dim places\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Display Mode    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   4-digital super-large LCD display, blue screen backlight\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Measuring Indicator    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   During measurement, LED flash indicator, LCD countdown display, progress bar indicator\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                LCD Frame Dimension    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   128mm×75mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                LCD Window Dimension    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   124mm×67mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Dimension    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   L×W×H: 215mm×190mm×95mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Standard Test Wire    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   4 wires: each for red 20m, black 20m, yellow 10m, and green 10m\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Simple Test Wire    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   2 wires: each for red 1.6m and black 1.6m\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Auxiliary Earthing Rod    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   4 wires: Φ10mm×150mm Over 5000 times (Short-circuit test, interval time should be at least 30 seconds)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Measuring Rate    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Voltage to ground: about 2 times\/second\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Current to ground: about 2 times\/second\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Earth resistance, soil resistivity: about 5 seconds\/time\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Measuring Times    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Over 5000 times (Short-circuit test, interval time should be at least 30 seconds)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                RS232 Interface    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   RS232 interface, software supervision, storage data can be uploaded to computer, saved or printed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Communication Wire    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   One piece of RS232 communication wire, with length 1.5m\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Data Storage    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   2000 sets, “MEM” icon storage indicator, flash display “FULL” icon to indicate storage is full\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Data Hold    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Data hold function: “HOLD” icon display\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Data Read    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Data read function: “READ” icon display\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Overflow Display    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Exceeding measuring range overflow function: “OL” icon display\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Interference Test    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Recognize interference signal automatically, “NOISE” icon display when interference voltage exceed 5V\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Auxiliary Earthing Test    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Can measure auxiliary earth resistance, 0.00KΩ-30kΩ(100R+rC\u0026amp;lt;50kΩ, 100R+rP\u0026amp;lt;50kΩ)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Alarm Function    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   When measuring value exceeds alarm setting value, there is “Toot-toot-toot” alarm hint\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Battery Voltage    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   When battery voltage decreases to about 7.5V, battery voltage low icon     will display, reminding to replace battery.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Auto-shut off    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Automaticlly shut down 15minutes after booting\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Power Consumption    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Standby: about 20mA (Backlight shut off)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Boot and with backlight: about 45mA (25mA without backlight)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Measurement: about 100mA (Backlight shut off)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Weight    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Total weight: 8.0kg (including package)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Tester: 1653g (including battery)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Testing wires: 1560g\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Auxiliary earthing rods: 935g (4pcs)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Working Temperature \u0026amp;amp; Humidity    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   -10C-40C, below 80%rh\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Storage temperature \u0026amp;amp; humidity    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   -20C-60C, below 70%rh\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Overload Protection    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Measuring earth resistance: between each interfaces of C(H)-E.P(S)-ES,AC 280V\/3 seconds\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Insulation Resistance    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Over 20MΩ (between circuit and enclosure it is 500V)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Withstanding Voltage    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   AC 3700V\/rms. (Between circuit and enclosure)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Electromagnetic Features    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   IEC61326(EMC)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Protection Type    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   IEC61010-1 (CAT III 300V. CAT IV 150V. Pollution 2), IEC61010-031, IEC61557-1 (Earth resistance), IEC61557-5 (Soil resistivity), JJG 366-2004\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Intrinsic error and performance indicators under base conditions  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                           Function      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Measurement Range      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Intrinsic Error      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Resolution      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          2\/3\/4 pole method measure earth resistance      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             (R)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.00Ω-30.00Ω      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     ±2%rdg±3dgt\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.01Ω      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          30.0Ω-300.0Ω      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     ±2%rdg±3dgt\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.1Ω      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          300Ω-3000Ω      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     ±2%rdg±3dgt\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  1Ω      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          3.00kΩ-30.00kΩ      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     ±4%rdg±3dgt\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  10Ω      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Selection method to measure grounding resistance(R)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.00Ω-30.00Ω      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     ±2%rdg±3dgt\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.01Ω      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          30.0Ω-300.0Ω      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     ±2%rdg±3dgt\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.1Ω      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          300Ω-3000Ω      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     ±2%rdg±3dgt\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  1Ω      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Double clamp method to measure grounding resistance(R)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.01Ω-1.00Ω      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     ±10%rdg±5dgt\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.1Ω      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          1.0Ω-10.0Ω      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     ±10%rdg±5dgt\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.01Ω      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          10Ω-100Ω      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     ±10%rdg±5dgt\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  1Ω      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Soil Resistivity      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             (ρ)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.00Ωm-99.99Ωm      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  According to the precision of R      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             (ρ=2πaR      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             a:1 m-100m,      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             π=3.14)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.01Ωm      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          100.0Ωm-999.9Ωm      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.1Ωm      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          1000Ωm-9999Ωm      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  1Ωm      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          10.00kΩm-99.99kΩm      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  10Ωm      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          100.0kΩm-999.9kΩm      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  100Ωm      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          1000kΩm-9000kΩm      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  1kΩm      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Earth Voltage(50Hz\/60Hz)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  AC 0.0-600V      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ±2%rdg±3dgt      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.1V      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          AC current(50Hz\/60Hz)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.0mA-600.0A      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ±2%rdg±3dgt      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.0mA      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAccessory\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Tester\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   1 PC\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Tester Bag\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   1 PC\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       clamp\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   2PC\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Auxiliary Earthing Rod\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   4 PCS\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Standard testing Wire\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   4 wires: each for red 20m, black 20m, yellow 10m, and green 10m\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Simple testing Wire\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   2 wires: each for red 1.6m and black 1.6m\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Zinc-manganese Dry Battery\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   6 PCS(R14S 1.5V) (not included package)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Monitoring Software Disk\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   1 Copy\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       RS232 Communication Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   1 PC\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Manual\/Warranty Card\/Qualification Certificate\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   1 Copy\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003c\/span\u003e\u003c\/div\u003e","brand":"mickcara","offers":[{"title":"ETCR3200","offer_id":41382252347529,"sku":"03030-1","price":1322.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0365\/2131\/2393\/files\/aebd4ed6445959e248b5480439b9ba0d.jpg?v=1694853944","url":"https:\/\/mickcara.com\/products\/etcr3200-double-clamp-earth-resistance-meter-ground-resistance-multifunction-ground-resistance-tester-earth-resistance-tester","provider":"mickcara","version":"1.0","type":"link"}