{"product_id":"etcr3200c-test-tool-100-240v-resistance-tester-waterproof-double-clamp-ground-meter","title":"ETCR3200C Test Tool 100-240V Resistance Tester Waterproof Double Clamp Ground Meter","description":"\u003cdiv\u003e\u003cspan\u003e\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e product functions：\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e 1. It can be used to test ground resistance, DC resistance, ground resistance, AC resistance and soil resistivity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e2. The resistance tester supports accurate test, simple test, selective test and other test methods.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e3. Soil resistivity tester is made of high‑quality materials, durable and long service life.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e4. After 10 minutes of starting, it will automatically shut down to save resources and power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e5. It has battery voltage prompt and overload protection function to ensure the safety of the operator.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   product specifications：\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e               Model\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     ETCR3200C Double Clamp Grounding Resistance Tester\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             2\/3\/4 pole Method Measure Grounding Resistance(R)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Range:0.00Ω~30.00Ω;         Resolution:0.01Ω;      Accuracy:±2%rdg±3dgt\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Range:30.0Ω~300.0Ω;         Resolution:0.1Ω;       Accuracy:±2%rdg±3dgt\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Range:300Ω~3000Ω;          Resolution:1Ω;         Accuracy:±2%rdg±3dgt\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Range:3.00kΩ~30kΩ;          Resolution:10Ω;        Accuracy:±4%rdg±3dgt\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Selection Method Measure Grounding Resistance(R)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Range:0.00Ω~30.00Ω;         Resolution:0.01Ω;      Accuracy:±2%rdg±3dgt\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Range:30.0Ω~300.0Ω;         Resolution:0.1Ω;       Accuracy:±2%rdg±3dgt\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Range:300Ω~3000Ω;          Resolution:1Ω;         Accuracy:±2%rdg±3dgt\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Earth Voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Range:0.0~100V AC;          Resolution:0.1V;        Accuracy:±2%rdg±3dgt\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             AC current\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Range:0.00mA~600.0A        Resolution:0.0mA;      Accuracy:±2%rdg±3dgt\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Soil Resistivity\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e(ρ)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Range:0.00Ωm~99.99Ωm;      Resolution:0.01Ωm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Accuracy :According to the precision of R\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e(ρ=2πaR, a:1 m-100m, π=3.14)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Range:100.0Ωm~999.9Ωm;     Resolution:0.1Ωm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Range:1000Ωm~9999Ωm;      Resolution:1Ωm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Range:10.00kΩm~99.99kΩm;   Resolution:10Ωm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Range:100.0kΩm~999.9kΩm;   Resolution:100Ωm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Range:1000kΩm~9000kΩm;    Resolution:1kΩm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Measurement Method\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     2\/3\/4 pole method measurement: Change-pole method, measure current 20mA Max\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSelection method measurement: Change-pole method, measure current 20mA Max\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDouble clamp method measurement: mutual inductance method, measure current 1mA Max\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSoil Resistivity: Wenner 4-pole measurement method\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eVoltage to ground: Average rectification(between P(S)-ES interface)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAC current: Clamp mutual inductance method\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Power Supply\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     DC 7.4V 2600mAh rechargeable lithium battery\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Test Frequency\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     128Hz\/111Hz\/105Hz\/94Hz(AFC)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Short-circuit Test Current\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     AC 20mA max\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Open-circuit Test Current\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     AC 40V max\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Data Storage\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     2000 groups\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Test Voltage Wave\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Sine wave\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Data Hold\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Data hold function: “HOLD” symbol display\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Data Access\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Data access function: “READ” symbol display\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Overload Display\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Exceed measure range overflow function: “OL” symbol display\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Current Clamp\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Caliber:φ68mm;Connecting line:2M\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Tester Dimension\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     280mm(L)×260mm(W)×160mm(H)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             LCD Dimension\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     LCDFrame Dimension: 128mm×75mm;LCD Display Dimension:124mm×67mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Total Weight\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     6690g(include package)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Test Wires\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Red 20m, black 20m, yellow 10m, green 10m, red 1.6m, black 1.6m (total 6 pcs wires)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Working Current\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Standby: around 45mA (Backlight close 25mA); Measurement:100mA (Backlight close)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Auxiliary Ground Rod\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     4PCS:φ10mm×150mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             USB Interface\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     With USB interface,software monitoring, storage data can be uploaded to computer, saved and printed\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Interference Test\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Automatic recognition of interference signal , interference voltage higher than 5V will display  “NOISE” symbol\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Auxiliary Grounding Test\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Auxiliary ground resistance test function: 0.00kΩ~30kΩ(100R+rC\u0026amp;lt;50kΩ,100R+rP\u0026amp;lt;50kΩ)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Alarm Function\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Measure value exceed alarm setting value, will \"Toot-toot-toot\" alarm indication\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Battery Voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     While battery voltage decreases to around DC 7.2V±0.1V, will display low battery voltage symbol“”, and remind to replace the battery\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Overload Protection\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Measuring earth resistance: between each interfaces of C(H)-E,P(S)-ES, AC 280V\/3 seconds\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Protection Level\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     IP65(close the case status)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Accessories\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Tester:1PC;Current Clamp Sensor:2pcs; Ground Rod:4PCS;  Testing wires:6PCS; USB data transmission cable:1PCS; Software CD:1 COPY; Tester bag:1PCS; Special charger:1PCS\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003c\/span\u003e\u003c\/div\u003e","brand":"mickcara","offers":[{"title":"ETCR3200C","offer_id":41382145327241,"sku":"02973-1","price":1022.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0365\/2131\/2393\/files\/1d604772b2005fb7897af32bf2d25979.jpg?v=1694834412","url":"https:\/\/mickcara.com\/products\/etcr3200c-test-tool-100-240v-resistance-tester-waterproof-double-clamp-ground-meter","provider":"mickcara","version":"1.0","type":"link"}