{"product_id":"etcr4300-three-phase-meter-price-with-digital-phase-volt-ampere-meter","title":"ETCR4300 Three Phase Meter Price with Digital Phase Volt-Ampere Meter","description":"\u003cdiv\u003e\u003cspan\u003e\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eETCR4300 Three Phase Meter Price with Digital Phase Volt-Ampere Meter\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e Features:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   1. In the measured circuit is open under the condition of simultaneous measurement of three-phase AC voltage, current, voltage, current, phase phase voltage and current phase, frequency, phase, active power, reactive power, apparent power, power factor, current vector and discrimination, transformer group, line inductive and capacitive circuit two, test circuit and bus differential protection system, readout phase relationship between differential protection groups CT, wiring check meter is correct or not, the maintenance of the line equipment etc.. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   2. Intelligent design, reduce the complexity of the operation, reduce the possibility of false operation, with high precision, high stability, low power consumption, easy to use. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   3. The tip of a small jaw shape is suitable for measuring the cable in crowded places. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Four The test line with power cable, rod plug and holder have insulation protection. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Five Insulated anti slip jacket. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Six The use of large LCD display, white screen backlight, display at a glance. High precision, high stability, low power consumption, easy to use. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Seven Equipped with USB-RS232 interface, can store 500 sets of data, upload the data to the computer through the system software, easy to read, save, report, print the historical data, etc.. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Specification: \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                            nfluence Quantity      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Base Condition      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Working Condition      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Remark      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Ambient Temperature      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  23c±1c      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  -10c-40c      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ----      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Ambient Humidity      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  40%-60%      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  \u0026amp;lt;80%      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ----      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Signal Waveform      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  sine wave      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  sine wave      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  β=0.01      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Signal Frequency      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  50HZ±1HZ      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  45HZ-65HZ      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ----      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Meter Working Volt      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  9V±0.1V      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  9V±1.5V      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ----      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Current Amplitude in Phase\/Frequency\/Phase SequenceTest      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  1A±0.2A      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  2mA-20A      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ----      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Voltage Amplitude in Phase \/ Frequency\/ Phase Sequence Test      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  100V±20V      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  10V-600V      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ----      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Current Amplitude in Power \/ Power Factor Test      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  1A±0.2A      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  20mA-20A      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ----      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Voltage Amplitude in Power \/ Power Factor Test      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  100V±20V      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  10V-600V      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ----      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          External Electric Magnetic Field      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  To be avoided      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Measured Wire Position      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Measured wire at approximately the geometric center of the clamp\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  2 Intrinsic Error and Performance Indicators under Base Conditions:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                           Category      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Measurement Range      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Resolution      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Intrinsic Error      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Voltage      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  AC 0.0V-600V      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.01V      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ±(1.5%rdg+3dgt)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Current      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  AC 0.0mA-20.0A      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.1mA      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ±(1.5%rdg+3dgt)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Phase      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.0°-360°      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.1°      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ±1°      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Active Power      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.0W-12kW      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.1W      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ±(3%rdg+3dgt)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Reactive Power      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.0VAR-12kVAR      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.1VAR      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ±(3%rdg+3dgt)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Apparent Power      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.0VA-12kVA      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.1VA      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ±(3%rdg+3dgt)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Frequency      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  45HZ-65HZ      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.01HZ      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ±(2%rdg+3dgt)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Power Factor      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  -1-+1      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.001      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ±0.03      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  3 General Specification:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                           Function      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Simultaneous measurement of three-phase AC voltage, current, phase between voltage, phase between current, phase between voltage and current, frequency, phase sequence, active power, reactive power, apparent power, power factor, current vector sum, distinguish transformer wiring group, inductive and capacitive circuits, test second circuit and bus differential protection systems, read the phase relationship between CTs of the differential protection, check the meter wiring right, repair lines and equipment, etc.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Power      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     DC9V alkaline batteries(1.5V AA×6)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Consumption      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     About 80mA at most with enabled backlight, battery working continuously for about 10 hours\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             About 5mA with disabled backlight, battery working continuously for about 16 hours\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Display Mode      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     LCD display, 240dots×160dots\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Meter Size      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Length, Width, Height 196mm×92mm×54mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Clamp Size      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     acuminate current clamp:7.5mm×13mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Measurement Range      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             (automatic shift)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     AC Voltage0.00 V-600V (automatic shift)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             AC Current 0.0mA-20.0A (automatic shift)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Phase 0-360°\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Frequency 45.00Hz-65.00Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Active Power 0.0W-12kW\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Reactive Power 0.0W-12kVAR\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Apparent Power 0.0W-2kVA\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Power Factor -1-+1\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Current Vector Sum 0mA-60.0A\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Resolution      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Voltage AC 0.01V\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Current AC 0.1mA\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Phase 0.1°\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Frequency 0.01Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Active Power 0.1W\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Reactive Power 0.1VAR\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Apparent Power 0.1VA\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Power Factor 0.001\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Current Vector Sum 1mA\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Phase Sequence      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Positive Phase Sequence U1 U2 U3 or I1 I2 I3 cursors blink in order from left to right      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Negative Phase Sequence U1 U2 U3 or I1 I2 I3 cursors blink in order from right to left      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Sample Rate      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     About 2 times\/second\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Data Hold      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Press HOLD key to keep data, \"DH\" symbol appears\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Data Storage      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     500 sets\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          RS232 Interface      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     USB-RS232 interface, download data to computer for analysis and management\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Automatic Shutdown      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Automatic shutdown about 15 minutes later after launching to reduce battery consumption\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Backlighting      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Suitable for dark place and nightly use\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Voltage Detection      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Low battery symbol appears to remind the replacement of battery when the battery voltage drops below 7.2V.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Weight      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Main Unit about 550g(with battery), acuminate current clamp about 170g×3, round current clamp about 185g×3, test line about 250g\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Test Line Length      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     1.5m\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Current Clamp Length      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     2m×φ5mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Working Temperature and Humidity      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     -10c-40c below 80%Rh\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Storage Temperature and Humidity      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     -10c -60c below 70%Rh\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Input Impedence      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Testing voltage the input impendence is 2MΩ\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Withstand Voltage      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Withstand 1000V\/50Hz sine wave AC voltage for 1 minute between the meter lines and shell; Withstand 500V\/50Hz AC voltage sine wave for 1 minute between the two voltage inputs\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Insulation      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     ≥100MΩ between meter lines and shell or between the two voltage inputs\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Structure      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Double insulation, with insulation vibration-proof sheath\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Safety Specifications      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     IEC61010-1 CAT iii 600V, IEC61010-031, IEC61326, 2 class of pollution\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Accessories      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Main Unit: 1 pc; Meter Box: 1 piece; Current Clamp: 3 pcs; Test Line: 4 pcs(yellow, green, red, black); RS232 Data Line: 1 pc; Disk: 1 pc;User Manual: 1 pc ; Guarantee Card: 1 pc; Certification: 1 pc.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003c\/span\u003e\u003c\/div\u003e","brand":"mickcara","offers":[{"title":"ETCR4300","offer_id":41382248448137,"sku":"03132-1","price":988.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0365\/2131\/2393\/files\/6e5faf5a95f640299c60918e83d0bfb8.jpg?v=1694853689","url":"https:\/\/mickcara.com\/products\/etcr4300-three-phase-meter-price-with-digital-phase-volt-ampere-meter","provider":"mickcara","version":"1.0","type":"link"}