{"product_id":"etcr4700-three-phase-digital-phase-volt-ampere-clamp-current-meter","title":"ETCR4700 Three Phase Digital Phase Volt-Ampere Clamp  Current Meter","description":"\u003cdiv\u003e\u003cspan\u003e\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eETCR4700 Three Phase Digital Phase Volt-Ampere Clamp Meter\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Features:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e        \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         The ETCR4700Three Phase Digital Phase Volt-Ampere Meter is a well-developed full-automatic, multi-functional, digital, intelligent meter specifically designed for field testing,featuring high accuracy, high stability, low power consumption, easiness to use and so on. It can directly measure AC voltage and AC current without opening the measured circuit, phases between three voltages, three currents and phase between the voltage and current; in addition, the power factor and power of the circuit can be indirectly measured, it can also be used to distinguish three-phase sequence, transformer wiring group, inductive and capacitive circuits, test second circuit and bus differential protection systems, read the phase relationship between CTs of the differential protection, check the meter wiring right, repair lines and equipment, etc.   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         The ETCR4700 Three Phase Digital Phase Volt-Ampere Meter has well designed shell mould made of newest material, attach with shakeproof, skidproof, high insulation sheath, has a 240dots×160dots LCD screen, all the test data display on the screen simultaneously, vector diagram indication, and looks exquisite and comfortable. Meter equipped with USB-RS232 interface, can store 1500 sets of data, through the system software upload stored data to the computer, implementing online real-time monitoring and historical inquires, dynamic display. Can read, save, report, print history data, etc.    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       The ETCR4700 Three Phase Digital Phase Volt-Ampere Meter (Intelligent Three Phase Digital Phase Volt-Ampere Meter) applies to electric power, petroleum chemical industry, metallurgy, railway, and meteorology, industrial and mining enterprises, scientific research institutions, measurement sector and so on. Especially for the electricity billing system and relay protection system.   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e           \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Specifications:   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eⅡ.Technical Specifications  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     1．Base Conditions and Working Conditions  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                           Influence Quantity      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Base Condition      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Working Condition      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Remark      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Ambient Temperature      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  23℃±1℃      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  -10℃～40℃      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ----      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Ambient Humidity      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  40%～60%      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ＜80%      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ----      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Signal Waveform      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  sine wave      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  sine wave      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  β=0.01      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Signal Frequency      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  50HZ±1HZ      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  45HZ～65HZ      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ----      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Meter Working Volt      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  9V±0.1V      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  9V±1.5V      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ----      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Current Amplitude in Phase\/Frequency\/Phase Sequence Test      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  1A±0.2A      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  2mA～20A      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ----      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Voltage Amplitude in Phase \/ Frequency\/ Phase Sequence Test      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  100V±20V      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  10V～600V      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ----      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Current Amplitude in Power \/ Power Factor Test      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  1A±0.1A      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.1A～400A      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ----      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Voltage Amplitude in Power \/ Power Factor Test      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  200V±2V      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  30V～600V      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ----      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          External ElectricMagnetic Field      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  To be avoided      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Measured Wire Position      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Measured wire at approximately the geometric center of the clamp      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     2．Intrinsic Error and Performance Indicators under Base Conditions  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                           Category      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Measurement Range      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Resolution      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Intrinsic Error      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Voltage      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  AC 0.0V～600V      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.01V      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ±(1.5%rdg+5dgt)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Current      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  AC 0mA～400A      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  1mA      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ±(1.5%rdg+5dgt)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Phase      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.0°～360°      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.1°      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ±3°      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Active Power      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.0W～240kW      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.1W      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ±(3%rdg+5dgt)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Reactive Power      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.0VAR～240kVAR      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.1VAR      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ±(3%rdg+5dgt)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Apparent Power      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.0VA～240kVA      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.1VA      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ±(3%rdg+5dgt)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Frequency      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  45HZ～65HZ      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.01HZ      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ±(2%rdg+5dgt)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Power Factor      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  -1～+1      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  0.001      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ±0.03      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     3．General Specification  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                           Function      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Simultaneous measurement of three-phase AC voltage, current, phase between voltage, phase between current, phase between voltage and current, frequency, phase sequence, active power, reactive power, apparent power, power factor, current vector sum, distinguish transformer wiring group, inductive and capacitive circuits, test second circuit and bus differential protection systems, read the phase relationship between CTs of the differential protection, check the meter wiring right, repair lines and equipment, etc.      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Power      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  DC9V alkaline batteries（1.5V LR6×6）      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Consumption      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  About 80mA at most with enabled backlight, battery working continuously for about 10 hours      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          About 5mA with disabled backlight, battery working continuously for about 16 hours      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Display Mode      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  LCD display, 240dots×160dots      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Meter Size      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Length, Width, Height：196mm×92mm×54mm      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Clamp Size      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  round current clamp:35mm×40mm      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Measurement Range      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             (automatic shift)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  AC Voltage：0.00 V～600V (automatic shift)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          AC Current：0mA～400A (automatic shift)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Phase：0～360°      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Frequency：45.00Hz～65.00Hz      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Active Power：0W～240kW      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Reactive Power：0W～240kVAR      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Apparent Power：0W～240kVA      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Power Factor：-1～+1      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Current Vector Sum：0A～1200A      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Resolution      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Voltage：AC 0.01V      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Current：AC 1mA      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Phase：0.1°      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Frequency：0.01Hz      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Active Power：0.1W      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Reactive Power：0.1VAR      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Apparent Power：0.1VA      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Power Factor：0.001      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Current Vector Sum：0.1A      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Phase Sequence      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Positive Phase Sequence：U1、U2、U3 or I1、I2、I3 cursors blink in order from left to right      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Negative Phase Sequence：U1、U2、U3 or I1、I2、I3 cursors blink in order from right to left      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          SampleRate      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  About 2 times\/second      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Data Hold      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Press HOLD key to keep data, \"DH\" symbol appears      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Data Storage      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  500 sets      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          RS232 Interface      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  USB-RS232 interface, download data to computer for analysis and management      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Automatic Shutdown      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Automatic shutdown about 15 minutes later after launching to reduce battery consumption      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Backlighting      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Suitable for dark place and nightly use      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Voltage Detection      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                   Low battery symbol “     \" appears to remind the replacement of battery when the battery voltage drops below 7.2V.      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Weight      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Main Unit about 550g（with battery），acuminate current clamp about 170g×3, round current clamp about 185g×3, test line about 250g      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Test Line Length      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  1.5m      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Current Clamp Length      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  2m×φ5mm      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Working Temperature and Humidity      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  -10℃～40℃； below 80%Rh      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Storage Temperature and Humidity      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  -10℃～60℃； below 70%Rh      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Input Impedence      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Testing voltage the input impendence is 2MΩ      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Withstand Voltage      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Withstand 1000V\/50Hz sine wave AC voltage for 1 minute between the meter lines and shell; Withstand 500V\/50Hz AC voltage sine wave for 1 minute between the two voltage inputs      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Insulation      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  ≥100MΩ between meter lines and shell or between the two voltage inputs      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Structure      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Double insulation, with insulation vibration-proof sheath      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          SafetySpecifications      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  IEC61010-1 CAT Ⅲ 600V, IEC61010-031, IEC61326, 2 class of pollution      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Accessories      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Main Unit: 1 pc; Meter Box: 1 piece; Current Clamp: 3 pcs; Test Line: 4 pcs(yellow, green, red, black); RS232 Data Line: 1 pc; Disk: 1 pc; Battery: 6 pcs(LR6)(not included package); User Manual: 1 pc ;Guarantee: 1 pc; Certification: 1 pc. Card      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003c\/span\u003e\u003c\/div\u003e","brand":"mickcara","offers":[{"title":"000","offer_id":41382247923849,"sku":"03146-1","price":988.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0365\/2131\/2393\/files\/94d3c734483eff1bc2a78b3f340700f6.jpg?v=1694853701","url":"https:\/\/mickcara.com\/products\/etcr4700-three-phase-digital-phase-volt-ampere-clamp-current-meter","provider":"mickcara","version":"1.0","type":"link"}