{"product_id":"etcr7000b-large-caliber-clip-on-ammeter-0-0a-2500a-current","title":"ETCR7000B large caliber clip on ammeter 0.0A~2500A current","description":"\u003cdiv\u003e\u003cspan\u003e\u003cp\u003e\u003cspan\u003eSpecifications:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFunction: AC leakage current and current test\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePower supply: 6V DC (LR6X4 alkaline dry batteries, used continuously for 12 hours)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTest mode: clamp CT, integration mode\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eJaw size:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e80mmX 80mm (clamp φ 80mm conductor, or 96mm X 4mm flat steel ground wire)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMeasurement accuracy (23C ± 3 ° C, below 70% RH, the conductor is in the center of the jaw):\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e0.00mA~300A: soil 1.5% soil 3dgt\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e300A~1200A: ± 2% ± 3dgt\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e1200A~2000A: ± 3% ± 3dgt\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e2000A~2500A: 4% ± 3dgt\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWire position: the tested wire is in the center of the jaw\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eData storage: 99 groups, displaying \"FULL\" symbol indicates that the storage is full\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eRS232 interface: RS232 interface is provided to upload stored data to the computer for data analysis\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCommunication line: RS232 communication line, 1.8m long\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFrequency: 50Hz, 60Hz automatic identification\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eGear shifting: fully automatic switching\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSampling rate: about 2 times\/second\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLine voltage: circuit test under AC 600V\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDisplay mode: 4-digit LCD digital display, length and width 47mmX28.5mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eInstrument size: 275mm long x 145mm wide x 40mm thick\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBacklight: Yes, light key control\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eData retention: data retention function: \"HOLD\" symbol display\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eOverflow display: over range overflow function: \"0L\" symbol display\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic shutdown: no operation for about 5 minutes after startup, and the backlight automatically turns off; There is no operation after about 15 minutes of startup, and the instrument automatically shuts down after 10 seconds of flashing to reduce battery consumption. Press any key to cancel flashing\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBattery voltage: When the battery voltage drops to about 5.2 V, the low battery voltage symbol will be displayed to remind you to replace the battery\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eInstrument weight: instrument: 830g (including battery)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWorking current: 50 mA for backlight; Backlight off 25mA\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eOperating temperature and humidity: - 10 ° C~40 ° C; Below 80% rh\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eStorage temperature and humidity: - 10C~60C; Below 70% rh\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eInsulation strength: AC 3700V\/rms (between iron core and shell)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eApplicable safety regulations: IEC1010-1, IEC1010-2-032, pollution level 2, CAT III (600V)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003c\/span\u003e\u003c\/div\u003e","brand":"mickcara","offers":[{"title":"000","offer_id":41178197557385,"sku":"00662-1","price":455.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0365\/2131\/2393\/products\/c5396491b9be28bc71e7f59713b6402d.png?v=1678433086","url":"https:\/\/mickcara.com\/products\/etcr7000b-large-caliber-clip-on-ammeter-0-0a-2500a-current","provider":"mickcara","version":"1.0","type":"link"}