{"product_id":"etcr8300-three-channel-leakage-current-monitoring-recorder-warmly-recommend","title":"ETCR8300 Three-Channel Leakage\/Current Monitoring Recorder Warmly recommend","description":"\u003cdiv\u003e\u003cspan\u003e\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Introductions：\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     ETCR8300 series Three-Channel Current\/Leakage Monitoring Recorder is well designed and manufactured for online measurement, monitoring and recording of Three-Channel AC leakage \/ current at the same time. It is composed of a tester, monitoring software, current clamp and communication cable, etc. This instrumenthas been widely applied the 380\/220 Power system. It can provide a safety and convenience measurement with accurate results.  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e          The instrument has a large LCD display with blue background and a large storage space. 3900 sets of data can be stored in the instrument. Three- channel current value can be display on the screen. In addition, the instrument can automatically store data at a interval, which is adjustable from 1 to 99 min.  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Monitoring software provides online and real-time monitoring and historical data inquiry. With the software developed by our technical department, the users can read, inquire, store, generate and print a fitting curve and report.  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e          The current clamp is made of a special alloy, adopts the latest CT technique and magnetic shielding technique and is not almost interfered by external magnetic field. This ensures high accuracy, high stability and high reliability of the values which are measured continuously  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Technical Specification：  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                           Functions      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Measuring AC leakage current and AC current of three channel, monitoring current in real-time manner, locating insulation faults and repairing electrical lines.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Power source      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     DC6V, alkaline battery LR03 1.5V×4\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Testing Method      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Split core type CT, true RMS\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Range      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     0mA-200A\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Resolution      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     1mA\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Accuracy      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     ±2%±5dgt\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Clamp size      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     35mm×40mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Instrument Dimension      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Tester(L×W×H): 75mm ×170mm ×30mm      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Current clamp(L×W×H): 122mm ×70mm ×33mm      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Mass      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Tester: 750g (battery included)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Current clamp: 170g × 3 PCS      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          LCD Dimension      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Display field: 44mm×27mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Shield Type      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Type B: Double shielding\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Sampling Rate      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     2 samples\/s\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Data storage      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     3900 sets (data loss does not occur after power failure or replacing the battery)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Time Setting      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Recording internal adjustable from 1 to 60 min, If set to 0 min, the auto-store function is turned off\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Recording Time      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Continuously operate for about 10 days at the power-saving mode\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Line Voltage      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Line with a voltage up to AC600V\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Overflow Display      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     The “OL” symbol is displayed when a measured value is beyond the measurement range\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Battery. Voltage      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     A Low-Battery symbol is displayed and the user should replace the battery with a new one when the battery voltage drops to 4.6V to 4.8V. In this case, the measured values are still accurate. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Rated Power      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     about 5mA at the power-saving mode, maximum current consumption: 20mA\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Lead Length      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     2 m\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Temperature and Humidity      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Working: -20C-50;below 80%rh\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Storage: -20c-50C;below 70%rh\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Insulation Resistance      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Higher than 100MΩ, 1000V\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Safety Codes      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     IEC1010-1, IEC1010-2-032, Pollution Class 2, CAT 3(600V), IEC61326(EMC standard)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Accessories      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Tester: 1 PCS, Current clamp: 3PCS, Instrument bag: 1 PCS, RS232 Com-cable:1 PCS; Software Disk: 1 PCS\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e        \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003c\/span\u003e\u003c\/div\u003e","brand":"mickcara","offers":[{"title":"ETCR8300","offer_id":41382249857161,"sku":"03109-1","price":777.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0365\/2131\/2393\/files\/20f8386d72a57129524d8538709d4535.jpg?v=1694853802","url":"https:\/\/mickcara.com\/products\/etcr8300-three-channel-leakage-current-monitoring-recorder-warmly-recommend","provider":"mickcara","version":"1.0","type":"link"}