{"product_id":"etcr9100-online-ac-current-monitor-high-low-voltage-ac-leakage-current-clamp-meter-with-digital-ammeter","title":"ETCR9100 Online AC Current Monitor High\/Low Voltage AC Leakage Current Clamp Meter With Digital Ammeter","description":"\u003cdiv\u003e\u003cspan\u003e\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e1.Features:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eETCR9100 Series H\/L Voltage CLAMP LEAKER has broken through the traditional structure, which is specially well-designed for measuring high voltage current, adopting the latest CT technology and integrated mask digital technology, formed by composition of a special use clamp leaker with a high-voltage insulation rod, as to ETCR9100B type --- wireless transmission of test data, it is equipped with wireless receivers, which can receive measured data within 30 meters line. If not using an insulation rod, it can be also used as a high precision low-voltage clamp leaker, or an alternating current meter, which can accurately measure 0.01mA of current or leakage current.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e ETCR9100 Series H\/L Voltage Clamp Leaker has an innovative integrated design between transducer clamp and transducer domain, ensuring the high-precision, high-reliability, and high-stability on constant test perennially. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e ETCR9100 Series H\/L Voltage Clamp Leaker is connected with insulation rod, which can be used for measuring high voltage current that is below 69KV, on-line current measurement, also having peak maintenance, data preservation, data storage, wireless transmission and other functions, and its special Clamp Leaker can make it easier for clamping or evacuating the tested wire through pressing or pulling back the insulation rod, time-saving and fast, widely used in transformer substation, power plant, industrial and mining enterprises as well as the inspection station and electrician maintenance departments for electrical current detection and field electrical operations. It can also replace the H\/L voltage transforming ratio tester, that is, to detect the high and low current for primary circuit and secondary circuit separately, and then calculate to conclude the change of high and low pressure. The insulation rod is light and convenient, with the advantages of anti-moisture, high temperature resistance, anti-impact, bending resistance, high insulation, flexibility and other characteristics.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e 2.Specifications:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Function\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    High voltage AC current measurement, low voltage AC current, current leakage measurement, online AC current measurement \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Power Supply\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   DC6V alkaline LR03×4)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Test Mode\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Clamp CT, integral approach\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e        Display Mode\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   4 bit LCD display, with backlight function\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       LCD Dimension\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   47mm×28.5mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Meter Dimension\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   LWH: 68mm×245mm×40mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Clamp Dimension\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   33mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Sampling Rate\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   2 times\/second\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Measurement Scope\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   0.00mA~600A (50\/60Hz automatic)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Resolution\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   0.01mA\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Shift\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   0.00mA~600A automatic shift\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                Accuracy    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         (23℃±5℃, below 70%RH)    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   0.00mA~100.0A:      ±1%±5dgt \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       100.0A~600.0A:      ±2%±5dgt\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Line Voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Below 60KV line test (with 5 insulation rods operation)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Data Memory\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   99 sets, memory process is shown by MEM , full storage is shown by blinking  FULL\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       PEAK value maintaining\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Automatically maintain the high test value, in usual testing mode, press key HOLD till the lighting of PEAK, that is, start PEAK to maintain this function. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Data Hold\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   In usual testing mode, press HOLD key to keep data, shown by “HOLD”\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Data Access\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    “MR” indication, can access to all data\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Overflow Display\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Over-range overflow function: shown in “OL  A”\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Automatic Shutdown\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   15 minutes after boot\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Battery Voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   When battery voltage is lower than 4.8V, battery voltage is shown in low symbol to remind battery replacement\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Meter Weight\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Detector: 335g (with battery), the total mass of meter: 2.5kg (including insulation rod and battery)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Working Temperature and Humidity\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   -25℃~40℃; below 80%Rh\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Storage Temperature and Humidity\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   -10℃~60℃; below 70%Rh\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Insulation Rod Dimension\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   φ32mm, 1m\/piece (5pieces)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Insulation Strength\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   AC 100kV\/rms (between the 5th insulation rod and high voltage current clamp core)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Structure\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Anti-drip type Ⅱ\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Safety Provisions\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   IEC1010-1, IEC1010-2-032, Pollution Class 2, CAT Ⅲ(600V), IEC61326(EMC standard)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Accessories\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Clamp Meter : 1 piece; meter box: 1 piece; insulation rod (1m): 5 pieces; battery (alkaline battery AAA): 4 pieces(not included package)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003c\/span\u003e\u003c\/div\u003e","brand":"mickcara","offers":[{"title":"000","offer_id":41382255034505,"sku":"03100-1","price":877.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0365\/2131\/2393\/files\/b0d4c5913f0fa7615811bcbb0e6177b2.jpg?v=1694854175","url":"https:\/\/mickcara.com\/products\/etcr9100-online-ac-current-monitor-high-low-voltage-ac-leakage-current-clamp-meter-with-digital-ammeter","provider":"mickcara","version":"1.0","type":"link"}