{"product_id":"etcr9100c-zinc-oxide-arrester-electric-leakage-detector","title":"ETCR9100C Zinc Oxide Arrester Electric Leakage Detector","description":"\u003cdiv\u003e\u003cspan\u003e\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e        \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     ETCR9100C Zinc Oxide Arrester Leakage Tester has unique features of automatic plug function, specially designed and manufactured for high voltage current measurement; use the latest CT technology and integrated mask digital technology; composed of special high voltage detector, wireless receiver and high voltage insulation rods. Wireless transmission can receive the measured data by penetrating storey building barriers or 30 meters. If not use insulated rods, it can also used as high-precision low-voltage clamp meter and leakage current meter, can accurately measure the 0.1mA ~1000A current or leakage current. The integrated design of clamp and lead zone of ETCR9100C Zinc Oxide Arrester Leakage Testerensures uninterrupted year-round high precision, high reliability and high stability test.  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e        \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     In general cases, the leakage current of Zinc Oxide Arrester should be less than 500uA. In a running power transmission line, if the leakage current of Zinc Oxide Arrester is higher than 500uA, than the parameter of Zinc Oxide Arrester is un-normal, which can be caused by besmirch, or internal damp, or aging. The bigger the leakage current, the arrester is more un-normal. The leakage current to be a importance reference to the maintenance department to find the power transmission problem, or to check whether an  arrester should be unstalled to under testing in lab or replace, avoid unnecessary replacement.  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e        \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         Technical Specifications   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e           \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                 Function       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      High precision and resolution measurement of leakage of Zinc Oxide Arresters\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                Power Supply       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      DC6V Alkaline LR03×8\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Test Mode       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Clamp CT, integral approach\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Transmission Mode       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Wireless transmission, the maximum distance of straight line transmission is about 30m\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Display Mode       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      4 bit LCD display, with backlight function\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               LCD Dimension       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      47mm×28.5mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                Meter Dimension       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      HV detector: 68mm×245mm×40mm; Receiver: 75mm×170mm×30mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Clamp Dimension       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      33mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Sampling Rate       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      2 times\/second\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Measurement Scope       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      AC 0.000mA-30.00mA(50\/60Hz Automatic identification)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Resolution       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      1uA\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Shift       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Full automatic shift\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Accuracy       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      ±2%±5dgt (23C±5C, Below 80%RH)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Data Memory       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     99 sets, memory process is shown by MEM , full storage is shown by blinkingFULL       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               PEAK value maintaining       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Automatically maintain the high test value, in usual testing mode, press keyHOLD till the lighting of PEAK, that is, start PEAK to maintain this function. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Data Hold       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      In usual testing mode, press HOLD key to keep data, shown by “HOLD”\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Data Access       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       “MR” indication, can access to all data\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Overflow Display       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Over-range overflow function: shown in “OL A”\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               No Signal Indication       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       “no- -” is shown when receiver does not receive the dynamic display of signal transmission\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Automatic Shutdown       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      15 minutes after boot\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Battery Voltage       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      When battery voltage is lower than 4.8V, battery voltage is shown in low symbol to remind battery replacement\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Meter mass       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Detector: 335g (with battery), the total mass of meter: 2.5kg (including insulation rod and battery)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Working Temperature and Humidity       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      -25C-40C; below 80%Rh\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Storage Temperature and Humidity       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      -10C-60C; below 70%Rh\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Insulation Rod Dimension       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      φ32mm, 1m\/piece (5pieces)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Insulation Strength       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      AC 100kV\/rms (between the 5th insulation rod and high voltage current clamp core)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Structure       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Anti-drip type II\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                               Accessories       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Clamp: 1 piece; receiver: 1 piece; meter box: 1 piece; insulation rod (1m): 5 pieces; battery (alkaline battery AAA): 8 pieces(not included package)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003c\/span\u003e\u003c\/div\u003e","brand":"mickcara","offers":[{"title":"000","offer_id":41382255493257,"sku":"03021-1","price":1322.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0365\/2131\/2393\/files\/61d0e0a4961ced638ab68b33cf8b34e5.jpg?v=1694854203","url":"https:\/\/mickcara.com\/products\/etcr9100c-zinc-oxide-arrester-electric-leakage-detector","provider":"mickcara","version":"1.0","type":"link"}