{"product_id":"etcr9200b-wireless-h-l-voltage-clamp-current-meter","title":"ETCR9200B Wireless H\/L Voltage Clamp Current Meter","description":"\u003cdiv\u003e\u003cspan\u003e\u003cp\u003e\u003cspan\u003eireless H\/L Voltage Clamp Current Meter\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   ETCR9200B Wireless H\/L Voltage Clamp Current Meter has broken through the traditional structure, which is specially well-designed for measuring high voltage current, adopt latest CT technology and integrated mask digital technology, composed of special clamp current meter， wireless receiver and high voltage insulation rods. Wireless transmission can receive measured data within 30 meters line. Without insulation rods, it can used as high-precision low-voltage clamp meter and leakage current meter , can accurately measure the current or leakage current of 0.01mA.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eETCR9200B Wireless H\/L Voltage Clamp Current Meter adopt hook type structure of innovation, which can hook the line to test, and through wireless transmission test date can save the physical power of user, to ensure the high precision , high stability and high reliability of perennial uninterrupted measurement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe rods of ETCR9200 B Wireless H\/L Voltage Clamp Current Meter can be used for insulating sheath wires(≤60kV ) and bare wire t (≤35kV) high voltage line current measurement and online current measure below 60kV,also with the factions of peak value holding, data holding, data storage and wireless transmission , etc. It is easy to clamp or disconnect the wire by pulling-down or forwarding the insulation rods of the special clamp current meter, with the advantages of safely and time-saving. Widely used in power plant, substation industrial and mining enterprise, inspection station, electrician maintenance department for current sensing and field working. t can also be used as high and low voltage changing ratio tester , that is, respectively test the first loop and secondary loop high and low voltage change through manually calculation . The insulation rod is light and convenient, with the advantages of anti-moisture , high temperature resistance, anti-impact , bending resistance , high insulation , flexibility and other characteristics.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Technical Specification  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e        \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                           Function      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  H-voltage AC current measure,L-voltage AC \/leakage current measure，      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             AC current monitor online      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Power Supply      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     DC6V Alkaline Dry Battery(1.5V AAA × 4)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Test Method      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Clamp CT, Integral Method；；hook the meter on the line to test，save the physical power of user。\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Transmission method      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     wireless transmission, the maximum distance for direct transmission is about 30m.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Clamp Diameter      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     φ68mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Range of measurement      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     0.00mA～1000A(50Hz\/60Hz Automatic\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Resolution      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     0.01mA\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Shift      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     0.00mA～1000A Automatic Shift\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Test Accuracy (23℃±5℃，≤80%RH)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     0.00mA～299mA: ±1%±3dgt \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             0.30A～49.9A: ±1.5%±5dgt \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             50.0A～199.9A: ±2%±5dgt\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             200A～600A:    ±3%±5dgt   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             601A～1000A:   ±4%±5dgt  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Display Mode      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     4 digital LCD display\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          LCD Dimension      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Tester: LCD: 35mm×21.5mm receiver LCD: 47mm×28.5mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Meter Dimension      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Tester: 218mm×135mm×60mm receiver:170mm×75mm×30mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Sampling Speed      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     About 2 times\/second\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Data Storage      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     99 Groups； during storage, the symbol “MEM” gives indication, “FULL” mark will flash to indicate the memory has been full.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          PEAk Maintenance      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Automatically maintain the height of the test value，usually in the test mode press PEAK,LCD top right corner will display “PE”,that is, to keep open the PEAK function, then press PEAK key to cancel this function key      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Circuit Voltage      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Test insulating sheath wires（≤60kV）and bare wire t（≤35kV）(operated with insulation rod)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Data Preservation      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Under general test mode, press HOLD button to preserve data, “DH” symbol display. then press HOLD Key to cancel this function\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Data Access      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     “MR” symbol indicates, it can read the stored data by turning upwards and downwards.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Overflow Display      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Exceed measurement range overflow function: “OL A” symbol display\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Auto Shut Down      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     About 15 minutes after booting, the meter will shut down automatically, in order to decrease the battery consumption.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Battery Voltage      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     When the battery voltage is below 4.8V, the symbol of battery voltage“    ”will show to remind to replace battery.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Weight      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Tester: About 620g (Including battery)  receiver: about 220g(Including battery)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Total quality of meter: about 2.5kg(including insulation rod and battery)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Work Temperature and Humidity      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     -10℃～40℃; ≤80%Rh\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Storage Temperature and Humidity      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     -10℃～60℃;≤70%Rh\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          interference      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     No same frequency interference of 315MHz and 433MHz\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Insulated Rod Dimension      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     φ32mm,1m\/ Section（5 Sections）\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Insulation Intension      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  Tester: AC 2kV\/rms(Between core and shell)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Insulation rod: AC 100kV\/rms(5 sections insulating rod all connections, between both ends)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          Structure      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Anti-Dripping Type II\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          accessories      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Tester: 1set; receiver:1pcs;  meter box:1pcs; Insulation rod(1m): 5 Sections.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e        \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003c\/span\u003e\u003c\/div\u003e","brand":"mickcara","offers":[{"title":"ETCR9200B","offer_id":41382145720457,"sku":"02960-1","price":1455.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0365\/2131\/2393\/files\/2c5e7bb00ac7f69723d5da4162a9f56a.jpg?v=1694834397","url":"https:\/\/mickcara.com\/products\/etcr9200b-wireless-h-l-voltage-clamp-current-meter","provider":"mickcara","version":"1.0","type":"link"}