Skip to product information
1 of 5

mickcara

HANTEK DSO8072E Oscilloscope High Bandwidth 70MHz-200MHz Oscilloscope 1GS/s Sample Rate 2M Memory Depth

HANTEK DSO8072E Oscilloscope High Bandwidth 70MHz-200MHz Oscilloscope 1GS/s Sample Rate 2M Memory Depth

Regular price $999.00 USD
Regular price Sale price $999.00 USD
Sale Sold out
Shipping calculated at checkout.
Color




HANTEK DSO8072E Oscilloscope High Bandwidth 70MHz-200MHz Oscilloscope 1GS/s 


Sample Rate 2M Memory Depth

  

 DSO8000E Series:

 Oscilloscope/Recorder/DMM/Spectrum Analyzer/Frequency Counter/Generator.

 High Bandwidth 70MHz-200MHz Oscilloscope

 1GS/s sample rate,2M Memory Depth.

 6000 Counts DMM with analog bargraph.

 Advanced automatic measurements.

 IP-51 rated for dust and drip proof to withstand harsh environments


      Model

   DSO8072E

   DSO8102E

   DSO8152E

   DSO8202E

       Acquisition

       Sample Modes

   Real-Time Sample

       Acquisition Modes

   

       Normal

   Normal data only

       Peak Detect

   High-frequency and randon glith capture

       Average

   Wavefom Average, selectable 4,8,16,32,64,128

       Inputs

       Inputs Coupling

   AC, DC, GND

       Inputs Impendance

   1MΩ±2% 20pF±3pF

       Probe Attenuation

   1X, 10X

       Supported Probe Attenuation Factor

   1X, 10X, 100X, 1000X

       Maximum Input Voltage

   CAT I and CAT II: 300VRMS (10×), Installation Category;

CAT III: 150VRMS (1×)

       Horizontal System

       Sample Rate Range

   1GS/s

       Waveform Interpolation

   (sin x)/x

       Record Length

   2M

       SEC/DIV Range

   4ns/div~2000s/div, in a  2, 4, 8 sequence

   2ns/div~2000s/div, in a  2, 4, 8 sequence

       Sample Rate and

Delay Time Accuracy

   ±50ppm over any ≥1ms time interval

       Scanning Speed Range

   4ns/div to 8ns/div; (-8div x s/div) to 40ms;

20ns/div to 80μs/div;(-8div×s/div) to 40ms;

200μs/div to 40s/div;(-8div×s/div) to 400s;

   2ns/div to10ns/div;(-4div×s/div) to 20ms;

       Delta Time Measurement Accuracy

(Full Bandwidth)

   Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);

>16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);

Sample interval = s/div ÷ 200

       Vertical System

       Vertical Resolution

   8-bit resolution, all channel sampled simultaneously

       Volts Range

   2mV/div to 100V/div at input BNC

       Bandwidth

   70MHz

   100MHz

   150MHz

   200MHz

       Rise Time at BNC( typical)

   5ns

   3.5ns

   2.3ns

   1.8ns

       Analog Bandwidth in

Normal and Average

modes at BNC or with probe,

DC Coupled

   ±400V(100V/div-20V/div);

±50V(10V/div-5V/div);

±40V(2V/div-500mV/div);

±2V(200mV/div-50mV/div);

±400mV(20mV/div-2mV/div);

       Math

   +, -, *, /, FFT

       FFT

   Windows:  Hanning, Flatop, Rectamgular, Bartlett, Blackman; 1024 sample point

       Bandwidth Limit

   20MHz

       Low Frequency Response (-3db)

   ≤10Hz at BNC

       DC Gain Accuracy

   ±3% for Normal or Average acquisition mode, 100V/div to 10mV/div.

±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div.

       DC Measurement Accuracy,

Average Acquisition Mode

   Measurement Type: Average of ≥16 waveforms with vertical position at zero

Accuracy: ± (3% × reading + 0.1div + 1mV) when 10mV/div or greater is selected.

Measurement Type: Average of ≥16 waveforms with vertical position not at zero

Accuracy: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div].

       Volts Measurement Repeatability,

Average Acquisition Mode

   Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions

   

 Oscilloscope/Recorder/DMM/ Spectrum Analyzer/Frequency Counter/Arbtrary Waveform generator.

 High Bandwidth 70MHz-200MHz Oscilloscope, 1GS/s sample rate, and 6000 Counts DMM with analog bargraph.

 Advanced automatic measurements.

 IP-51 rated for dust and drip proof to withstand harsh environments

 2M Memory Depth.

 Large 5.6 inch TFT Color LCD Display; High Resolution(640*480); Dual-Window Design --More clear, More Detailed

 One-touch automatic setup optimizes the position, range, timebase, and triggering to assure a stable display of virtually any waveform.

 Easy-to-use pop-up menu with built-in multi-language help system.

 32 Automatic Measurements.

 Waveform Math: Add, Subtract, Multiply, and Divide.

 Store and recall over.

 Automatic cursor tracking measurements.

 XY Mode.

 Built-in FFT function converts a time-domain signal into its frequency components to measure harmonic content and distortion in systems.

 Waveform Recorder to capture/replay input waveforms from CH1 and CH2 with a maximum record length of 1000 frames.

 Pass/Fail function compares a stored waveform to an unknown input.

 Average Mode for smoothing waveforms.

 Square Wave Output (2V, 1kHz) for probe adjustment.

 USB Host/Device 2.0 full-speed interface; support removeable disk;  LAN Option, easy to control by PC or long-distance.

 Dimensions (mm): 260(L)x220(W)x75(H), be carried easily.


  