 Features:

 1. Applied to ultrasonic atomizer and other industrial control equipment

 2. The instrument selects the mode according to actual needs: humidification, dehumidification, time control function

 3. Equipped with a digital automatic control system, which can set the upper limit, return difference, and switch time

 Mode selection

 Humidification mode (P01)

 Enter mode settings

 Power on, long press the SET button, the controller enters the setting state, the nixie tube displays P01, press the SET button to save the data and enter the upper limit parameter setting

 Upper limit parameter setting

 The nixie tube displays the upper limit of humidity, press +-to modify the data, press SET to save the data and enter the lower limit parameter setting

 Lower limit parameter setting

 Dehumidification mode (P02)

 Enter mode settings

 Power on, long press the SET button, the controller enters the setting state, press +-to switch to P02, press the SET button to save the data and enter the upper limit parameter setting

 Upper limit parameter setting

 The nixie tube displays the upper limit of humidity, press +-to modify the data, press SET to save the data and enter the lower limit parameter setting

 Lower limit parameter setting

 The digital tube displays the lower limit of humidity. Press the +-key to modify the data, press the SET key to save the data and exit the setting state

 Time cycle mode (P03)

 Enter mode settings

 Power on, long press the SET button, the controller enters the setting state, press +-to switch to P03, press the SET button to save the data and enter the "on" parameter setting

 Boot time setting

 The digital tube displays the "on" time parameter, press the +-button to modify the data, press the SET button to save the data and enter the "stop" time setting

 Downtime setting

 The digital tube displays the "stop" time parameter, press +-key to modify the data, press the SET key to save the data and exit the setting state

 Controller job description

 Add humidity control:

 When the actual humidity is less than or equal to the lower limit of humidity, the humidifier starts to humidify

 When the actual humidity ≥ the upper limit of humidity, the humidifier stops working

 In addition to humidity control:

 When the actual humidity is less than or equal to the lower limit of humidity, the dehumidifier starts to dehumidify

 When the actual humidity ≥ the upper limit of humidity, the dehumidifier stops working

 Time cycle mode control:

 "On" time + "stop" time = cycle time

 For example: work 60s+stop 30s=90s cycle once

 

 


RETURNS POLICY

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

SHIPPING

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

How to choose the correct size:

Step 1 Please measure your foot length carefully.

Step 2 Please choose the correct size according to your foot length and chinese size.

For example, If your foot length is 255 mm , you should choose the size 8.

Step 3 If you\'re not sure of the correct size, you can click chat with us!

WHATSAPP:+8613625959351

Have Questions?Ask An Expert
Humidifier Parts Timed automatic switch socket with humidity sensor Industrial humidifier dehumidifier intelligent controller
You have successfully subscribed!