{"product_id":"ls126a-uv-aging-tester-radiometer-c-ultraviolet-light-meter","title":"LS126A UV Aging Tester Radiometer C Ultraviolet Light Meter","description":"\u003cdiv\u003e\u003cspan\u003e\u003cp\u003e\u003cspan\u003e              \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            LS126C Uv Aging Tester Radiometer Uvc Ultraviolet Light Meter UV Meter     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Overview    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             LS126C UV Light Meter (2nd)      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                        LS126C UV light meter is a professional instrument for measuring the intensity of UVC lamps, that is, the power of ultraviolet radiation energy per unit area. The UV radiometer is delivered with a 1-meter test hook. The LS126C UVC light meter also has a wireless data transmission function. After connecting with the mobile phone APP, it can monitor the intensity of the UVC lamp in real time from a certain distance to avoid UV burns during the test.         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                   uv aging testerradiometer uvcultraviolet light meter         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e        \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            Application    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                                              \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e          \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e          Parameters         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                                                     Parameters             \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                       LS126C UV Light Meter             \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                                             Spectral response             \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                       230nm-280nm, λp = 254nm             \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                                             Measuring range             \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                       0 - 20000 μW \/ cm²             \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                                             Resolution             \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                       0.1μW \/ cm²             \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                                             Measuring accuracy             \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                       ±10%             \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                                             Power value storage interval             \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                       1s\/10s\/60s optional             \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                                             Recording period             \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                       10 min \/ 100 min \/ 600 min             \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                                             Wireless transmission distance                         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                       50 meters (open space)             \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                                             Instrument size             \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                       148mm ×76mm ×26mm (L*W*H)             \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                                             Probe size             \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                       Diameter 39mm × thickness 15mm             \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                                             Probe wire length             \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                       1 meter             \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                                             Weight             \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                       About 300 g             \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                                             Display             \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                       240*160 dot matrix LCD             \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                                             Battery             \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                       4 AAA alkaline dry batteries             \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                              \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e        \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            Features    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                          1. The LS126C UV intensity tester is based on the detection requirements of 1 meter distance specified in the \" WST 367-2012 Regulation of disin fection technique in healthcare settings \" and a 1 meter test hook is provided.         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e        \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                                    2. The UVC light meter comes with a wireless data transmission function. After connecting a dedicated mobile phone APP, the data can be wirelessly monitored from a certain distance to avoid being burned by ultraviolet rays when viewing the data on site.         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                   3. LS126C UV irradiance meter has intelligent statistical data function, real-time statistics of real-time power value, maximum value, minimum value, average value in measurement data, measurement duration and test date.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe real-time clock function can be used to trace the test date of historical data.         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                             \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e        \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                                  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                           4. The UV light meter can be set to automatically shut down within 0-10 minutes. The test data will be automatically saved when the instrument is turned off, enabling unattended measurement. The NO.1 data displayed on the screen when the machine is turned on is the latest test data. The instrument can record a total of 25 sets of data.        \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                          \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                                  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                                    5. The UV radiometer uses high-precision UVC filters and professional UV sensors to eliminate the influence of light intensity in the UVA and UVB bands on the data. As shown below.         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                   6. Using advanced digital probe technology, digital signal processing is done directly on the probe, the probe is not susceptible to interference and provides excellent test accuracy.         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                   7. LS126C UV intensity detector is equipped with USB communication port and dedicated PC software. The test data can be exported to the EXCEL by computer software. The test report can also be generated and printed.         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                   uv aging testerradiometer uvcultraviolet light meter         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e        \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                                  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                                    8. When the instrument is off, long press the power button to enter into the parameter setting mode. For detailed steps, please refer to the picture below.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e(1) Set whether auto power off is required\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e(2)Setting the data storage interval or auto power off time\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e(3) Set whether to display the date \/ time\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e(4) Setting the date \/ time         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e        \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                                  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQualification and Standards    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                         1. \" WST 367-2012 Regulation of disin fection technique in healthcare settings \" A.3 Monitoring of the Effect of Ultraviolet      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                     (1) UV light meter measurement method\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAfter turning on the UV lamp for 5min, place the UV light meter probe with a measuring wavelength of 253.7nm at the center of 1m\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003evertical distance under the tested UV lamp. The special UV lamp is measured at the recommended distance. After the meter is\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003estable, the displayed value is the irradiance value of the ultraviolet lamp.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e(2) Judgment of results\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor ordinary 30W straight tube UV lamps, the irradiation intensity of the new lamp should meet the requirements of GB 19258; the\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003euse of ultraviolet lamp irradiation intensity ≥70μW \/ cm² is qualified; the 30W high-intensity ultraviolet lamp irradiation\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eintensity ≥180μW \/ cm² is qualified.       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                        2. LS126C UV light meter meets national standards        \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                 JJG 879-2015 Verification Regulation of Ultraviolet Radiometers        \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e              \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                                  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e            \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eParamenters    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                                  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                                    Parameters         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                           LS126C UV Light Meter         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                         Spectral response         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                           230nm-280nm, λp = 254nm         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                         Measuring range         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                           0 - 20000 μW \/ cm²         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                         Resolution         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                           0.1μW \/ cm²         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                         Measuring accuracy         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                           ±10%         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                         Power value storage interval         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                           1s\/10s\/60s optional         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                         Recording period         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                           10 min \/ 100 min \/ 600 min         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                         Wireless transmission distance                         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                           50 meters (open space)         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                         Instrument size         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                           148mm ×76mm ×26mm (L*W*H)         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                         Probe size         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                           Diameter 39mm × thickness 15mm         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                         Probe wire length         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                           1 meter         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                         Weight         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                           About 300 g         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                         Display         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                           240*160 dot matrix LCD         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                                         Battery         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                           4 AAA alkaline dry batteries         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                 \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e              \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003c\/span\u003e\u003c\/div\u003e","brand":"mickcara","offers":[{"title":"LS126C","offer_id":41163984830601,"sku":"01118-1","price":1088.0,"currency_code":"USD","in_stock":true},{"title":"LS126A","offer_id":41163984863369,"sku":"01118-2","price":1088.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0365\/2131\/2393\/products\/c07188dbda580973bff20fc76b131b55.jpg?v=1677571199","url":"https:\/\/mickcara.com\/products\/ls126a-uv-aging-tester-radiometer-c-ultraviolet-light-meter","provider":"mickcara","version":"1.0","type":"link"}