First, the product name:

Anti-decubitus mattress


Second, the scope of application:

This product is suitable for bedridden patients, to prevent patients from acne due to long-term bed.


Third, the product structure consists of:

This product is composed of inflatable cushion and air pump. The inflatable cushion is made of high frequency heat-sealable PVC cloth. It has a spherical air chamber. The air pump is connected to the inflatable cushion through joints, air pipes, air inlets, etc. Inflate the air chamber.


V. Working principle:

Through the inflator pump, the odd and even air chambers of the inflatable cushion are alternately filled and deflated, so that the patient's body bed part is in intermittent contact with the cushion surface to achieve an anti-acne effect. When the inflation pressure reaches 3 kPa, the cushioned micro-jet holes are evenly distributed. Emissions of gases outside the body improve air circulation under the body of the patient and enhance anti-acne effects.


Sixth, the main technical indicators:

1, when filling and deflation: single pump air pump inflation 5min ± 5%, deflation 5min ± 5%, dual pump air pump 9min ± 5%, deflation 9min ± 5%;

2. Inflatable air pressure: 12kPa ± 0.5kPa (can be adjusted between 0 and maximum air pressure);

3, the most weight bearing: 120kg;

4, working noise: <60dB

5, continuous working time: >24h

6. Inflatable pump power consumption: <20VA


VII. Working conditions:

1, bad environment temperature: 5-40 °C;

2. Relative humidity: <85%

3, power conditions: 220V ± 22V, 50hz


Eight, use method:

1. Place the air mattress on the sickbed or single bed (the surface of the bed surface cannot be pointed or hard to prevent the air cushion from being damaged) so that the air intake hole is located on the patient's foot;

2. Take the air pump out of the foam box, according to the situation, it can be placed on the desktop or under the bed with a solid position more than 20cm above the ground, and the use environment should be clean and dry;

3. Turn on the air pump power, turn on the power switch, and turn the pressure adjusting knob clockwise to the maximum state. The air outlet of the air pump has gas discharge, which is suitable for single pump air pump;

4. Connect one end of the airway tube to the air nozzle on the mattress, and connect the other end to the air outlet on the right side of the air pump. The connection should be firmly in place and no air leakage can occur.

5. The air mattress enters into the inflation work state. After inflating for 15-20 minutes, the pressure in the air bed can reach the normal state of use. If necessary, a bed sheet can be laid on the air mattress and the patient can be moved to the air cushion according to the needs of the patient. Adjust the air pump pressure adjustment knob to change the softness of the air heat;

6. Unfasten the snaps on both sides when you are in urine and excretion, and open the small air cushion at the hole. Then you can use it conveniently. Then return to the original position to restore the fluctuating state.

7, according to the needs of the patient can be used for 24 hours continuous inflation, or use as directed


Nine, contraindications:

Anti-decubitus gas bed has a thermal fluctuation function, the fracture surgery can not use this product.


Tenth, safety precautions:

1. If abnormal operation of the air pump (such as loud noise, odor, etc.) is found during use, cut off the power immediately and stop using it.

2. Patients with a resting weight exceeding 120KG cannot use this mattress.

3. The mattress cannot be used by patients who do not heal the surgical incision.

4, in the use of the process should avoid contact with sharp hard objects, so as not to scratch the mattress.

5. Care should be taken to keep the mattress clean, and often use neutral detergents to avoid contact with contaminants.

6. In case of failure during use, the air mattress should be repaired by a trained professional to notify the manufacturer of maintenance.

7. When not in use, the gas in the mat should be drained, folded into the original crates, stored in a dry, well-ventilated, ambient temperature -20°- + 55°C, relative humidity not exceeding 90%, non-corrosive substances Indoors, and into strong sunlight.

8. This product should be used under the guidance of a doctor.


Eleven, quality assurance instructions:

1, Within six months of purchasing this product,

2. For products that last more than half a year, the company shall be responsible for free maintenance. Only freight and accessories fees will be charged for maintenance.

3. Damage caused by improper use or due to improper storage is not within the scope of service.

4. If you find the quality problem of this product, please contact us as soon as possible so as to serve you in time.

Twelve, storage method:


When using, keep it clear, store it in a dry and ventilated place, pay attention to moisture.


RETURNS POLICY

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

SHIPPING

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

How to choose the correct size:

Step 1 Please measure your foot length carefully.

Step 2 Please choose the correct size according to your foot length and chinese size.

For example, If your foot length is 255 mm , you should choose the size 8.

Step 3 If you\'re not sure of the correct size, you can click chat with us!

WHATSAPP:+8613625959351

Have Questions?Ask An Expert
Medical Hospital Sick Bed Alternating Pressure Air Mattress with Pump Prevent Bedsores and Decubitus Pneumatic Massage Cushion
You have successfully subscribed!