{"product_id":"testo-770-2-clamp-meter-0590-7702-auto-ac-dc-and-large-two-line-display","title":"Testo 770-2 Clamp Meter 0590 7702 Auto AC\/DC and Large Two-line Display","description":"\u003cdiv\u003e\u003cspan\u003e\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTesto 770-2 Clamp Meter 0590 7702 Auto AC\/DC and Large Two-line Display\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Product Description\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  The testo 770-2 clamp meter makes it so much easier to work on tight measuring points, such as switching cabinets. The clamp meter's movable pincer arm can be fully retracted into the instrument. This means you can accurately grab tightly packed conductors such as cables and check them for faults.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFurthermore, it enables measurement of the starting current on electric motors and ionisation current testing in the µA range. The supplied temperature adapter for thermocouple probes can be used to measure electrical parameters as well as temperatures (compatible type K thermocouple probe can be ordered separately).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe clamp meter detects and selects AC\/DC fully automatically and also provides automated selection of other electrical parameters such as resistance, continuity, diode and capacitance. This makes operation easier and more reliable than ever before. Your readings are clearly and distinctly presented on the two-line display.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e              Temperature - TC Type K (NiCr-Ni)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                   Measuring range\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     -20 to +500 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Accuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     ±1 °C (0 to +100 °C)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Resolution\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     0.2 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                            DC voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                   Measuring range\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     1.0 to 600.0 V\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Resolution\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     max. 1 mV\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Accuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     ± (0.8 % of mv + 3 Digit)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                            AC voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                   Measuring range\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     1.0 mV to 600.0 V\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Resolution\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     max. 1 mV\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Accuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     ± (1.0 % of mv + 3 Digit)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                            DC current\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                   Measuring range\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     0.1 to 400.0 A (clamp)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e0.1 to 400.0 μA (measuring cables)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Resolution\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     0.1 (clamp)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e0.1 (measuring cables)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Accuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     ± (2 % of mv + 5 Digit) (clamp)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e± (1.5 % of mv + 5 ) (measuring cables)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                            AC current\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                   Measuring range\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     0.1 to 400.0 A (clamp)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e0.1 to 400 μA (measuring cables)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Resolution\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     0.1 A (clamp)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e0.1 μA (measuring cables)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Accuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     ± (2 % of mv + 5 Digit) (clamp)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e± (1.5 % of mv + 5 Digit) (measuring cables)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                            Resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                   Resolution\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     max. 0.1 Ohm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Measuring range\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     0.1 to 40.00 MOhm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Accuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     ± (1.5 % of mv + 3 Digit)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                            Capacitance\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                   Resolution\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     max. 0.01 nF\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Measuring range\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     10 nF to 100.0 μF\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Accuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     ± (1.5 % of mv + 5 Digit)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                            General technical data\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                   Operating humidity\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     0 to 80 %RH\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Weight\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     378 g\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Dimensions\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     249 x 96 x 43 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Operating temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     -10 to +50 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Product colour\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     Black\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Connectable probes\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     1 x temperature probe (adapter required for type K thermocouples)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Standards\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     EN 61326-1; EN 61010-2-032; EN 61140\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Battery type\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     3 AAA micro batteries(not included package)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Display type\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     LCD (Liquid Crystal Display)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Display size\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     2 lines\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Interface\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     2 measuring jacks\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Storage temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     -15 to +60 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Overvoltage Category\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     CAT IV 600V; CAT III 1000V\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Authorizations\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     CSA; CE\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Internal_resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     11 MOhm (AC \/ DC)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                            Instrument Measurement Functions\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                   Diode test\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     yes\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Continuity testing\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     yes\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Display ligthing\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     yes\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Hold\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     yes\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             MinMax\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     yes\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Temperature measurement with adapter\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     yes\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             True RMS\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     yes\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Inrush current measurement\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     yes\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Display (counts)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     4,000\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             μA current measuring range\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     yes\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e             Autom. measurement parameter detection\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     yes\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003c\/span\u003e\u003c\/div\u003e","brand":"mickcara","offers":[{"title":"Testo 770-2","offer_id":41383211106441,"sku":"03177-1","price":322.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0365\/2131\/2393\/files\/49d27bf56d2c1917eef7ca6c837bb113.jpg?v=1694934052","url":"https:\/\/mickcara.com\/products\/testo-770-2-clamp-meter-0590-7702-auto-ac-dc-and-large-two-line-display","provider":"mickcara","version":"1.0","type":"link"}