{"product_id":"tuf-2000b-tm-1-ultrasonic-liquid-flow-meter-with-tm-1dn50-700mm-transducer-wall-mounted-type-flowmeters","title":"TUF-2000B-TM-1 Ultrasonic Liquid Flow Meter with TM-1(DN50-700mm) Transducer Wall-Mounted Type Flowmeters","description":"\u003cdiv\u003e\u003cspan\u003e\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTUF-2000B-TM-1 Ultrasonic Liquid Flow Meter with TM-1(DN50-700mm) Transducer Wall-Mounted Type Flowmeters\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eNOTE: Usually we do not ship the liquid ultrasonic Transducer Coupling Agent because of air traffic control, if you have special requirements on gel, please tell us.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIntroduction of Ultrasonic flow meter:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTUF-2000B Flowmeter can be virtually applied to a wide range of long-term online measurement. Convertor protection class IP67,transducer protection class IP98.A variety of liquid applications can be accommodated: ultra-pure liquids ,portable water,chemicals,raw sweage,reclaimed watere,cooling water,river water,plant.etc\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePerformance and Parameter:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e      Items\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Performance \u0026amp;amp;Parameter\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eConvertor\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e         \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Principle\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Transit-time ultrasonic flowmeter\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Accuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   ±1%\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Display\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   2x20 character LCD with backlight, support the language of Chinese, English, Italy, Turkish\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Signal output\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   1way 4-20mA output, electric resistance 0-1K, accuracy0.1%\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       1 way OCT pulse output(Pulse width-1000ms, default is 200ms))\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       1 way Relay output\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Signal input\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   3 way 4-20mA input, accuracy 0.1%, acquisition signal such as temperature, press and liquid level\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Connect the temperature transducer P100, can finish the heat\/energy measurement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Data Interface\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Insulate Rs485 serial interface, upgrade the flowmeter software by computer, support the MODBUS.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Special Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Twisted-pair cable, generally, the length under 50 meters, select the Rs485, transmission distance can over 1000m\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePipe Installation Condition\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Pipe material\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Steel, stainless steel, cast iron, copper, cement pipe, PVC, Aluminum, glass steel product, liner is allowed\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Pipe diameter\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   25-6000mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Straight pipe\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Transducer installation should be satisfied: upstream10D, downstream5D, 30D from the pump.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e                \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMeasuring Medium\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Type of liquid\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Single liquid can transmit sound wave; such as water (hot water ,chilled water, city water, sea water, waste water, etc); sewage with small particle con tent, oil(curde oil, lubricating oil, diesel oil, fuel oil, etc); chemicals(alcohol, etc); plant effluent; beverage; Ultra-pure liquids, etc\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   -30-160℃\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Turbidity\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   No more than 10000ppm and less bubble\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Flow rate\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   0-±7m\/s\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Convertor; -20-60℃; Flow Transducer: -30-160℃\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Humidity\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Convertor: 855RH; Flow Transducer: can measure under water, water depth≤2m\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Working Environment\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Convertor; -20-60℃; Flow Transducer: -30-160℃\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Humidity\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   Convertor: 855RH; Flow Transducer: can measure under water, water depth≤2m\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Power Supply\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   DC8-36V or AC85-264V(Optional)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Power Consumption\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   1.5W\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e       Dimension\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   132*150*85mm(convertor)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e Standard Packing:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e TUF-2000B Host\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e Steel Belt\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e TM-1 Ultrasonic Transducer\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e2 x 5m Flow Signal CableOptional Transducers\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003c\/span\u003e\u003c\/div\u003e","brand":"mickcara","offers":[{"title":"TUF-2000B-TM-1","offer_id":41380375658633,"sku":"02827-1","price":888.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0365\/2131\/2393\/files\/c8cb30b91e66b6972931549fc8d2aa55.jpg?v=1694748064","url":"https:\/\/mickcara.com\/products\/tuf-2000b-tm-1-ultrasonic-liquid-flow-meter-with-tm-1dn50-700mm-transducer-wall-mounted-type-flowmeters","provider":"mickcara","version":"1.0","type":"link"}