AC220V
DC12V
$99.00
customers are viewing this product
Tags:

   The default version A is: powered by AC220V ( available from 210V to 240V ). If your country is 110V, no 220V, you can choose Version B: DC12V

  Instruction:

  It is a KONLEN WIFI intelligent water level controller, which can be set by APP to realize water level monitoring, Water supplement or drainage, high and low water level remote APP push alarm notification etc,.

  The product is suitable for various water level control occasions, such as HVAC system, hot water process, municipal drainage, boiler, water tower, storage tank, breeding irrigation etc.

  Main Features:

  1. Real-Time Supervision: APP can display the current water level,

  2. Turn on/off equipment (relay 1) remotely via App. Users can also control it on/off by manual switch button B.

  3. Two relay outputs: Relay 1 control water level, Relay 2 for Anti water dry heating protection.

  4. Preset"Add water" or "Pump water" working mode, can auto turn on/off relay 1 when it reaches to the preset water level value.

  5. Set upper and Lower limit value of water level alarm via APP, real-time push alarm notification to users' smartphone.

  6. Can set relay 1 running or delay working time.

  A: WIFI configuration button

  B: On/Off Switch of Relay Output 1: Users can press the button B to switch on/off Relay 1 manually.

  The manual switch B is only effective when the current water level is between the preset start and stop- water level value.

  C: WIFI Configuration Indicator/ Relay Output 1 Status Indicator

  D: Relay Output 2 Status Indicator

  Remark:

  Terminal 1: No use.

  Terminal 2: 100% water level

  Terminal 3: 75% water level

  Terminal 4: 50% water level

  Terminal 5: 25% water level

  Terminal 6: Public water point (COM)

  Terminal 7,8: Relay Output 1 (Normal Open)

  Terminal 9,10: Relay Output 2 (Normal Open)

  Terminal 11,12: AC220V Power Supply.

  Note:  If your country is 110V, no 220V, please choose Version B: DC12V.

  Wiring Connection (Take" add water" as example)

  Water level rising: water level <; 25% electrode; App display 0%; reach to 25%, App display 25%; reach to 50% , App display 50%; reach to 100%, App display 100%.

  Water level reducing: Water level below 100%, App display 75%; below 75%, App show 50%; below 50%, App display 25%, below 25%, App display 0%.

  Normally Relay output 1(terminal 7.8) connects with water pumps, used for controlling water pump on/off.

  Relay output 2 ( terminal 9.10 ) is used for Anti water dry heating protection.

  In add water mode, normally relay output 2(terminal 9,10)can connect with heater, used for auto controlling heater on/off.

  When water level is <; 25%, auto-turn off heater ( relay output 2 ); when water level is 25%, auto-delay 15s to turn on heater ( relay 2 ).

  In pumping water mode, relay 2 is just an alarm output.

  1. Device Name: Can be modified

  2. On/Off Switch of Relay 1: It is only effective when the current water level is between the preset start and stop- water level value.

  3. Display real time water level.

  Five water levels: 0%, 25%, 50%, 75%, 100%

  4. Choose working mode: Adding water or Pumping water.

  5. Set water level value of auto starting/stopping.

  For example: if you want equipment auto-starts to pump water when the water level reaches to 100%, but auto- stop it when the level lower than 25%. You can set pumping mode, level on 100%, level off 25%.

  6. Anti Water Dry heating protection: In adding water mode, auto turn on/off heater. When water level is lower than 25%, auto-turn off relay output 2, when water level is 25%, auto-delay 15s to turn on relay 2.

  7. Enable/disable of alarm notification.

  8,9. Set upper and Lower limit value of water level alarm.

  10. Set delay time of relay 1 starting.

  11. Show current sensor status.

  12. Set limited running time of relay output 1.

  Control Mode 1: Add water

  Water level preset" stop level", relay output 1 disconnect, stop to add water; Water level <; start up level, relay output 1 connects, start to add water.

  Anti Water Dry heating protection: water level <; 25%, relay ouput 2 disconnect, stop heating; Water level 25%, relay output 2 delays 15 seconds connect, start heating.

  Control Mode 2: Pump water

  Water level <; preset " stop level", relay output 1 disconnects, stop to pump water; Water level start up level, relay ouput 1 connects, start to pump water.

  In pumping water mode, relay 2 is an alarm output. Water level preset lower limit alarm value or Water level upper limit alarm value, relay ouput 2 connects.

  Time-limited control

  Mode 3: Time-limited adding water

  Water level <; start up level, relay output 1 connects, starts to add water, at same time, starts the timer. Relay 1 will auto disconnect when it reaches to the preset limited time of running, stop adding water.

  Mode 4: Time-limited pumping

  Water level start up level, relay ouput 1 connects, start to pump water, at same time, starts the timer. Relay 1 will auto disconnect when it reaches to the preset limited time of running, stop pumping water.

  Upper and lower limit Alarm Notification

  For example : Preset alarm lower limit of water level is 25%, alarm upper limit is 75% . When water level is lower than 25% or higher than 75% , it will push alarm notification to users' smartphone via APP.

  Product Show

  Packing List of Default version AC220V

  * One English manual instruction

  * One wifi water level controller

  * Five water level sensors with different cable lenth.

  Remark:

  White cable: 3.5 meters

  Red cable: 3.1 meters

  Yellow cable: 2.3 meters

  Green cable: 1.1 meters

  Blue cable: 1 meter

  If your country is AC110V, no AC220V, please choose the updated version B: DC12V. 

  The DC12V version includes DC12V power adapter, EU/US/UK/AU power plug optional. We will send correct power plug to fit for your country.

  Users can prolong the cable by themself if cable length is no enough. The max cable length that can be extended is 30 meters.

  Specification

  *Size of controller: 89mm x 55mm x 44mm

  *Power voltage: AC220V as default, If your country is 110V, no 220V, please choose the updated version B: DC12V

  *Power consumption: less than 2W

  *Limited running time of relay output 1: 0 to 720 minutes settable via App. Each setting progresses is 5 minutes, 0, 5, 10, 15, .............710, 715, 720

  *Time delay setting of relay output 1:  0 to 30 seconds settable via App.

  *Relay outputs: two relay outputs(normal open)

  The contact current capacity is 10A for resistive load and 2A for inductive load. It can control 2000W resistive load or 500W motor /water pump. Larger loads require AC contactor expansion.

  *Working environment: -10 to +50

  *WIFI 2.4GHZ b/g/n, not support 5G WIFI.

  App WIFI configuration

  The controllers use Tuya smart App or Smart Life App.

  1. Install App

  a. Download Tuya Smart App from google play for android or App store for IOS phone.

  b. Install Tuya Smart App c. Register a new account by e-mail

  2. Login App account

  3. Add device to App via WIFI configuration

                                  

 


 


RETURNS POLICY

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

SHIPPING

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Morbi ut blandit risus. Donec mollis nec tellus et rutrum. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Ut consequat quam a purus faucibus scelerisque. Mauris ac dui ante. Pellentesque congue porttitor tempus. Donec sodales dapibus urna sed dictum. Duis congue posuere libero, a aliquam est porta quis.

Donec ullamcorper magna enim, vitae fermentum turpis elementum quis. Interdum et malesuada fames ac ante ipsum primis in faucibus.

Curabitur vel sem mi. Proin in lobortis ipsum. Aliquam rutrum tempor ex ac rutrum. Maecenas nunc nulla, placerat at eleifend in, viverra etos sem. Nam sagittis lacus metus, dignissim blandit magna euismod eget. Suspendisse a nisl lacus. Phasellus eget augue tincidunt, sollicitudin lectus sed, convallis desto. Pellentesque vitae dui lacinia, venenatis erat sit amet, fringilla felis. Nullam maximus nisi nec mi facilisis.

How to choose the correct size:

Step 1 Please measure your foot length carefully.

Step 2 Please choose the correct size according to your foot length and chinese size.

For example, If your foot length is 255 mm , you should choose the size 8.

Step 3 If you\'re not sure of the correct size, you can click chat with us!

WHATSAPP:+8613625959351

Have Questions?Ask An Expert
Tuya Smart Home Water Level Sensor WIFI Controller Leakage Flood Alarm Swimming Vape Tank Flow Detector System Leak Protection
You have successfully subscribed!